Electrophoresis-Correlative diaPASEF Improves Low-Input and Single-Cell CE−ESI−MS Proteomics by Targeting Peptide-Enriched Acquisition Space

IF 7.3 1区 化学 Q1 CHEMISTRY, ANALYTICAL
Fei Zhou,Bowen Shen,Nicolas Drouin,Peter Nemes
{"title":"Electrophoresis-Correlative diaPASEF Improves Low-Input and Single-Cell CE−ESI−MS Proteomics by Targeting Peptide-Enriched Acquisition Space","authors":"Fei Zhou,Bowen Shen,Nicolas Drouin,Peter Nemes","doi":"10.1021/acs.analchem.6c03247","DOIUrl":null,"url":null,"abstract":"In low-input proteomics, proteome coverage is often limited not only by sample amount but also by inefficient tandem mass spectrometry (MS) sampling of peptide-rich acquisition space. During capillary electrophoresis (CE)−electrospray ionization (ESI)−MS analysis, electrophoretically separated peptides occupy reproducible, correlated regions of migration time, precursor mass-to-charge ratio (m/z), and ion mobility (IM), creating an opportunity to direct data-independent acquisition (DIA) toward peptide-enriched regions. Here, we introduce electrophoresis-correlative diaPASEF (Eco-diaPASEF), a CE-informed implementation of diaPASEF that uses migration time-correlated m/z and IM information to define complementary acquisition segments while maintaining the reference cycle time. By restricting IM scan range, precursor m/z space, and DIA isolation width, Eco-diaPASEF focuses tandem MS acquisition on peptide-enriched regions. In low-input HeLa digest samples, Eco-diaPASEF increased protein-group (PG) identifications by up to ∼65% relative to conventional diaPASEF, cumulatively identifying up to 1163 PGs across 4 technical replicates from 200 pg of digest measured per run on a timsTOF Pro mass spectrometer. Applied to single animal-cap cells from stage-9 Xenopus laevis embryos, Eco-diaPASEF cumulatively quantified 1108 PGs across 3 cells using ∼200 pg of injected digest per cell. The method provided ∼2.6−2.7-fold greater proteome coverage across replicate criteria while maintaining comparable biological-replicate precision. These results establish Eco-diaPASEF as a CE-guided acquisition strategy for improving proteome coverage in low-input and single-cell CE−ESI−MS proteomics on IM-enabled mass spectrometers.","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":"56 1","pages":""},"PeriodicalIF":7.3000,"publicationDate":"2026-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acs.analchem.6c03247","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

In low-input proteomics, proteome coverage is often limited not only by sample amount but also by inefficient tandem mass spectrometry (MS) sampling of peptide-rich acquisition space. During capillary electrophoresis (CE)−electrospray ionization (ESI)−MS analysis, electrophoretically separated peptides occupy reproducible, correlated regions of migration time, precursor mass-to-charge ratio (m/z), and ion mobility (IM), creating an opportunity to direct data-independent acquisition (DIA) toward peptide-enriched regions. Here, we introduce electrophoresis-correlative diaPASEF (Eco-diaPASEF), a CE-informed implementation of diaPASEF that uses migration time-correlated m/z and IM information to define complementary acquisition segments while maintaining the reference cycle time. By restricting IM scan range, precursor m/z space, and DIA isolation width, Eco-diaPASEF focuses tandem MS acquisition on peptide-enriched regions. In low-input HeLa digest samples, Eco-diaPASEF increased protein-group (PG) identifications by up to ∼65% relative to conventional diaPASEF, cumulatively identifying up to 1163 PGs across 4 technical replicates from 200 pg of digest measured per run on a timsTOF Pro mass spectrometer. Applied to single animal-cap cells from stage-9 Xenopus laevis embryos, Eco-diaPASEF cumulatively quantified 1108 PGs across 3 cells using ∼200 pg of injected digest per cell. The method provided ∼2.6−2.7-fold greater proteome coverage across replicate criteria while maintaining comparable biological-replicate precision. These results establish Eco-diaPASEF as a CE-guided acquisition strategy for improving proteome coverage in low-input and single-cell CE−ESI−MS proteomics on IM-enabled mass spectrometers.
电泳-相关diaPASEF提高低输入和单细胞CE - ESI - MS蛋白质组学靶向肽富集获取空间
在低输入的蛋白质组学中,蛋白质组的覆盖范围不仅受到样本量的限制,而且还受到串联质谱(MS)对富含肽的获取空间的低效采样的限制。在毛细管电泳(CE) -电喷雾电离(ESI) -质谱分析过程中,电泳分离的肽占据了迁移时间、前体质荷比(m/z)和离子迁移率(IM)的可重复的相关区域,从而为将数据独立采集(DIA)直接用于肽富集区域创造了机会。在这里,我们介绍了电泳相关的diaPASEF (Eco-diaPASEF),这是一种ce通知的diaPASEF实现,它使用迁移时间相关的m/z和IM信息来定义互补的采集段,同时保持参考周期时间。通过限制IM扫描范围、前体m/z空间和DIA分离宽度,Eco-diaPASEF将串联质谱采集集中在肽富集区域。在低输入的HeLa消化样品中,相对于传统的diaPASEF, Eco-diaPASEF增加了蛋白质组(PG)的鉴定高达~ 65%,在timsTOF Pro质谱仪上每次运行测量200 PG消化样品,在4个技术重复中累计鉴定多达1163个PG。应用于9期非洲爪蟾胚胎的单个动物帽细胞,Eco-diaPASEF在3个细胞中累积量化1108个pg,每个细胞注射200 pg消化液。该方法在重复标准中提供了约2.6 - 2.7倍的蛋白质组覆盖率,同时保持了相当的生物复制精度。这些结果建立了Eco-diaPASEF作为一种CE指导的获取策略,用于提高低输入和单细胞CE- ESI - MS蛋白质组学在im启用质谱仪上的蛋白质组学覆盖率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Chemistry
Analytical Chemistry 化学-分析化学
CiteScore
12.10
自引率
12.20%
发文量
1949
审稿时长
1.4 months
期刊介绍: Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书