陶瓷多芯片模块的热管理:实验程序

G. Kromann
{"title":"陶瓷多芯片模块的热管理:实验程序","authors":"G. Kromann","doi":"10.1109/MCMC.1992.201451","DOIUrl":null,"url":null,"abstract":"The author describes the thermal characterization of an alumina-tungsten multilayer multichip module (MCM). A five-chip cavity-down MCM was designed to represent a typical substrate product. Thermal test multichip modules were assembled and the thermal performance quantified for both the internal and the external thermal resistances. The die junction-to-ambient resistance was measured in forced-air convection for the range of 1 to 5 m/s, for: (1) two pin-fin heat sinks, (2) a thermoelectric cooler with a pin-fin heat sink, and (3) a heat pipe with an integral extended surface. In addition, the run-to-run and the part-to-part variations, are presented. A discussion on the thermal management concepts and the heat transfer applicable to the MCM technology is included.<<ETX>>","PeriodicalId":202574,"journal":{"name":"Proceedings 1992 IEEE Multi-Chip Module Conference MCMC-92","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"Thermal management for ceramic multichip modules: experimental program\",\"authors\":\"G. Kromann\",\"doi\":\"10.1109/MCMC.1992.201451\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The author describes the thermal characterization of an alumina-tungsten multilayer multichip module (MCM). A five-chip cavity-down MCM was designed to represent a typical substrate product. Thermal test multichip modules were assembled and the thermal performance quantified for both the internal and the external thermal resistances. The die junction-to-ambient resistance was measured in forced-air convection for the range of 1 to 5 m/s, for: (1) two pin-fin heat sinks, (2) a thermoelectric cooler with a pin-fin heat sink, and (3) a heat pipe with an integral extended surface. In addition, the run-to-run and the part-to-part variations, are presented. A discussion on the thermal management concepts and the heat transfer applicable to the MCM technology is included.<<ETX>>\",\"PeriodicalId\":202574,\"journal\":{\"name\":\"Proceedings 1992 IEEE Multi-Chip Module Conference MCMC-92\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-03-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings 1992 IEEE Multi-Chip Module Conference MCMC-92\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MCMC.1992.201451\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings 1992 IEEE Multi-Chip Module Conference MCMC-92","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MCMC.1992.201451","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

介绍了一种铝钨多层多芯片模块(MCM)的热特性。设计了一种典型的五芯片空腔MCM。组装了热测试多芯片模块,并对内部和外部热阻进行了热性能量化。在强制空气对流中,在1 ~ 5m /s范围内测量了模具结对环境的阻力,其中:(1)两个针翅式散热器,(2)带有针翅式散热器的热电冷却器,以及(3)具有积分扩展表面的热管。此外,还介绍了运行间和部件间的变化。讨论了适用于MCM技术的热管理概念和传热问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Thermal management for ceramic multichip modules: experimental program
The author describes the thermal characterization of an alumina-tungsten multilayer multichip module (MCM). A five-chip cavity-down MCM was designed to represent a typical substrate product. Thermal test multichip modules were assembled and the thermal performance quantified for both the internal and the external thermal resistances. The die junction-to-ambient resistance was measured in forced-air convection for the range of 1 to 5 m/s, for: (1) two pin-fin heat sinks, (2) a thermoelectric cooler with a pin-fin heat sink, and (3) a heat pipe with an integral extended surface. In addition, the run-to-run and the part-to-part variations, are presented. A discussion on the thermal management concepts and the heat transfer applicable to the MCM technology is included.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信