{"title":"基于有机硅氧烷超分子聚合物的CO2检测器","authors":"G. Ţelipan, L. Pîslaru-Dănescu, C. Racles","doi":"10.1109/ESTC.2008.4684529","DOIUrl":null,"url":null,"abstract":"The sensor was made by thick and thin film technology. An alumina substrate 6times6times0.5 mm was used. On the substrate was screen-printed an interdigitated electrode array by Au conductive ink. The sensitive layer the organo-siloxane supramolecular polymers was dissolved in chloroform and was deposed by spin coating on the substrate over electrode in the 200 nm thickness. The sensor was tested in 100 and 1000 ppm concentration CO2 and for 30 minutes gas exposure were obtained the voltage values of 92 mV and 970 mV for 100 ppm and 1000 ppm CO2. The detector is composed by the sensor and electronic device of signal conditioning.","PeriodicalId":146584,"journal":{"name":"2008 2nd Electronics System-Integration Technology Conference","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"CO2 detector based on organo-siloxane supramolecular polymer\",\"authors\":\"G. Ţelipan, L. Pîslaru-Dănescu, C. Racles\",\"doi\":\"10.1109/ESTC.2008.4684529\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The sensor was made by thick and thin film technology. An alumina substrate 6times6times0.5 mm was used. On the substrate was screen-printed an interdigitated electrode array by Au conductive ink. The sensitive layer the organo-siloxane supramolecular polymers was dissolved in chloroform and was deposed by spin coating on the substrate over electrode in the 200 nm thickness. The sensor was tested in 100 and 1000 ppm concentration CO2 and for 30 minutes gas exposure were obtained the voltage values of 92 mV and 970 mV for 100 ppm and 1000 ppm CO2. The detector is composed by the sensor and electronic device of signal conditioning.\",\"PeriodicalId\":146584,\"journal\":{\"name\":\"2008 2nd Electronics System-Integration Technology Conference\",\"volume\":\"49 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-11-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 2nd Electronics System-Integration Technology Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ESTC.2008.4684529\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 2nd Electronics System-Integration Technology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESTC.2008.4684529","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
CO2 detector based on organo-siloxane supramolecular polymer
The sensor was made by thick and thin film technology. An alumina substrate 6times6times0.5 mm was used. On the substrate was screen-printed an interdigitated electrode array by Au conductive ink. The sensitive layer the organo-siloxane supramolecular polymers was dissolved in chloroform and was deposed by spin coating on the substrate over electrode in the 200 nm thickness. The sensor was tested in 100 and 1000 ppm concentration CO2 and for 30 minutes gas exposure were obtained the voltage values of 92 mV and 970 mV for 100 ppm and 1000 ppm CO2. The detector is composed by the sensor and electronic device of signal conditioning.