{"title":"Fe<sub>0.79</sub>Si<sub>0.07</sub>B<sub>0.14</sub> metallic glass gaskets for high-pressure research beyond 1 Mbar.","authors":"Weiwei Dong, Konstantin Glazyrin, Saiana Khandarkhaeva, Timofey Fedotenko, Jozef Bednarčík, Eran Greenberg, Leonid Dubrovinsky, Natalia Dubrovinskaia, Hanns Peter Liermann","doi":"10.1107/S1600577522007573","DOIUrl":null,"url":null,"abstract":"<p><p>A gasket is an important constituent of a diamond anvil cell (DAC) assembly, responsible for the sample chamber stability at extreme conditions for X-ray diffraction studies. In this work, we studied the performance of gaskets made of metallic glass Fe<sub>0.79</sub>Si<sub>0.07</sub>B<sub>0.14</sub> in a number of high-pressure X-ray diffraction (XRD) experiments in DACs equipped with conventional and toroidal-shape diamond anvils. The experiments were conducted in either axial or radial geometry with X-ray beams of micrometre to sub-micrometre size. We report that Fe<sub>0.79</sub>Si<sub>0.07</sub>B<sub>0.14</sub> metallic glass gaskets offer a stable sample environment under compression exceeding 1 Mbar in all XRD experiments described here, even in those involving small-molecule gases (e.g. Ne, H<sub>2</sub>) used as pressure-transmitting media or in those with laser heating in a DAC. Our results emphasize the material's importance for a great number of delicate experiments conducted under extreme conditions. They indicate that the application of Fe<sub>0.79</sub>Si<sub>0.07</sub>B<sub>0.14</sub> metallic glass gaskets in XRD experiments for both axial and radial geometries substantially improves various aspects of megabar experiments and, in particular, the signal-to-noise ratio in comparison to that with conventional gaskets made of Re, W, steel or other crystalline metals.</p>","PeriodicalId":17114,"journal":{"name":"Journal of Synchrotron Radiation","volume":"29 Pt 5","pages":"1167-1179"},"PeriodicalIF":2.4000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9455203/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Synchrotron Radiation","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1107/S1600577522007573","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/8/19 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

A gasket is an important constituent of a diamond anvil cell (DAC) assembly, responsible for the sample chamber stability at extreme conditions for X-ray diffraction studies. In this work, we studied the performance of gaskets made of metallic glass Fe0.79Si0.07B0.14 in a number of high-pressure X-ray diffraction (XRD) experiments in DACs equipped with conventional and toroidal-shape diamond anvils. The experiments were conducted in either axial or radial geometry with X-ray beams of micrometre to sub-micrometre size. We report that Fe0.79Si0.07B0.14 metallic glass gaskets offer a stable sample environment under compression exceeding 1 Mbar in all XRD experiments described here, even in those involving small-molecule gases (e.g. Ne, H2) used as pressure-transmitting media or in those with laser heating in a DAC. Our results emphasize the material's importance for a great number of delicate experiments conducted under extreme conditions. They indicate that the application of Fe0.79Si0.07B0.14 metallic glass gaskets in XRD experiments for both axial and radial geometries substantially improves various aspects of megabar experiments and, in particular, the signal-to-noise ratio in comparison to that with conventional gaskets made of Re, W, steel or other crystalline metals.

Abstract Image

Abstract Image

Abstract Image

用于 1 Mbar 以上高压研究的 Fe0.79Si0.07B0.14 金属玻璃垫圈。
垫片是金刚石砧室(DAC)组件的重要组成部分,负责 X 射线衍射研究中样品室在极端条件下的稳定性。在这项工作中,我们研究了金属玻璃 Fe0.79Si0.07B0.14 制成的垫片在配备传统和环形金刚石砧的 DAC 中进行的一系列高压 X 射线衍射(XRD)实验中的性能。实验采用轴向或径向几何形状,X 射线束的尺寸从微米到亚微米不等。我们报告说,在此处描述的所有 XRD 实验中,Fe0.79Si0.07B0.14 金属玻璃垫圈在超过 1 Mbar 的压缩条件下提供了稳定的样品环境,即使在涉及用作压力传输介质的小分子气体(如 Ne、H2)或在 DAC 中使用激光加热的实验中也是如此。我们的研究结果强调了这种材料对于在极端条件下进行的大量精细实验的重要性。结果表明,在轴向和径向几何形状的 XRD 实验中应用 Fe0.79Si0.07B0.14 金属玻璃垫片,与使用由 Re、W、钢或其他结晶金属制成的传统垫片相比,大大提高了兆巴实验的各个方面,特别是信噪比。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.10
自引率
12.00%
发文量
289
审稿时长
4-8 weeks
期刊介绍: Synchrotron radiation research is rapidly expanding with many new sources of radiation being created globally. Synchrotron radiation plays a leading role in pure science and in emerging technologies. The Journal of Synchrotron Radiation provides comprehensive coverage of the entire field of synchrotron radiation and free-electron laser research including instrumentation, theory, computing and scientific applications in areas such as biology, nanoscience and materials science. Rapid publication ensures an up-to-date information resource for scientists and engineers in the field.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信