Automated Regularized Deconvolution for Eliminating Extra-Column Effects in Fast High-Efficiency Separations

IF 7.3 1区 化学 Q1 CHEMISTRY, ANALYTICAL
Troy T. Handlovic, M. Farooq Wahab, Souvik Roy, Ronald E. Brown and Daniel W. Armstrong*, 
{"title":"Automated Regularized Deconvolution for Eliminating Extra-Column Effects in Fast High-Efficiency Separations","authors":"Troy T. Handlovic,&nbsp;M. Farooq Wahab,&nbsp;Souvik Roy,&nbsp;Ronald E. Brown and Daniel W. Armstrong*,&nbsp;","doi":"10.1021/acs.analchem.3c01279","DOIUrl":null,"url":null,"abstract":"<p >With the introduction of ultrahigh efficiency columns and fast separations, the need to eliminate peak deformation contributed by the instrument must be effectively solved. Herein, we develop a robust framework to automate deconvolution and minimize its artifacts, such as negative dips, wild noise oscillations, and ringing, by combining regularized deconvolution and Perona–Malik (PM) anisotropic diffusion methods. A asymmetric generalized normal (AGN) function is proposed to model the instrumental response for the first time. With no-column data at various flow rates, the interior point optimization algorithm extracts the parameters describing instrumental distortion. The column-only chromatogram was reconstructed using the Tikhonov regularization technique with minimal instrumental distortion. For illustration, four different chromatography systems are used in fast chiral and achiral separations with 2.1 and 4.6 mm i.d. columns. Ordinary HPLC data can approach highly optimized UHPLC data. Similarly, in fast HPLC-circular dichroism (CD) detection, 8000 plates were gained for a fast chiral separation. Moment analysis of deconvolved peaks confirms correction of the center of mass, variance, skew, and kurtosis. This approach can be easily integrated and used with virtually any separation and detection system to provide enhanced analytical data.</p>","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":"95 29","pages":"11028–11036"},"PeriodicalIF":7.3000,"publicationDate":"2023-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acs.analchem.3c01279","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 3

Abstract

With the introduction of ultrahigh efficiency columns and fast separations, the need to eliminate peak deformation contributed by the instrument must be effectively solved. Herein, we develop a robust framework to automate deconvolution and minimize its artifacts, such as negative dips, wild noise oscillations, and ringing, by combining regularized deconvolution and Perona–Malik (PM) anisotropic diffusion methods. A asymmetric generalized normal (AGN) function is proposed to model the instrumental response for the first time. With no-column data at various flow rates, the interior point optimization algorithm extracts the parameters describing instrumental distortion. The column-only chromatogram was reconstructed using the Tikhonov regularization technique with minimal instrumental distortion. For illustration, four different chromatography systems are used in fast chiral and achiral separations with 2.1 and 4.6 mm i.d. columns. Ordinary HPLC data can approach highly optimized UHPLC data. Similarly, in fast HPLC-circular dichroism (CD) detection, 8000 plates were gained for a fast chiral separation. Moment analysis of deconvolved peaks confirms correction of the center of mass, variance, skew, and kurtosis. This approach can be easily integrated and used with virtually any separation and detection system to provide enhanced analytical data.

Abstract Image

用于消除快速高效分离中柱外效应的自动正则反卷积
随着超高效率色谱柱和快速分离的引入,必须有效解决消除仪器带来的峰值变形的需求。在此,我们开发了一个鲁棒框架,通过结合正则化反卷积和Perona-Malik (PM)各向异性扩散方法,自动反卷积并最小化其伪影,如负倾、野生噪声振荡和振铃。首次提出了一个非对称广义正态(AGN)函数来模拟仪器响应。对于不同流速下的无柱数据,内部点优化算法提取描述仪器畸变的参数。利用吉洪诺夫正则化技术,以最小的仪器畸变重建了纯柱色谱。举例说明,四种不同的色谱系统用于快速手性和非手性分离与2.1和4.6毫米id柱。普通HPLC数据可以接近高度优化的UHPLC数据。同样,在快速hplc -圆二色性(CD)检测中,获得8000个板进行快速手性分离。反卷积峰的力矩分析证实了质心、方差、偏态和峰度的校正。这种方法可以很容易地集成和使用几乎任何分离和检测系统,以提供增强的分析数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Chemistry
Analytical Chemistry 化学-分析化学
CiteScore
12.10
自引率
12.20%
发文量
1949
审稿时长
1.4 months
期刊介绍: Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书