快速SAR测量的均匀体场分布建模

O. Merckel, J. Bolomey, G. Fleury
{"title":"快速SAR测量的均匀体场分布建模","authors":"O. Merckel, J. Bolomey, G. Fleury","doi":"10.1109/ICSMC2.2003.1428227","DOIUrl":null,"url":null,"abstract":"Specific absorption rate (SAR) designates the electromagnetic power density deposited per unit mass of biological tissue. SAR measurements are required to assess the compliance of mobile phones with existing standards and recommendations. The use of homogeneous phantoms leads to a relatively simple distribution of the electric field. Several ways of determining the decrease of the electric field in function of depth are here explored. The choice of a pseudopropagation constant allows to drastically reduce the number of E-field measurement points needed for the SAR calculation. The measurement time is then reduced to less than a minute, while the standard way takes about 10 minutes for a complete measurement of almost thousand E-field data points","PeriodicalId":272545,"journal":{"name":"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.","volume":"221 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"E-field distribution modeling in a homogeneous phantom for a rapid SAR measurement\",\"authors\":\"O. Merckel, J. Bolomey, G. Fleury\",\"doi\":\"10.1109/ICSMC2.2003.1428227\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Specific absorption rate (SAR) designates the electromagnetic power density deposited per unit mass of biological tissue. SAR measurements are required to assess the compliance of mobile phones with existing standards and recommendations. The use of homogeneous phantoms leads to a relatively simple distribution of the electric field. Several ways of determining the decrease of the electric field in function of depth are here explored. The choice of a pseudopropagation constant allows to drastically reduce the number of E-field measurement points needed for the SAR calculation. The measurement time is then reduced to less than a minute, while the standard way takes about 10 minutes for a complete measurement of almost thousand E-field data points\",\"PeriodicalId\":272545,\"journal\":{\"name\":\"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.\",\"volume\":\"221 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSMC2.2003.1428227\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 IEEE International Symposium on Electromagnetic Compatibility, 2003. EMC '03.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSMC2.2003.1428227","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

比吸收率(SAR)表示每单位质量生物组织沉积的电磁功率密度。需要进行SAR测量,以评估流动电话是否符合现行标准和建议。均匀幻像的使用使得电场的分布相对简单。本文探讨了确定电场衰减随深度变化的几种方法。伪传播常数的选择可以大大减少SAR计算所需的e场测量点的数量。然后测量时间减少到不到一分钟,而标准方法需要大约10分钟才能完成近千场数据点的测量
本文章由计算机程序翻译,如有差异,请以英文原文为准。
E-field distribution modeling in a homogeneous phantom for a rapid SAR measurement
Specific absorption rate (SAR) designates the electromagnetic power density deposited per unit mass of biological tissue. SAR measurements are required to assess the compliance of mobile phones with existing standards and recommendations. The use of homogeneous phantoms leads to a relatively simple distribution of the electric field. Several ways of determining the decrease of the electric field in function of depth are here explored. The choice of a pseudopropagation constant allows to drastically reduce the number of E-field measurement points needed for the SAR calculation. The measurement time is then reduced to less than a minute, while the standard way takes about 10 minutes for a complete measurement of almost thousand E-field data points
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信