{"title":"存在气隙时的同轴探头介电测量","authors":"A. P. Popov, M. Rotaru","doi":"10.1109/EPTC.2004.1396658","DOIUrl":null,"url":null,"abstract":"Interpolation formulas for retrieval of the dielectric constant of the substrate from the measured probe impedance within a specified frequency range are introduced. The proposed formulas were tested for retrieval of dielectric constant from impedance measurements for the substrates with known properties. It was found that the accuracy of the proposed interpolation formulas is better than 5% within the frequency range of 0.5-20 GHz.","PeriodicalId":370907,"journal":{"name":"Proceedings of 6th Electronics Packaging Technology Conference (EPTC 2004) (IEEE Cat. No.04EX971)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Coaxial probe dielectric measurements in the presence of airgaps\",\"authors\":\"A. P. Popov, M. Rotaru\",\"doi\":\"10.1109/EPTC.2004.1396658\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Interpolation formulas for retrieval of the dielectric constant of the substrate from the measured probe impedance within a specified frequency range are introduced. The proposed formulas were tested for retrieval of dielectric constant from impedance measurements for the substrates with known properties. It was found that the accuracy of the proposed interpolation formulas is better than 5% within the frequency range of 0.5-20 GHz.\",\"PeriodicalId\":370907,\"journal\":{\"name\":\"Proceedings of 6th Electronics Packaging Technology Conference (EPTC 2004) (IEEE Cat. No.04EX971)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-12-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 6th Electronics Packaging Technology Conference (EPTC 2004) (IEEE Cat. No.04EX971)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EPTC.2004.1396658\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 6th Electronics Packaging Technology Conference (EPTC 2004) (IEEE Cat. No.04EX971)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPTC.2004.1396658","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Coaxial probe dielectric measurements in the presence of airgaps
Interpolation formulas for retrieval of the dielectric constant of the substrate from the measured probe impedance within a specified frequency range are introduced. The proposed formulas were tested for retrieval of dielectric constant from impedance measurements for the substrates with known properties. It was found that the accuracy of the proposed interpolation formulas is better than 5% within the frequency range of 0.5-20 GHz.