{"title":"热管理使用“干”相变材料","authors":"R. Wirtz, N. Zheng, D. Chandra","doi":"10.1109/STHERM.1999.762432","DOIUrl":null,"url":null,"abstract":"The thermal response characteristic of a hybrid cooler that is charged with a \"dry\" solid-solid phase change compound is evaluated. A mathematical model that simulates the performance of a cooler/heat storage unit is formulated. A prototype heat sink that incorporates heat storage using a \"dry\" PCM is tested, and used to benchmark the simulation model. Different heating and cooling strategies are evaluated and a figure of merit characteristic of the cooler/PCM under development is introduced.","PeriodicalId":253023,"journal":{"name":"Fifteenth Annual IEEE Semiconductor Thermal Measurement and Management Symposium (Cat. No.99CH36306)","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-03-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"38","resultStr":"{\"title\":\"Thermal management using \\\"dry\\\" phase change material\",\"authors\":\"R. Wirtz, N. Zheng, D. Chandra\",\"doi\":\"10.1109/STHERM.1999.762432\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The thermal response characteristic of a hybrid cooler that is charged with a \\\"dry\\\" solid-solid phase change compound is evaluated. A mathematical model that simulates the performance of a cooler/heat storage unit is formulated. A prototype heat sink that incorporates heat storage using a \\\"dry\\\" PCM is tested, and used to benchmark the simulation model. Different heating and cooling strategies are evaluated and a figure of merit characteristic of the cooler/PCM under development is introduced.\",\"PeriodicalId\":253023,\"journal\":{\"name\":\"Fifteenth Annual IEEE Semiconductor Thermal Measurement and Management Symposium (Cat. No.99CH36306)\",\"volume\":\"7 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-03-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"38\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fifteenth Annual IEEE Semiconductor Thermal Measurement and Management Symposium (Cat. No.99CH36306)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/STHERM.1999.762432\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fifteenth Annual IEEE Semiconductor Thermal Measurement and Management Symposium (Cat. No.99CH36306)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/STHERM.1999.762432","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Thermal management using "dry" phase change material
The thermal response characteristic of a hybrid cooler that is charged with a "dry" solid-solid phase change compound is evaluated. A mathematical model that simulates the performance of a cooler/heat storage unit is formulated. A prototype heat sink that incorporates heat storage using a "dry" PCM is tested, and used to benchmark the simulation model. Different heating and cooling strategies are evaluated and a figure of merit characteristic of the cooler/PCM under development is introduced.