Designing a circular coil of repetitive transcranial magnetic stimulation at frequencies of 0.5 and 1 Hz using CST studio suite software and comparison of results with theoretical calculations

IF 1 Q4 BIOTECHNOLOGY & APPLIED MICROBIOLOGY
H. Tavakoli, Arsalan Heidarpanah
{"title":"Designing a circular coil of repetitive transcranial magnetic stimulation at frequencies of 0.5 and 1 Hz using CST studio suite software and comparison of results with theoretical calculations","authors":"H. Tavakoli, Arsalan Heidarpanah","doi":"10.4103/bbrj.bbrj_174_22","DOIUrl":null,"url":null,"abstract":"Context: Since the 1990s, repetitive transcranial magnetic stimulation (rTMS) has been used as a noninvasive method to diagnose and manage the treatment of many neurological disorders. The circular coil is one of the most common coils in rTMS devices. This study presents the design documentation of a circular coil for use in the rTMS device and examines the consistency of the magnetic field intensity (H) and the magnetic flux density (B) obtained from the simulation of its use with the theoretical values. Aims: This study aimed to design a rTMS circular coil at frequencies of 0.5 and 1 Hz using CST Studio Suite software and compare the intensity of the B- and H-fields with theoretical calculations. Materials and Methods: After designing a circular coil, we measured B and H by simulation with CST Studio Suite software and compared the results with theoretical calculations. Results: The magnetic field intensity and the magnetic flux density obtained from the circular coil simulation we designed had an acceptable consistency with the theoretical values. Conclusions: The B- and H-field intensity whether on the body or in the air, or on the antenna, is fairishly consistent with theoretical calculations.","PeriodicalId":36500,"journal":{"name":"Biomedical and Biotechnology Research Journal","volume":"6 1","pages":"382 - 386"},"PeriodicalIF":1.0000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical and Biotechnology Research Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/bbrj.bbrj_174_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 1

Abstract

Context: Since the 1990s, repetitive transcranial magnetic stimulation (rTMS) has been used as a noninvasive method to diagnose and manage the treatment of many neurological disorders. The circular coil is one of the most common coils in rTMS devices. This study presents the design documentation of a circular coil for use in the rTMS device and examines the consistency of the magnetic field intensity (H) and the magnetic flux density (B) obtained from the simulation of its use with the theoretical values. Aims: This study aimed to design a rTMS circular coil at frequencies of 0.5 and 1 Hz using CST Studio Suite software and compare the intensity of the B- and H-fields with theoretical calculations. Materials and Methods: After designing a circular coil, we measured B and H by simulation with CST Studio Suite software and compared the results with theoretical calculations. Results: The magnetic field intensity and the magnetic flux density obtained from the circular coil simulation we designed had an acceptable consistency with the theoretical values. Conclusions: The B- and H-field intensity whether on the body or in the air, or on the antenna, is fairishly consistent with theoretical calculations.
使用CST studio套件软件设计频率为0.5和1 Hz的重复经颅磁刺激的圆形线圈,并将结果与理论计算进行比较
背景:自20世纪90年代以来,重复经颅磁刺激(rTMS)已被用作诊断和治疗许多神经系统疾病的非侵入性方法。圆形线圈是rTMS设备中最常见的线圈之一。本研究介绍了rTMS装置中使用的圆形线圈的设计文件,并检查了通过模拟其使用获得的磁场强度(H)和磁通密度(B)与理论值的一致性。目的:本研究旨在使用CST Studio Suite软件设计频率为0.5和1 Hz的rTMS圆形线圈,并将B场和H场的强度与理论计算进行比较。材料和方法:在设计了一个圆形线圈后,我们用CST Studio Suite软件模拟测量了B和H,并将结果与理论计算结果进行了比较。结果:我们设计的圆形线圈模拟得到的磁场强度和磁通密度与理论值具有可接受的一致性。结论:无论是在身体上、空气中还是在天线上,B场和H场的强度都与理论计算完全一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biomedical and Biotechnology Research Journal
Biomedical and Biotechnology Research Journal Biochemistry, Genetics and Molecular Biology-Biotechnology
CiteScore
2.20
自引率
42.90%
发文量
24
审稿时长
11 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信