一种表征由包装过程引起的热机械应力的方法的应用

S. Majcherek, S. Hirsch
{"title":"一种表征由包装过程引起的热机械应力的方法的应用","authors":"S. Majcherek, S. Hirsch","doi":"10.1109/ESTC.2008.4684477","DOIUrl":null,"url":null,"abstract":"This paper reports on a method for the investigation of mechanical stress on MEMS sensor and actuator structures due to packaging processes. A silicon test chip is developed and manufactured to validate the simulation results. Finite element analysis (FEA) is used to optimize the geometric parameters and to find a stress sensitive sensor geometry. A diaphragm structure is used as mechanical amplifier for bulk induced stresses during the packaging process. Piezo resistive solid state resistors are doped into the surface of the chip to measure the stress in the diaphragms and at the contact pads being most significant locations for analysis. A high precision ohmmeter was used to measure the resistance prior and past the packaging process. The captured data allows for computation of the resulting stress loads in magnitude. Therefore, a stress evaluation of different packaging technologies is conducted and the impact of the packaging process on reliability can be estimated immediately.","PeriodicalId":146584,"journal":{"name":"2008 2nd Electronics System-Integration Technology Conference","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Application of a method for characterization of thermo mechanical stress caused by packaging processes\",\"authors\":\"S. Majcherek, S. Hirsch\",\"doi\":\"10.1109/ESTC.2008.4684477\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper reports on a method for the investigation of mechanical stress on MEMS sensor and actuator structures due to packaging processes. A silicon test chip is developed and manufactured to validate the simulation results. Finite element analysis (FEA) is used to optimize the geometric parameters and to find a stress sensitive sensor geometry. A diaphragm structure is used as mechanical amplifier for bulk induced stresses during the packaging process. Piezo resistive solid state resistors are doped into the surface of the chip to measure the stress in the diaphragms and at the contact pads being most significant locations for analysis. A high precision ohmmeter was used to measure the resistance prior and past the packaging process. The captured data allows for computation of the resulting stress loads in magnitude. Therefore, a stress evaluation of different packaging technologies is conducted and the impact of the packaging process on reliability can be estimated immediately.\",\"PeriodicalId\":146584,\"journal\":{\"name\":\"2008 2nd Electronics System-Integration Technology Conference\",\"volume\":\"21 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-11-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 2nd Electronics System-Integration Technology Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ESTC.2008.4684477\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 2nd Electronics System-Integration Technology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESTC.2008.4684477","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

本文报道了一种研究MEMS传感器和致动器结构因封装过程而产生的机械应力的方法。研制了硅片测试芯片,对仿真结果进行了验证。采用有限元分析(FEA)优化几何参数,寻找应力敏感传感器的几何形状。在包装过程中,膜片结构用作机械放大器来处理大块诱导应力。将压阻式固态电阻器掺杂到芯片表面,测量膜片和触点处的应力,这是分析中最重要的位置。采用高精度欧姆计测量封装前和封装后的电阻。捕获的数据允许计算由此产生的应力载荷的大小。因此,对不同的封装工艺进行应力评估,可以立即估计封装工艺对可靠性的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Application of a method for characterization of thermo mechanical stress caused by packaging processes
This paper reports on a method for the investigation of mechanical stress on MEMS sensor and actuator structures due to packaging processes. A silicon test chip is developed and manufactured to validate the simulation results. Finite element analysis (FEA) is used to optimize the geometric parameters and to find a stress sensitive sensor geometry. A diaphragm structure is used as mechanical amplifier for bulk induced stresses during the packaging process. Piezo resistive solid state resistors are doped into the surface of the chip to measure the stress in the diaphragms and at the contact pads being most significant locations for analysis. A high precision ohmmeter was used to measure the resistance prior and past the packaging process. The captured data allows for computation of the resulting stress loads in magnitude. Therefore, a stress evaluation of different packaging technologies is conducted and the impact of the packaging process on reliability can be estimated immediately.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信