减小插入力连接器设计中的力和几何参数优化

I. Sawchyn, E. S. Sproles
{"title":"减小插入力连接器设计中的力和几何参数优化","authors":"I. Sawchyn, E. S. Sproles","doi":"10.1109/ECTC.1992.204219","DOIUrl":null,"url":null,"abstract":"The need to design connectors with large numbers of I/Os is hindered by the associated rise in connector insertion force. It is possible to lower an undesirably high insertion force by reducing the normal force of the contacts, but this raises the question of whether reduced-normal force connectors are sufficiently reliable for telecommunications applications. The authors examined nine test connector designs fabricated with 150-, 75- and 35-g nominal contact normal force, and with 150-, 70-, and 35-mil radii at the point of contact with the pin. The connectors were exposed to conditions of thermal stress (thermal aging and thermal cycling), atmospheric corrosion, and extreme dust contamination coupled with thermal/humidity exposure. Precision resistance measurements were made at various times before, during, and after exposures. All nine designs performed reliably under the test conditions used in this study. The results suggest that connectors which are designed with contact geometries that provide higher local pressures are more effective in overcoming the interference of the dust contamination.<<ETX>>","PeriodicalId":125270,"journal":{"name":"1992 Proceedings 42nd Electronic Components & Technology Conference","volume":"43 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-05-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":"{\"title\":\"Optimizing force and geometry parameters in design of reduced-insertion force connectors\",\"authors\":\"I. Sawchyn, E. S. Sproles\",\"doi\":\"10.1109/ECTC.1992.204219\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The need to design connectors with large numbers of I/Os is hindered by the associated rise in connector insertion force. It is possible to lower an undesirably high insertion force by reducing the normal force of the contacts, but this raises the question of whether reduced-normal force connectors are sufficiently reliable for telecommunications applications. The authors examined nine test connector designs fabricated with 150-, 75- and 35-g nominal contact normal force, and with 150-, 70-, and 35-mil radii at the point of contact with the pin. The connectors were exposed to conditions of thermal stress (thermal aging and thermal cycling), atmospheric corrosion, and extreme dust contamination coupled with thermal/humidity exposure. Precision resistance measurements were made at various times before, during, and after exposures. All nine designs performed reliably under the test conditions used in this study. The results suggest that connectors which are designed with contact geometries that provide higher local pressures are more effective in overcoming the interference of the dust contamination.<<ETX>>\",\"PeriodicalId\":125270,\"journal\":{\"name\":\"1992 Proceedings 42nd Electronic Components & Technology Conference\",\"volume\":\"43 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-05-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1992 Proceedings 42nd Electronic Components & Technology Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECTC.1992.204219\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1992 Proceedings 42nd Electronic Components & Technology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECTC.1992.204219","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

连接器插入力的增加阻碍了设计具有大量I/ o的连接器的需求。可以通过减小触点的法向力来降低不希望的高插入力,但这就提出了一个问题,即减小法向力的连接器是否足够可靠,适用于电信应用。作者研究了9种测试连接器设计,分别采用150,75和35g标称接触法向力,以及150,70和35mil与引脚接触点的半径。连接器暴露在热应力(热老化和热循环)、大气腐蚀和极端灰尘污染以及热/湿暴露的条件下。在曝光之前、期间和之后的不同时间进行了精确的电阻测量。在本研究中使用的测试条件下,所有九种设计都可靠地执行。结果表明,设计具有提供较高局部压力的接触几何形状的连接器在克服粉尘污染的干扰方面更有效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Optimizing force and geometry parameters in design of reduced-insertion force connectors
The need to design connectors with large numbers of I/Os is hindered by the associated rise in connector insertion force. It is possible to lower an undesirably high insertion force by reducing the normal force of the contacts, but this raises the question of whether reduced-normal force connectors are sufficiently reliable for telecommunications applications. The authors examined nine test connector designs fabricated with 150-, 75- and 35-g nominal contact normal force, and with 150-, 70-, and 35-mil radii at the point of contact with the pin. The connectors were exposed to conditions of thermal stress (thermal aging and thermal cycling), atmospheric corrosion, and extreme dust contamination coupled with thermal/humidity exposure. Precision resistance measurements were made at various times before, during, and after exposures. All nine designs performed reliably under the test conditions used in this study. The results suggest that connectors which are designed with contact geometries that provide higher local pressures are more effective in overcoming the interference of the dust contamination.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信