生物可降解涂层对神经装置用聚酰亚胺基探针刚度控制的评价

K. Tan, Weiguo Chen, Ramona B. Damalerio, Ruiqi Lim, S. Chungpaiboonpatana, Ming-Yuan Cheng
{"title":"生物可降解涂层对神经装置用聚酰亚胺基探针刚度控制的评价","authors":"K. Tan, Weiguo Chen, Ramona B. Damalerio, Ruiqi Lim, S. Chungpaiboonpatana, Ming-Yuan Cheng","doi":"10.1109/EPTC.2015.7412287","DOIUrl":null,"url":null,"abstract":"In this work, an assembled and integrated flexible probe array with biodegradable coating for stiffness control is demonstrated. The proposed method will help to overcome the stiffness issue faced by polymeric probe array during insertion into the brain tissue. It is proposed to do coating with biodegradable material to increase the stiffness of the probe shanks. Assembly process is simplified as polymer probe and cable were being monolithically fabricated, only the connector needs to be soldered onto the bonding pads. To enhance the soldering between connector and bonding pads, rigid stiffener is designed at the bonding pads region to provide robust support for soldering process and for insertion process.","PeriodicalId":418705,"journal":{"name":"2015 IEEE 17th Electronics Packaging and Technology Conference (EPTC)","volume":"17 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Evaluation of biodegradable coating on the stiffness control of the polyimide-based probe used in neural devices\",\"authors\":\"K. Tan, Weiguo Chen, Ramona B. Damalerio, Ruiqi Lim, S. Chungpaiboonpatana, Ming-Yuan Cheng\",\"doi\":\"10.1109/EPTC.2015.7412287\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work, an assembled and integrated flexible probe array with biodegradable coating for stiffness control is demonstrated. The proposed method will help to overcome the stiffness issue faced by polymeric probe array during insertion into the brain tissue. It is proposed to do coating with biodegradable material to increase the stiffness of the probe shanks. Assembly process is simplified as polymer probe and cable were being monolithically fabricated, only the connector needs to be soldered onto the bonding pads. To enhance the soldering between connector and bonding pads, rigid stiffener is designed at the bonding pads region to provide robust support for soldering process and for insertion process.\",\"PeriodicalId\":418705,\"journal\":{\"name\":\"2015 IEEE 17th Electronics Packaging and Technology Conference (EPTC)\",\"volume\":\"17 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE 17th Electronics Packaging and Technology Conference (EPTC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPTC.2015.7412287\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE 17th Electronics Packaging and Technology Conference (EPTC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPTC.2015.7412287","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在这项工作中,展示了一种装配和集成的柔性探针阵列,其生物可降解涂层用于刚度控制。所提出的方法将有助于克服聚合物探针阵列在插入脑组织时所面临的僵硬问题。建议用生物可降解材料进行涂层,以增加探针柄的刚度。由于聚合物探头和电缆是整体制造,因此简化了组装过程,只需要将连接器焊接到焊盘上。为了加强连接器与焊盘之间的焊接,在焊盘区域设计了刚性加强板,为焊接过程和插入过程提供坚固的支撑。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of biodegradable coating on the stiffness control of the polyimide-based probe used in neural devices
In this work, an assembled and integrated flexible probe array with biodegradable coating for stiffness control is demonstrated. The proposed method will help to overcome the stiffness issue faced by polymeric probe array during insertion into the brain tissue. It is proposed to do coating with biodegradable material to increase the stiffness of the probe shanks. Assembly process is simplified as polymer probe and cable were being monolithically fabricated, only the connector needs to be soldered onto the bonding pads. To enhance the soldering between connector and bonding pads, rigid stiffener is designed at the bonding pads region to provide robust support for soldering process and for insertion process.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信