{"title":"Investigation of Thermosonic Wire Bonding Resistance of Gold Wire Onto Copper Pad","authors":"Y. Jeng, S. Chiu, P. Huang, Shiuh-Hwa Shyu","doi":"10.1109/TEPM.2009.2034467","DOIUrl":null,"url":null,"abstract":"This paper discusses the electric performance for thermosonic wire bonding of gold wire onto copper pads. Various methods normally used to improve bondability were investigated including the bare copper pads with argon shielding gas and the copper pads with cupric oxide film, cuprous oxide film, and silver film. The micro-contact theory was used to determine the effective contact area. The circuit contact resistance was measured for each sample and was presented in terms of ultrasound power and effective contact area. The results show that the increase in the effective contact area leads to a lower circuit contact resistance before reaching a minimum value, and further increase in the effective contact area would not have noticeable effect on the resistance.","PeriodicalId":55010,"journal":{"name":"IEEE Transactions on Electronics Packaging Manufacturing","volume":"11 1","pages":"65-70"},"PeriodicalIF":0.0000,"publicationDate":"2010-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Electronics Packaging Manufacturing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TEPM.2009.2034467","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

This paper discusses the electric performance for thermosonic wire bonding of gold wire onto copper pads. Various methods normally used to improve bondability were investigated including the bare copper pads with argon shielding gas and the copper pads with cupric oxide film, cuprous oxide film, and silver film. The micro-contact theory was used to determine the effective contact area. The circuit contact resistance was measured for each sample and was presented in terms of ultrasound power and effective contact area. The results show that the increase in the effective contact area leads to a lower circuit contact resistance before reaching a minimum value, and further increase in the effective contact area would not have noticeable effect on the resistance.
金丝与铜焊盘热声焊电阻的研究
本文讨论了金丝与铜衬垫热超声焊线的电性能。研究了常用的几种提高结合力的方法,包括氩气保护裸铜焊盘、氧化铜焊盘、氧化亚铜焊盘和镀银焊盘。利用微接触理论确定了有效接触面积。测量了每个样品的电路接触电阻,并以超声功率和有效接触面积表示。结果表明,增大有效接触面积会使电路接触电阻在达到最小值之前减小,进一步增大有效接触面积对电路接触电阻的影响不明显。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信