{"title":"双引线驱动多控制器的调频速度控制","authors":"M. Nokata, K. Ikuta","doi":"10.1109/MHS.1999.819992","DOIUrl":null,"url":null,"abstract":"A new concept for an active endoscope with hyper redundancy has been already proposed. This medical tool called \"Hyper Endoscope\" for minimally invasive surgery is driven by miniature cybernetic actuators. A dynamic model of the cybernetic actuator, taking into account its piezoelectric effect, is proposed and its detailed performance analyzed. Based on the result, a new technique to minimize the number of lead wires is proposed and verified experimentally. FMVC (Frequency Modulation Velocity Control) with two lead wires as an analog control method has been perfected.","PeriodicalId":423453,"journal":{"name":"MHS'99. Proceedings of 1999 International Symposium on Micromechatronics and Human Science (Cat. No.99TH8478)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1999-11-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Frequency modulation velocity control of multiple cybernetic actuators for two-lead-wire drive\",\"authors\":\"M. Nokata, K. Ikuta\",\"doi\":\"10.1109/MHS.1999.819992\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new concept for an active endoscope with hyper redundancy has been already proposed. This medical tool called \\\"Hyper Endoscope\\\" for minimally invasive surgery is driven by miniature cybernetic actuators. A dynamic model of the cybernetic actuator, taking into account its piezoelectric effect, is proposed and its detailed performance analyzed. Based on the result, a new technique to minimize the number of lead wires is proposed and verified experimentally. FMVC (Frequency Modulation Velocity Control) with two lead wires as an analog control method has been perfected.\",\"PeriodicalId\":423453,\"journal\":{\"name\":\"MHS'99. Proceedings of 1999 International Symposium on Micromechatronics and Human Science (Cat. No.99TH8478)\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-11-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"MHS'99. Proceedings of 1999 International Symposium on Micromechatronics and Human Science (Cat. No.99TH8478)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MHS.1999.819992\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"MHS'99. Proceedings of 1999 International Symposium on Micromechatronics and Human Science (Cat. No.99TH8478)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MHS.1999.819992","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Frequency modulation velocity control of multiple cybernetic actuators for two-lead-wire drive
A new concept for an active endoscope with hyper redundancy has been already proposed. This medical tool called "Hyper Endoscope" for minimally invasive surgery is driven by miniature cybernetic actuators. A dynamic model of the cybernetic actuator, taking into account its piezoelectric effect, is proposed and its detailed performance analyzed. Based on the result, a new technique to minimize the number of lead wires is proposed and verified experimentally. FMVC (Frequency Modulation Velocity Control) with two lead wires as an analog control method has been perfected.