{"title":"标准设备机架中固有的机柜屏蔽不能提供高性能屏蔽","authors":"J. Knighten, R.D. McLay, P. M. Rostek, J. Fan","doi":"10.1109/ISEMC.2004.1349853","DOIUrl":null,"url":null,"abstract":"Information technology equipment is often housed in racks enclosed as cabinets that are either poorly designed as electromagnetic shields or have not been specifically designed to provide high-performance shielding. This study examines the shielding characteristics of a class of computer systems each housed in similar cabinet racks that were not designed to provide significant levels of shielding. At frequencies above a few hundred MHz, these cabinet racks can provide shielding sufficient to be important in compliance with regulatory EMC requirements on radiated emissions. At frequencies lower than a few hundred MHz, these cabinet racks do not reliably provide significant shielding. These conclusions are based on radiated emissions testing of equipment racks with and without doors and side panels.","PeriodicalId":378094,"journal":{"name":"2004 International Symposium on Electromagnetic Compatibility (IEEE Cat. No.04CH37559)","volume":"274 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Cabinet shielding inherent in standard equipment racks not designed to provide high-performance shielding\",\"authors\":\"J. Knighten, R.D. McLay, P. M. Rostek, J. Fan\",\"doi\":\"10.1109/ISEMC.2004.1349853\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Information technology equipment is often housed in racks enclosed as cabinets that are either poorly designed as electromagnetic shields or have not been specifically designed to provide high-performance shielding. This study examines the shielding characteristics of a class of computer systems each housed in similar cabinet racks that were not designed to provide significant levels of shielding. At frequencies above a few hundred MHz, these cabinet racks can provide shielding sufficient to be important in compliance with regulatory EMC requirements on radiated emissions. At frequencies lower than a few hundred MHz, these cabinet racks do not reliably provide significant shielding. These conclusions are based on radiated emissions testing of equipment racks with and without doors and side panels.\",\"PeriodicalId\":378094,\"journal\":{\"name\":\"2004 International Symposium on Electromagnetic Compatibility (IEEE Cat. No.04CH37559)\",\"volume\":\"274 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2004 International Symposium on Electromagnetic Compatibility (IEEE Cat. No.04CH37559)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.2004.1349853\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2004 International Symposium on Electromagnetic Compatibility (IEEE Cat. No.04CH37559)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2004.1349853","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Cabinet shielding inherent in standard equipment racks not designed to provide high-performance shielding
Information technology equipment is often housed in racks enclosed as cabinets that are either poorly designed as electromagnetic shields or have not been specifically designed to provide high-performance shielding. This study examines the shielding characteristics of a class of computer systems each housed in similar cabinet racks that were not designed to provide significant levels of shielding. At frequencies above a few hundred MHz, these cabinet racks can provide shielding sufficient to be important in compliance with regulatory EMC requirements on radiated emissions. At frequencies lower than a few hundred MHz, these cabinet racks do not reliably provide significant shielding. These conclusions are based on radiated emissions testing of equipment racks with and without doors and side panels.