{"title":"在微流通道中形成的液体塞中分析物的库仑法检测","authors":"F. Sassa, H. Laghzali, J. Fukuda, H. Suzuki","doi":"10.1109/SENSOR.2009.5285975","DOIUrl":null,"url":null,"abstract":"Applicability of coulometric detection was tested for the analysis of an analyte in a liquid plug confined in a PDMS microflow channel. A plug prepared in the flow channel was placed on a three-electrode system and hydrogen peroxide was detected. With plugs of a small volume, the depletion of the analyte was rapid, making reproducible amperometric detection difficult particularly when the flow channel was shallow. On the other hand, coulometric detection showed a clear relationship between the generated charge and the concentration. However, when the volume of the plug was large, only a part of the analyte was used for detection, suggesting the possibility to improve the detection sensitivity further. The device was also tested in the detection of L-glutamate.","PeriodicalId":247826,"journal":{"name":"TRANSDUCERS 2009 - 2009 International Solid-State Sensors, Actuators and Microsystems Conference","volume":"76 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Coulometric detection of an analyte in a liquid plug formed in a microflow channel\",\"authors\":\"F. Sassa, H. Laghzali, J. Fukuda, H. Suzuki\",\"doi\":\"10.1109/SENSOR.2009.5285975\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Applicability of coulometric detection was tested for the analysis of an analyte in a liquid plug confined in a PDMS microflow channel. A plug prepared in the flow channel was placed on a three-electrode system and hydrogen peroxide was detected. With plugs of a small volume, the depletion of the analyte was rapid, making reproducible amperometric detection difficult particularly when the flow channel was shallow. On the other hand, coulometric detection showed a clear relationship between the generated charge and the concentration. However, when the volume of the plug was large, only a part of the analyte was used for detection, suggesting the possibility to improve the detection sensitivity further. The device was also tested in the detection of L-glutamate.\",\"PeriodicalId\":247826,\"journal\":{\"name\":\"TRANSDUCERS 2009 - 2009 International Solid-State Sensors, Actuators and Microsystems Conference\",\"volume\":\"76 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-06-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"TRANSDUCERS 2009 - 2009 International Solid-State Sensors, Actuators and Microsystems Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SENSOR.2009.5285975\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"TRANSDUCERS 2009 - 2009 International Solid-State Sensors, Actuators and Microsystems Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SENSOR.2009.5285975","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Coulometric detection of an analyte in a liquid plug formed in a microflow channel
Applicability of coulometric detection was tested for the analysis of an analyte in a liquid plug confined in a PDMS microflow channel. A plug prepared in the flow channel was placed on a three-electrode system and hydrogen peroxide was detected. With plugs of a small volume, the depletion of the analyte was rapid, making reproducible amperometric detection difficult particularly when the flow channel was shallow. On the other hand, coulometric detection showed a clear relationship between the generated charge and the concentration. However, when the volume of the plug was large, only a part of the analyte was used for detection, suggesting the possibility to improve the detection sensitivity further. The device was also tested in the detection of L-glutamate.