Dexin Hou, Tiancheng Xie, Yiming Lv, Ji Mi, Jiong Ding, Dongfang Hu
{"title":"A thermopile array and stereo vision fusion system for small-tube temperature sensing.","authors":"Dexin Hou, Tiancheng Xie, Yiming Lv, Ji Mi, Jiong Ding, Dongfang Hu","doi":"10.1063/5.0346570","DOIUrl":null,"url":null,"abstract":"<p><p>This paper presents a non-contact temperature measurement scheme for small-diameter tubes by fusing a low-resolution thermopile array (TPA) with visible-light stereo vision. Stereo vision locates the tube in three dimensions. Then, this geometry is projected onto the TPA imaging plane to constrain the radiation integration model. A spherical calibration target with an internal heat source is proposed, achieving a sub-pixel accuracy of 1/28 of a pixel via symmetry-based active aiming. Experiments on 3 and 2 mm heated tubes show that the proposed method reduces the mean absolute percentage error from 28% and 36% to 3.4% and 4.3%, respectively. Furthermore, the system resolves emissivity-induced circumferential temperature non-uniformities with a rotational resolution of 5°. These results demonstrate that multi-sensor fusion effectively overcomes the size-of-source effect in low-cost infrared sensing.</p>","PeriodicalId":21111,"journal":{"name":"Review of Scientific Instruments","volume":"97 10","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Review of Scientific Instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0346570","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0
Abstract
This paper presents a non-contact temperature measurement scheme for small-diameter tubes by fusing a low-resolution thermopile array (TPA) with visible-light stereo vision. Stereo vision locates the tube in three dimensions. Then, this geometry is projected onto the TPA imaging plane to constrain the radiation integration model. A spherical calibration target with an internal heat source is proposed, achieving a sub-pixel accuracy of 1/28 of a pixel via symmetry-based active aiming. Experiments on 3 and 2 mm heated tubes show that the proposed method reduces the mean absolute percentage error from 28% and 36% to 3.4% and 4.3%, respectively. Furthermore, the system resolves emissivity-induced circumferential temperature non-uniformities with a rotational resolution of 5°. These results demonstrate that multi-sensor fusion effectively overcomes the size-of-source effect in low-cost infrared sensing.
期刊介绍:
Review of Scientific Instruments, is committed to the publication of advances in scientific instruments, apparatuses, and techniques. RSI seeks to meet the needs of engineers and scientists in physics, chemistry, and the life sciences.