{"title":"陶瓷多芯片模块的热管理:实验程序","authors":"G. Kromann","doi":"10.1109/MCMC.1992.201451","DOIUrl":null,"url":null,"abstract":"The author describes the thermal characterization of an alumina-tungsten multilayer multichip module (MCM). A five-chip cavity-down MCM was designed to represent a typical substrate product. Thermal test multichip modules were assembled and the thermal performance quantified for both the internal and the external thermal resistances. The die junction-to-ambient resistance was measured in forced-air convection for the range of 1 to 5 m/s, for: (1) two pin-fin heat sinks, (2) a thermoelectric cooler with a pin-fin heat sink, and (3) a heat pipe with an integral extended surface. In addition, the run-to-run and the part-to-part variations, are presented. A discussion on the thermal management concepts and the heat transfer applicable to the MCM technology is included.<<ETX>>","PeriodicalId":202574,"journal":{"name":"Proceedings 1992 IEEE Multi-Chip Module Conference MCMC-92","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"Thermal management for ceramic multichip modules: experimental program\",\"authors\":\"G. Kromann\",\"doi\":\"10.1109/MCMC.1992.201451\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The author describes the thermal characterization of an alumina-tungsten multilayer multichip module (MCM). A five-chip cavity-down MCM was designed to represent a typical substrate product. Thermal test multichip modules were assembled and the thermal performance quantified for both the internal and the external thermal resistances. The die junction-to-ambient resistance was measured in forced-air convection for the range of 1 to 5 m/s, for: (1) two pin-fin heat sinks, (2) a thermoelectric cooler with a pin-fin heat sink, and (3) a heat pipe with an integral extended surface. In addition, the run-to-run and the part-to-part variations, are presented. A discussion on the thermal management concepts and the heat transfer applicable to the MCM technology is included.<<ETX>>\",\"PeriodicalId\":202574,\"journal\":{\"name\":\"Proceedings 1992 IEEE Multi-Chip Module Conference MCMC-92\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-03-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings 1992 IEEE Multi-Chip Module Conference MCMC-92\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MCMC.1992.201451\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings 1992 IEEE Multi-Chip Module Conference MCMC-92","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MCMC.1992.201451","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Thermal management for ceramic multichip modules: experimental program
The author describes the thermal characterization of an alumina-tungsten multilayer multichip module (MCM). A five-chip cavity-down MCM was designed to represent a typical substrate product. Thermal test multichip modules were assembled and the thermal performance quantified for both the internal and the external thermal resistances. The die junction-to-ambient resistance was measured in forced-air convection for the range of 1 to 5 m/s, for: (1) two pin-fin heat sinks, (2) a thermoelectric cooler with a pin-fin heat sink, and (3) a heat pipe with an integral extended surface. In addition, the run-to-run and the part-to-part variations, are presented. A discussion on the thermal management concepts and the heat transfer applicable to the MCM technology is included.<>