Atomically dispersed Ni-N-C electrocatalysts, studied by Ni L-edge spectro-ptychography

IF 1.8 4区 物理与天体物理 Q2 SPECTROSCOPY
Chunyang Zhang , Jiatang Chen , Hao Yuan , Jian Wang , Tianxiao Sun , Drew Higgins , Adam P. Hitchcock
{"title":"Atomically dispersed Ni-N-C electrocatalysts, studied by Ni L-edge spectro-ptychography","authors":"Chunyang Zhang ,&nbsp;Jiatang Chen ,&nbsp;Hao Yuan ,&nbsp;Jian Wang ,&nbsp;Tianxiao Sun ,&nbsp;Drew Higgins ,&nbsp;Adam P. Hitchcock","doi":"10.1016/j.elspec.2023.147364","DOIUrl":null,"url":null,"abstract":"<div><p><span>Soft X-ray spectro-ptychography of nickel-nitrogen-carbon electrocatalysts containing atomically dispersed Ni-based active sites were measured at the Ni L</span><sub>3</sub> edge. Samples prepared with two different loadings of Ni precursors were investigated and compared to the results of an earlier study using scanning transmission X-ray microscopy (STXM) [Zhang et al., ACS Catalysis 12 (2022) 8746]. The ptychography data sets were measured using a defocused probe (1–3 µm). The spatial resolution was improved from ∼60 nm (STXM) to ∼20 nm (ptychography). Spectro-ptychography stacks were measured at 4 component-specific energies (4-E stack) and at many energies across the full Ni L<sub>3</sub> edge (34-E stack). Maps of three key chemical components (Ni metal, Ni<sub>3</sub>S<sub>2,</sub> and atomically dispersed N-coordinated Ni catalyst sites) were derived by fits of suitable reference spectra to absorption signals derived from the amplitude images from ptychographic reconstruction. The spectro-ptychography 4-E and 34-E stacks gave chemical mapping similar to each other and to the earlier STXM results. The phase signals obtained from the same data set and reconstruction were also found to be analyzable using reference phase spectra extracted from the phase stack, which generated chemical maps similar to those based on ptychography amplitude data. By using a defocused probe, the radiation dose and acquisition times for spectro-ptychography are comparable to conventional STXM, but significantly improved spatial resolution was achieved. This study highlights the added value of spectro-ptychography relative to STXM for studies of electrocatalysts.</p></div>","PeriodicalId":15726,"journal":{"name":"Journal of Electron Spectroscopy and Related Phenomena","volume":"266 ","pages":"Article 147364"},"PeriodicalIF":1.8000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electron Spectroscopy and Related Phenomena","FirstCategoryId":"101","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0368204823000816","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SPECTROSCOPY","Score":null,"Total":0}
引用次数: 0

Abstract

Soft X-ray spectro-ptychography of nickel-nitrogen-carbon electrocatalysts containing atomically dispersed Ni-based active sites were measured at the Ni L3 edge. Samples prepared with two different loadings of Ni precursors were investigated and compared to the results of an earlier study using scanning transmission X-ray microscopy (STXM) [Zhang et al., ACS Catalysis 12 (2022) 8746]. The ptychography data sets were measured using a defocused probe (1–3 µm). The spatial resolution was improved from ∼60 nm (STXM) to ∼20 nm (ptychography). Spectro-ptychography stacks were measured at 4 component-specific energies (4-E stack) and at many energies across the full Ni L3 edge (34-E stack). Maps of three key chemical components (Ni metal, Ni3S2, and atomically dispersed N-coordinated Ni catalyst sites) were derived by fits of suitable reference spectra to absorption signals derived from the amplitude images from ptychographic reconstruction. The spectro-ptychography 4-E and 34-E stacks gave chemical mapping similar to each other and to the earlier STXM results. The phase signals obtained from the same data set and reconstruction were also found to be analyzable using reference phase spectra extracted from the phase stack, which generated chemical maps similar to those based on ptychography amplitude data. By using a defocused probe, the radiation dose and acquisition times for spectro-ptychography are comparable to conventional STXM, but significantly improved spatial resolution was achieved. This study highlights the added value of spectro-ptychography relative to STXM for studies of electrocatalysts.

原子分散Ni-N-C电催化剂的镍L边光谱研究
在Ni- L3边缘测量了含有原子分散Ni基活性位点的镍-氮-碳电催化剂的软x射线光谱。研究了用两种不同负载的Ni前驱体制备的样品,并将其与早期使用扫描透射x射线显微镜(STXM)的研究结果进行了比较[Zhang等人,ACS Catalysis 12(2022) 8746]。使用散焦探针(1-3µm)测量型图数据集。空间分辨率从~ 60 nm (STXM)提高到~ 20 nm (ptychography)。在4个组件特定能量(4- e堆栈)和整个Ni L3边缘的许多能量(34-E堆栈)下测量了谱图堆叠。三种关键化学成分(Ni金属,Ni3S2和原子分散的n -配位Ni催化剂位点)的图谱通过合适的参考光谱与从平面重建的振幅图像中获得的吸收信号进行拟合得到。光谱图4-E和34-E堆栈给出的化学图谱彼此相似,也与早期的STXM结果相似。从相同的数据集和重建中获得的相位信号也发现可以使用从相位堆栈中提取的参考相位谱进行分析,其生成的化学图类似于基于平面振幅数据的化学图。通过使用散焦探针,光谱型图的辐射剂量和采集时间与传统STXM相当,但显著提高了空间分辨率。这项研究突出了相对于STXM的光谱型图在电催化剂研究中的附加价值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.30
自引率
5.30%
发文量
64
审稿时长
60 days
期刊介绍: The Journal of Electron Spectroscopy and Related Phenomena publishes experimental, theoretical and applied work in the field of electron spectroscopy and electronic structure, involving techniques which use high energy photons (>10 eV) or electrons as probes or detected particles in the investigation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信