Ultrasensitive Quantification of Poloxamer 188 in Adeno-Associated Virus Products by All-Ion Fragmentation MS/MS

IF 7.3 1区 化学 Q1 CHEMISTRY, ANALYTICAL
Sisi Zhang,Jing Wang,Hui Xiao,Ning Li
{"title":"Ultrasensitive Quantification of Poloxamer 188 in Adeno-Associated Virus Products by All-Ion Fragmentation MS/MS","authors":"Sisi Zhang,Jing Wang,Hui Xiao,Ning Li","doi":"10.1021/acs.analchem.6c03755","DOIUrl":null,"url":null,"abstract":"Abstract Poloxamer 188 (P188; Pluronic F68) is a nonionic surfactant frequently used in biotherapeutics, particularly in adeno-associated virus (AAV) formulations, in which it is present at trace concentrations (0.001%−0.005%). However, its accurate quantification is difficult, because of its low abundance, frequently limited sample volumes, and the ionization variability of its PEO−PPO−PEO triblock. Here, we developed an all-ion fragmentation (AIF) workflow with 44 Da and 58 Da neutral-loss-triggered data dependent (dd)-MS2 that fragments all precursors and performs quantification via the polyethylene glycol (PEG) diagnostic ion (m/z 133.1), thereby decreasing spectral complexity and adduct variability. In contrast to the most sensitive reported method, LC−MRM, using a 20 μL injection volume, which achieved a dynamic range of 250−10,000 ng/mL (0.000025%−0.001%), our method achieved a 0.00002% LLOQ with 1 μL injections, thus providing an ∼20-fold sensitivity gain that enables replicate analysis and a dynamic range 2 orders of magnitude wider (0.00002%−0.1%). Our assay is vendor-, formulation-, and LC-buffer-agnostic, and achieves ±10% accuracy and ∼10% CVs across AAV-relevant levels. Significant P188 losses attributable to container adsorption were observed; incorporation of 50% acetonitrile restored recovery and is recommended for sample preparation.","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":"39 1","pages":""},"PeriodicalIF":7.3000,"publicationDate":"2026-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acs.analchem.6c03755","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Poloxamer 188 (P188; Pluronic F68) is a nonionic surfactant frequently used in biotherapeutics, particularly in adeno-associated virus (AAV) formulations, in which it is present at trace concentrations (0.001%−0.005%). However, its accurate quantification is difficult, because of its low abundance, frequently limited sample volumes, and the ionization variability of its PEO−PPO−PEO triblock. Here, we developed an all-ion fragmentation (AIF) workflow with 44 Da and 58 Da neutral-loss-triggered data dependent (dd)-MS2 that fragments all precursors and performs quantification via the polyethylene glycol (PEG) diagnostic ion (m/z 133.1), thereby decreasing spectral complexity and adduct variability. In contrast to the most sensitive reported method, LC−MRM, using a 20 μL injection volume, which achieved a dynamic range of 250−10,000 ng/mL (0.000025%−0.001%), our method achieved a 0.00002% LLOQ with 1 μL injections, thus providing an ∼20-fold sensitivity gain that enables replicate analysis and a dynamic range 2 orders of magnitude wider (0.00002%−0.1%). Our assay is vendor-, formulation-, and LC-buffer-agnostic, and achieves ±10% accuracy and ∼10% CVs across AAV-relevant levels. Significant P188 losses attributable to container adsorption were observed; incorporation of 50% acetonitrile restored recovery and is recommended for sample preparation.
全离子碎片质谱/质谱法测定腺相关病毒产物中poloxam188的超灵敏含量
poloxam188 (P188; Pluronic F68)是一种非离子表面活性剂,经常用于生物治疗药物,特别是在腺相关病毒(AAV)制剂中,其浓度为微量(0.001% - 0.005%)。然而,由于其丰度低、样品体积有限以及PEO−PPO−PEO三嵌段的电离变异性,其精确定量是困难的。在这里,我们开发了一种全离子碎片化(AIF)工作流程,采用44 Da和58 Da中性损失触发的数据依赖(dd)-MS2,将所有前体碎片化,并通过聚乙二醇(PEG)诊断离子(m/z 133.1)进行定量,从而降低了光谱复杂性和加合物的可变性。与目前报道的最灵敏的LC - MRM方法相比,使用20 μL进样量的LC - MRM方法的动态范围为250 - 10,000 ng/mL(0.000025% - 0.001%),该方法在1 μL进样量下的LLOQ为0.00002%,从而提供了~ 20倍的灵敏度增益,可以重复分析,动态范围宽2个数量级(0.00002% - 0.1%)。我们的检测与供应商、制剂和lc缓冲液无关,在aav相关水平上达到±10%的准确度和~ 10%的cv。由于容器吸附,P188损失显著;加入50%乙腈可恢复回收率,建议用于样品制备。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Chemistry
Analytical Chemistry 化学-分析化学
CiteScore
12.10
自引率
12.20%
发文量
1949
审稿时长
1.4 months
期刊介绍: Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书