{"title":"Selective Correction of Condition-Sensitive Parameters for Cross-Condition Torque Prediction in an EMG-Driven Elbow Musculoskeletal Model.","authors":"Jianshe Gao, Yu Wang, Xiaobo Rao, Xingzhao Guo, Qiang Liu, Jie Wang","doi":"10.1088/1873-4030/aebecf","DOIUrl":null,"url":null,"abstract":"<p><p>Electromyography-driven musculoskeletal models estimate muscle forces and joint torque. A shared parameter set can leave errors that vary with movement speed and load. This study examined selective condition correction in an EMG-driven elbow model. The model retained a common parameter set and added speed- and load-dependent terms only to selected parameters. Ten healthy participants performed constrained isokinetic elbow flexion-extension. Subject-specific MuJoCo models were constructed from OpenSim arm26. Speed-Load had the lowest mean validation RMSE among three calibration combinations (1.37 N·m) and was used for common calibration. Length-range constraints were included during fitting. Full reduced mean RMSE by 10.0-18.6% across held-out repetitions, interpolation and extrapolation conditions. The largest reduction occurred in extrapolation: RMSE decreased from 2.08 to 1.70 N·m, while mean R² increased from 0.71 to 0.81. The ablation models had intermediate mean errors. The full two-stage procedure improved within-subject torque prediction across the tested speed and target-torque conditions with a limited number of additional coefficients.</p>","PeriodicalId":49836,"journal":{"name":"Medical Engineering & Physics","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2026-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Engineering & Physics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1873-4030/aebecf","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Electromyography-driven musculoskeletal models estimate muscle forces and joint torque. A shared parameter set can leave errors that vary with movement speed and load. This study examined selective condition correction in an EMG-driven elbow model. The model retained a common parameter set and added speed- and load-dependent terms only to selected parameters. Ten healthy participants performed constrained isokinetic elbow flexion-extension. Subject-specific MuJoCo models were constructed from OpenSim arm26. Speed-Load had the lowest mean validation RMSE among three calibration combinations (1.37 N·m) and was used for common calibration. Length-range constraints were included during fitting. Full reduced mean RMSE by 10.0-18.6% across held-out repetitions, interpolation and extrapolation conditions. The largest reduction occurred in extrapolation: RMSE decreased from 2.08 to 1.70 N·m, while mean R² increased from 0.71 to 0.81. The ablation models had intermediate mean errors. The full two-stage procedure improved within-subject torque prediction across the tested speed and target-torque conditions with a limited number of additional coefficients.

在肌电驱动的肘关节肌肉骨骼模型中,条件敏感参数的选择性校正用于交叉条件扭矩预测。
肌电图驱动的肌肉骨骼模型估计肌肉力量和关节扭矩。共享参数集可能会留下随移动速度和负载变化的错误。本研究检查了肌电驱动肘关节模型的选择性条件校正。该模型保留了一个公共参数集,并仅在选定的参数中添加了与速度和负载相关的项。10名健康参与者进行了受限的等速肘关节屈伸。特定于受试者的MuJoCo模型由OpenSim arm26构建。3种校准组合中,Speed-Load的平均验证均方根误差(RMSE)最低(1.37 N·m),用于常用校准。拟合过程中包含了长范围约束。在重复、插值和外推条件下,完全降低平均RMSE 10.0-18.6%。外推法降低幅度最大:RMSE从2.08下降到1.70 N·m,平均R²从0.71上升到0.81。消融模型具有中等平均误差。整个过程分为两个阶段,通过有限数量的附加系数,改进了测试速度和目标扭矩条件下的受试者内扭矩预测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical Engineering & Physics
Medical Engineering & Physics 工程技术-工程:生物医学
CiteScore
4.30
自引率
4.50%
发文量
172
审稿时长
3.0 months
期刊介绍: Medical Engineering & Physics provides a forum for the publication of the latest developments in biomedical engineering, and reflects the essential multidisciplinary nature of the subject. The journal publishes in-depth critical reviews, scientific papers and technical notes. Our focus encompasses the application of the basic principles of physics and engineering to the development of medical devices and technology, with the ultimate aim of producing improvements in the quality of health care.Topics covered include biomechanics, biomaterials, mechanobiology, rehabilitation engineering, biomedical signal processing and medical device development. Medical Engineering & Physics aims to keep both engineers and clinicians abreast of the latest applications of technology to health care.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书