Liam Montgomery, Jance McGale, Brent Lanting, Ryan Willing
{"title":"在使用虚拟关节运动模拟器进行松弛测试时,对 TKA 膝关节韧带建模技术进行生物力学分析。","authors":"Liam Montgomery, Jance McGale, Brent Lanting, Ryan Willing","doi":"10.1080/10255842.2023.2256925","DOIUrl":null,"url":null,"abstract":"<p><p>Total knee arthroplasty (TKA) is an end-stage treatment for knee osteoarthritis that relieves pain and loss of mobility, but patient satisfaction and revision rates require improvement. One cause for TKA revision is joint instability, which may be due to improper ligament balancing. A better understanding of the relationship between prosthesis design, alignment, and ligament engagement is necessary to improve component designs and surgical techniques to achieve better outcomes. We investigated the biomechanical effects of ligament model complexity and ligament wrapping during laxity tests using a virtual joint motion simulator. There was little difference in kinematics due to ligament complexity or ligament wrapping.</p>","PeriodicalId":50640,"journal":{"name":"Computer Methods in Biomechanics and Biomedical Engineering","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Biomechanical analysis of ligament modelling techniques in TKA knees during laxity tests using a virtual joint motion simulator.\",\"authors\":\"Liam Montgomery, Jance McGale, Brent Lanting, Ryan Willing\",\"doi\":\"10.1080/10255842.2023.2256925\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Total knee arthroplasty (TKA) is an end-stage treatment for knee osteoarthritis that relieves pain and loss of mobility, but patient satisfaction and revision rates require improvement. One cause for TKA revision is joint instability, which may be due to improper ligament balancing. A better understanding of the relationship between prosthesis design, alignment, and ligament engagement is necessary to improve component designs and surgical techniques to achieve better outcomes. We investigated the biomechanical effects of ligament model complexity and ligament wrapping during laxity tests using a virtual joint motion simulator. There was little difference in kinematics due to ligament complexity or ligament wrapping.</p>\",\"PeriodicalId\":50640,\"journal\":{\"name\":\"Computer Methods in Biomechanics and Biomedical Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computer Methods in Biomechanics and Biomedical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1080/10255842.2023.2256925\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/9/13 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Methods in Biomechanics and Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/10255842.2023.2256925","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/13 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
Biomechanical analysis of ligament modelling techniques in TKA knees during laxity tests using a virtual joint motion simulator.
Total knee arthroplasty (TKA) is an end-stage treatment for knee osteoarthritis that relieves pain and loss of mobility, but patient satisfaction and revision rates require improvement. One cause for TKA revision is joint instability, which may be due to improper ligament balancing. A better understanding of the relationship between prosthesis design, alignment, and ligament engagement is necessary to improve component designs and surgical techniques to achieve better outcomes. We investigated the biomechanical effects of ligament model complexity and ligament wrapping during laxity tests using a virtual joint motion simulator. There was little difference in kinematics due to ligament complexity or ligament wrapping.
期刊介绍:
The primary aims of Computer Methods in Biomechanics and Biomedical Engineering are to provide a means of communicating the advances being made in the areas of biomechanics and biomedical engineering and to stimulate interest in the continually emerging computer based technologies which are being applied in these multidisciplinary subjects. Computer Methods in Biomechanics and Biomedical Engineering will also provide a focus for the importance of integrating the disciplines of engineering with medical technology and clinical expertise. Such integration will have a major impact on health care in the future.