{"title":"4th generation district heating (4GDH) in developing countries: Low-temperature networks, prosumers and demand-side measures","authors":"Stanislav Chicherin ,&nbsp;Andrey Zhuikov ,&nbsp;Lyazzat Junussova","doi":"10.1016/j.enbuild.2023.113298","DOIUrl":null,"url":null,"abstract":"<div><p>The aim is locating low-cost renovation measures to support the efficiency of district heating (DH). The topology analysis and GIS Zulu© are applied for hydraulic simulation and to verify the scenario viability. The scenarios are compared by life cycle cost, levelized cost of heat (LCoH), capital and operational costs, energy production and consumption, network length, heat losses, linear heat density, heat pump usage, peak load reduction, nominal power duration or the equivalent full load time. As demand-side measures (DSM), improved control, thermostats with an indoor temperature sensor and variable frequency drive (VFD) pumps reduce heat demand. Prosumer scenario imply installing a base-load heat pump. It means a consumer no longer receives heat from the DH system, because the households are now adapted to lower space heating (SH) supply temperature. Prosumer concept also allows placing a heat pump on the DH return line. The simplest configuration includes only the booster heat pump and domestic hot water (DHW) tank storages enough to cover morning or evening consumption peak. To limit piping cost, only supply and return pipes are considered for low-temperature DH, no additional (service) pipes or mixing valves are assumed. Converting single-family houses to prosumers decreases energy consumption, primary network flows and temperatures. LCoH ranges 19.7–35.4<!--> <!-->EUR/MWh, depends on the decommissioned pipe length and its proportional pipe investment cost. LCoH decreases as the share of consumers converted to prosumers increases. Discounted payback time is 10 years for DSM and 41 years for prosumer case. For a base-load heat pump, the payback time is much higher than the reference scenario. It implies the same share of heat losses (16% of heat supplied from the CHP plant) with generally worse environmental and energy saving effect due to higher greenhouse gas (GHG) emissions and higher consumption of primary energy. Energy production is expected to follow the pattern of the useful energy consumption to compensate heat losses. The effects are decreasing residential heat demand (-4%), additional capacity to connect new consumers (+6%) and decreasing the network length.</p></div>","PeriodicalId":11641,"journal":{"name":"Energy and Buildings","volume":"295 ","pages":"Article 113298"},"PeriodicalIF":6.6000,"publicationDate":"2023-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy and Buildings","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0378778823005285","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The aim is locating low-cost renovation measures to support the efficiency of district heating (DH). The topology analysis and GIS Zulu© are applied for hydraulic simulation and to verify the scenario viability. The scenarios are compared by life cycle cost, levelized cost of heat (LCoH), capital and operational costs, energy production and consumption, network length, heat losses, linear heat density, heat pump usage, peak load reduction, nominal power duration or the equivalent full load time. As demand-side measures (DSM), improved control, thermostats with an indoor temperature sensor and variable frequency drive (VFD) pumps reduce heat demand. Prosumer scenario imply installing a base-load heat pump. It means a consumer no longer receives heat from the DH system, because the households are now adapted to lower space heating (SH) supply temperature. Prosumer concept also allows placing a heat pump on the DH return line. The simplest configuration includes only the booster heat pump and domestic hot water (DHW) tank storages enough to cover morning or evening consumption peak. To limit piping cost, only supply and return pipes are considered for low-temperature DH, no additional (service) pipes or mixing valves are assumed. Converting single-family houses to prosumers decreases energy consumption, primary network flows and temperatures. LCoH ranges 19.7–35.4 EUR/MWh, depends on the decommissioned pipe length and its proportional pipe investment cost. LCoH decreases as the share of consumers converted to prosumers increases. Discounted payback time is 10 years for DSM and 41 years for prosumer case. For a base-load heat pump, the payback time is much higher than the reference scenario. It implies the same share of heat losses (16% of heat supplied from the CHP plant) with generally worse environmental and energy saving effect due to higher greenhouse gas (GHG) emissions and higher consumption of primary energy. Energy production is expected to follow the pattern of the useful energy consumption to compensate heat losses. The effects are decreasing residential heat demand (-4%), additional capacity to connect new consumers (+6%) and decreasing the network length.

发展中国家的第四代区域供热(4GDH):低温网络、生产者和需求方措施
目的是寻找低成本的改造措施,以支持区域供热(DH)的效率。应用拓扑分析和GIS Zulu©进行了液压仿真,验证了场景的可行性。通过生命周期成本、热平衡成本(LCoH)、资本和运营成本、能源生产和消耗、网络长度、热损失、线性热密度、热泵使用、峰值负荷减少、标称功率持续时间或等效满负荷时间对这些方案进行比较。作为需求侧措施(DSM),改进的控制,带有室内温度传感器的恒温器和变频驱动(VFD)泵减少了热量需求。Prosumer场景意味着安装一个基本负荷热泵。这意味着消费者不再从卫生系统接收热量,因为家庭现在已经适应了较低的空间供暖(SH)供应温度。Prosumer概念还允许在DH返回线上放置热泵。最简单的配置包括只有增压热泵和生活热水(DHW)罐存储足以覆盖早晨或晚上的消费高峰。为了限制管道成本,低温DH只考虑供回水管道,不考虑额外的(服务)管道或混合阀。将单户住宅转换为消费住宅可以减少能源消耗、初级网络流量和温度。LCoH范围为19.7-35.4欧元/兆瓦时,取决于退役管道长度及其相应的管道投资成本。LCoH随着消费者转化为生产消费者的比例的增加而下降。贴现后的投资回收期是DSM的10年和proconsumer的41年。对于基负荷热泵,投资回收期远高于参考方案。这意味着同样的热损失份额(热电联产厂提供的热量的16%),由于温室气体(GHG)排放较高和一次能源消耗较高,通常环境和节能效果较差。预计能源生产将遵循有用能源消耗的模式,以补偿热损失。其影响是减少住宅热需求(-4%),增加连接新用户的容量(+6%)和缩短网络长度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Energy and Buildings
Energy and Buildings 工程技术-工程:土木
CiteScore
12.70
自引率
11.90%
发文量
863
审稿时长
38 days
期刊介绍: An international journal devoted to investigations of energy use and efficiency in buildings Energy and Buildings is an international journal publishing articles with explicit links to energy use in buildings. The aim is to present new research results, and new proven practice aimed at reducing the energy needs of a building and improving indoor environment quality.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信