屏蔽同轴电缆大电流注入测试电路模型的实验验证

G. Antonini, A. Scogna, A. Orlandi, R. Rizzi
{"title":"屏蔽同轴电缆大电流注入测试电路模型的实验验证","authors":"G. Antonini, A. Scogna, A. Orlandi, R. Rizzi","doi":"10.1109/ISEMC.2004.1349997","DOIUrl":null,"url":null,"abstract":"In order to validate, by means of measurement, some existing equivalent circuit models for the bulk current injection (BCI) test, a procedure is proposed to develop a proper circuit model for the injection clamp and the obtained circuit is introduced into the global one representing the overall cable. A suitable experimental set-up has been built and used. The measured induced voltages at the terminations of shielded coaxial cables are compared with those computed by the equivalent circuit. Upper and lower bounds are quantified in order to assess the order of accuracy of the predicted results.","PeriodicalId":378094,"journal":{"name":"2004 International Symposium on Electromagnetic Compatibility (IEEE Cat. No.04CH37559)","volume":"83 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Experimental validation of circuit models for bulk current injection (BCI) test on shielded coaxial cables\",\"authors\":\"G. Antonini, A. Scogna, A. Orlandi, R. Rizzi\",\"doi\":\"10.1109/ISEMC.2004.1349997\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to validate, by means of measurement, some existing equivalent circuit models for the bulk current injection (BCI) test, a procedure is proposed to develop a proper circuit model for the injection clamp and the obtained circuit is introduced into the global one representing the overall cable. A suitable experimental set-up has been built and used. The measured induced voltages at the terminations of shielded coaxial cables are compared with those computed by the equivalent circuit. Upper and lower bounds are quantified in order to assess the order of accuracy of the predicted results.\",\"PeriodicalId\":378094,\"journal\":{\"name\":\"2004 International Symposium on Electromagnetic Compatibility (IEEE Cat. No.04CH37559)\",\"volume\":\"83 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2004 International Symposium on Electromagnetic Compatibility (IEEE Cat. No.04CH37559)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.2004.1349997\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2004 International Symposium on Electromagnetic Compatibility (IEEE Cat. No.04CH37559)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2004.1349997","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

为了通过测量验证现有的大电流注入(BCI)测试等效电路模型,提出了一种建立合适的注入钳电路模型的方法,并将得到的电路引入到代表整体电缆的全局电路中。建立并使用了合适的实验装置。将实测的屏蔽同轴电缆端子感应电压与等效电路计算的感应电压进行了比较。上界和下界是量化的,以评估预测结果的准确性的顺序。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Experimental validation of circuit models for bulk current injection (BCI) test on shielded coaxial cables
In order to validate, by means of measurement, some existing equivalent circuit models for the bulk current injection (BCI) test, a procedure is proposed to develop a proper circuit model for the injection clamp and the obtained circuit is introduced into the global one representing the overall cable. A suitable experimental set-up has been built and used. The measured induced voltages at the terminations of shielded coaxial cables are compared with those computed by the equivalent circuit. Upper and lower bounds are quantified in order to assess the order of accuracy of the predicted results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信