研究了不同氯含量模塑化合物中银合金焊丝在铝衬垫上的腐蚀行为

Y. Chiu, Tzu-Hsing Chiang, Ping-Feng Yang, Louie Huang, C. Hung, S. Uegaki, Kwang-Lung Lin
{"title":"研究了不同氯含量模塑化合物中银合金焊丝在铝衬垫上的腐蚀行为","authors":"Y. Chiu, Tzu-Hsing Chiang, Ping-Feng Yang, Louie Huang, C. Hung, S. Uegaki, Kwang-Lung Lin","doi":"10.1109/ICEP.2016.7486877","DOIUrl":null,"url":null,"abstract":"The present article investigated the performance and corrosion behavior between Ag alloy wire bond and Al pad under molding compounds of different chlorine contents. The epoxy molding compounds (EMCs) were categorized as ultra-high chlorine, high chlorine and low chlorine, respectively, with 18.3 and 4.1 ppm chlorine contents. The ball bonds were stressed under 130°C/85%RH with biased voltage of 10V. The interfacial evolution between Ag alloy wire bond and Al pad was investigated in EMC of three chlorine contents after the biased-HAST test. The Ag bonding wires used in the plastic ball grid array (PBGA) package include low Ag wire (89wt%) and high Ag alloy wire (97wt%). The as bonded wire bond exhibits an average Ag-Al IMC thickness of ~0.56 μm in both types of Ag alloy wire. Two Cu-Al IMC layers, AgAl2 and Ag4Al, analyzed by EDX were formed after 96h of biased-HAST test. The joint failed in 96h and 480h, respectively, under high chlorine content EMC. The joint lasts longer than 1056h with low chlorine content EMC. The corrosion of IMC formed between Ag alloy wire and Al pad, occurs in the high Ag content alloy wire. The results of EDX analysis indicate that the chlorine ion diffuses from molding compound to IMC through the crack formed between IMC and Al pad. Al2O3 was formed within the IMC layer. It is believed the existence of Al2O3 accelerates the penetration of the chlorine ion and thus the corrosion.","PeriodicalId":343912,"journal":{"name":"2016 International Conference on Electronics Packaging (ICEP)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-04-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"The corrosion behavior of Ag alloy wire bond on Al pad in molding compounds of various chlorine contents under biased-HAST\",\"authors\":\"Y. Chiu, Tzu-Hsing Chiang, Ping-Feng Yang, Louie Huang, C. Hung, S. Uegaki, Kwang-Lung Lin\",\"doi\":\"10.1109/ICEP.2016.7486877\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The present article investigated the performance and corrosion behavior between Ag alloy wire bond and Al pad under molding compounds of different chlorine contents. The epoxy molding compounds (EMCs) were categorized as ultra-high chlorine, high chlorine and low chlorine, respectively, with 18.3 and 4.1 ppm chlorine contents. The ball bonds were stressed under 130°C/85%RH with biased voltage of 10V. The interfacial evolution between Ag alloy wire bond and Al pad was investigated in EMC of three chlorine contents after the biased-HAST test. The Ag bonding wires used in the plastic ball grid array (PBGA) package include low Ag wire (89wt%) and high Ag alloy wire (97wt%). The as bonded wire bond exhibits an average Ag-Al IMC thickness of ~0.56 μm in both types of Ag alloy wire. Two Cu-Al IMC layers, AgAl2 and Ag4Al, analyzed by EDX were formed after 96h of biased-HAST test. The joint failed in 96h and 480h, respectively, under high chlorine content EMC. The joint lasts longer than 1056h with low chlorine content EMC. The corrosion of IMC formed between Ag alloy wire and Al pad, occurs in the high Ag content alloy wire. The results of EDX analysis indicate that the chlorine ion diffuses from molding compound to IMC through the crack formed between IMC and Al pad. Al2O3 was formed within the IMC layer. It is believed the existence of Al2O3 accelerates the penetration of the chlorine ion and thus the corrosion.\",\"PeriodicalId\":343912,\"journal\":{\"name\":\"2016 International Conference on Electronics Packaging (ICEP)\",\"volume\":\"33 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-04-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 International Conference on Electronics Packaging (ICEP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEP.2016.7486877\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 International Conference on Electronics Packaging (ICEP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEP.2016.7486877","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

本文研究了不同氯含量的模塑化合物对银合金焊丝与铝焊盘的腐蚀性能和腐蚀行为。环氧成型化合物(EMCs)的氯含量分别为18.3 ppm和4.1 ppm,分为超高氯、高氯和低氯三类。在130°C/85%RH和10V偏置电压下对球键进行应力处理。通过偏置hast试验,研究了三种氯含量的电磁相容性条件下银合金焊丝与Al衬垫之间的界面演化。塑料球栅阵列(PBGA)封装中使用的银键合线包括低银线(89wt%)和高银合金线(97wt%)。在两种类型的Ag合金丝中,as键合线的平均Ag- al IMC厚度为~0.56 μm。经过96小时的偏置hast测试,EDX分析了两个Cu-Al IMC层AgAl2和Ag4Al。在高氯含量EMC下,接头分别在96h和480h失效。接头寿命大于1056h,氯含量低EMC。银合金丝与Al焊盘之间形成的IMC腐蚀主要发生在含银量高的合金丝中。EDX分析结果表明,氯离子通过IMC与Al衬垫之间形成的裂纹从成型化合物扩散到IMC。Al2O3在IMC层内形成。认为Al2O3的存在加速了氯离子的渗透,从而加速了腐蚀。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The corrosion behavior of Ag alloy wire bond on Al pad in molding compounds of various chlorine contents under biased-HAST
The present article investigated the performance and corrosion behavior between Ag alloy wire bond and Al pad under molding compounds of different chlorine contents. The epoxy molding compounds (EMCs) were categorized as ultra-high chlorine, high chlorine and low chlorine, respectively, with 18.3 and 4.1 ppm chlorine contents. The ball bonds were stressed under 130°C/85%RH with biased voltage of 10V. The interfacial evolution between Ag alloy wire bond and Al pad was investigated in EMC of three chlorine contents after the biased-HAST test. The Ag bonding wires used in the plastic ball grid array (PBGA) package include low Ag wire (89wt%) and high Ag alloy wire (97wt%). The as bonded wire bond exhibits an average Ag-Al IMC thickness of ~0.56 μm in both types of Ag alloy wire. Two Cu-Al IMC layers, AgAl2 and Ag4Al, analyzed by EDX were formed after 96h of biased-HAST test. The joint failed in 96h and 480h, respectively, under high chlorine content EMC. The joint lasts longer than 1056h with low chlorine content EMC. The corrosion of IMC formed between Ag alloy wire and Al pad, occurs in the high Ag content alloy wire. The results of EDX analysis indicate that the chlorine ion diffuses from molding compound to IMC through the crack formed between IMC and Al pad. Al2O3 was formed within the IMC layer. It is believed the existence of Al2O3 accelerates the penetration of the chlorine ion and thus the corrosion.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信