一种用于单细胞捕获和阻抗测量的微流体装置

Min-Haw Wang, Min-Feng Kao, Haw-Juin Liu, Wai-Hong Kan, Y. Hsu, L. Jang
{"title":"一种用于单细胞捕获和阻抗测量的微流体装置","authors":"Min-Haw Wang, Min-Feng Kao, Haw-Juin Liu, Wai-Hong Kan, Y. Hsu, L. Jang","doi":"10.1109/NEMS.2007.352117","DOIUrl":null,"url":null,"abstract":"A microfluidic device for capture of single cells and impedance measurement is presented. The device consists of a PDMS channel with three micro pillars and a glass substrate with electrodes. The experiments demonstrated that the HeLa cell (human cervical epithelioid carcinoma) was successfully captured by the micro pillars and its impedance was measured by impedance spectroscopy. The range of operation voltage is from 0.1 V to 1.5 V and the scan frequency is from 1 kHz to 100 kHz. According to experimental results, the HeLa cell is capacitive and its electrical model can be simplified to the parallel connection with one resistor and one capacitor. This developed technique for cell impedance analysis possesses advantages of physical capture, low cost, and easy of fabrication and measurement.","PeriodicalId":364039,"journal":{"name":"2007 2nd IEEE International Conference on Nano/Micro Engineered and Molecular Systems","volume":"381 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"A Microfluidic Device for Capture of Single Cells and Impedance Measurement\",\"authors\":\"Min-Haw Wang, Min-Feng Kao, Haw-Juin Liu, Wai-Hong Kan, Y. Hsu, L. Jang\",\"doi\":\"10.1109/NEMS.2007.352117\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A microfluidic device for capture of single cells and impedance measurement is presented. The device consists of a PDMS channel with three micro pillars and a glass substrate with electrodes. The experiments demonstrated that the HeLa cell (human cervical epithelioid carcinoma) was successfully captured by the micro pillars and its impedance was measured by impedance spectroscopy. The range of operation voltage is from 0.1 V to 1.5 V and the scan frequency is from 1 kHz to 100 kHz. According to experimental results, the HeLa cell is capacitive and its electrical model can be simplified to the parallel connection with one resistor and one capacitor. This developed technique for cell impedance analysis possesses advantages of physical capture, low cost, and easy of fabrication and measurement.\",\"PeriodicalId\":364039,\"journal\":{\"name\":\"2007 2nd IEEE International Conference on Nano/Micro Engineered and Molecular Systems\",\"volume\":\"381 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-04-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 2nd IEEE International Conference on Nano/Micro Engineered and Molecular Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NEMS.2007.352117\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 2nd IEEE International Conference on Nano/Micro Engineered and Molecular Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEMS.2007.352117","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

介绍了一种用于单细胞捕获和阻抗测量的微流控装置。该装置由带有三个微柱的PDMS通道和带有电极的玻璃基板组成。实验表明,微柱成功捕获了人宫颈上皮样癌HeLa细胞,并通过阻抗谱测量了HeLa细胞的阻抗。工作电压范围为0.1 V ~ 1.5 V,扫描频率范围为1khz ~ 100khz。实验结果表明,HeLa电池具有电容性,其电学模型可简化为一个电阻和一个电容并联。该方法具有物理捕获、成本低、易于制作和测量等优点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Microfluidic Device for Capture of Single Cells and Impedance Measurement
A microfluidic device for capture of single cells and impedance measurement is presented. The device consists of a PDMS channel with three micro pillars and a glass substrate with electrodes. The experiments demonstrated that the HeLa cell (human cervical epithelioid carcinoma) was successfully captured by the micro pillars and its impedance was measured by impedance spectroscopy. The range of operation voltage is from 0.1 V to 1.5 V and the scan frequency is from 1 kHz to 100 kHz. According to experimental results, the HeLa cell is capacitive and its electrical model can be simplified to the parallel connection with one resistor and one capacitor. This developed technique for cell impedance analysis possesses advantages of physical capture, low cost, and easy of fabrication and measurement.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信