晶圆烘烤用封装电源端子的电-热-结构性能

Dae Seong Woo, Kyoung-Joon Kim
{"title":"晶圆烘烤用封装电源端子的电-热-结构性能","authors":"Dae Seong Woo, Kyoung-Joon Kim","doi":"10.1109/THERMINIC.2017.8233835","DOIUrl":null,"url":null,"abstract":"Failures may often occur in the packaged power terminals (PPTs) of the heater modules during harsh wafer baking process. The dominant failure factor is a high temperature. Hence, the performances of the PPTs should be explored under multiphysics environment to develop robust heater modules. In this study, FEA electrical-thermal-structural models of the PPTs are developed and experimentally validated. Various parametric influences on the thermal and structural performance of PPTs are investigated employing FEA electrical-thermal-structural models. The study has shown that the substrate thickness was a dominant parameter affecting the PPT performance.","PeriodicalId":317847,"journal":{"name":"2017 23rd International Workshop on Thermal Investigations of ICs and Systems (THERMINIC)","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Electrical-thermal-structural performance of packaged power terminals for wafer baking\",\"authors\":\"Dae Seong Woo, Kyoung-Joon Kim\",\"doi\":\"10.1109/THERMINIC.2017.8233835\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Failures may often occur in the packaged power terminals (PPTs) of the heater modules during harsh wafer baking process. The dominant failure factor is a high temperature. Hence, the performances of the PPTs should be explored under multiphysics environment to develop robust heater modules. In this study, FEA electrical-thermal-structural models of the PPTs are developed and experimentally validated. Various parametric influences on the thermal and structural performance of PPTs are investigated employing FEA electrical-thermal-structural models. The study has shown that the substrate thickness was a dominant parameter affecting the PPT performance.\",\"PeriodicalId\":317847,\"journal\":{\"name\":\"2017 23rd International Workshop on Thermal Investigations of ICs and Systems (THERMINIC)\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 23rd International Workshop on Thermal Investigations of ICs and Systems (THERMINIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/THERMINIC.2017.8233835\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 23rd International Workshop on Thermal Investigations of ICs and Systems (THERMINIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/THERMINIC.2017.8233835","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在苛刻的晶圆烘烤过程中,加热模块的封装电源端子(PPTs)经常发生故障。主要的失效因素是高温。因此,在多物理场环境下研究PPTs的性能,以开发健壮的加热器模块。在本研究中,建立了压电陶瓷的电-热-结构有限元模型并进行了实验验证。采用有限元电-热-结构模型研究了各种参数对PPTs热性能和结构性能的影响。研究表明,衬底厚度是影响PPT性能的主要参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electrical-thermal-structural performance of packaged power terminals for wafer baking
Failures may often occur in the packaged power terminals (PPTs) of the heater modules during harsh wafer baking process. The dominant failure factor is a high temperature. Hence, the performances of the PPTs should be explored under multiphysics environment to develop robust heater modules. In this study, FEA electrical-thermal-structural models of the PPTs are developed and experimentally validated. Various parametric influences on the thermal and structural performance of PPTs are investigated employing FEA electrical-thermal-structural models. The study has shown that the substrate thickness was a dominant parameter affecting the PPT performance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信