In Situ Time-Weighted Average Monitoring of 11 Antiviral Drugs in Natural Waters Using Diffusive Gradients in Thin-Films with Graphitized Carbon Black and Mixed-Mode Resin Binding Gels

IF 7.3 1区 化学 Q1 CHEMISTRY, ANALYTICAL
Zhou Fang,Kefei Huang,Hao Zhang,Kevin C. Jones,Haitao Sun,Li Zhang,Lei Zhang,Jun Luo
{"title":"In Situ Time-Weighted Average Monitoring of 11 Antiviral Drugs in Natural Waters Using Diffusive Gradients in Thin-Films with Graphitized Carbon Black and Mixed-Mode Resin Binding Gels","authors":"Zhou Fang,Kefei Huang,Hao Zhang,Kevin C. Jones,Haitao Sun,Li Zhang,Lei Zhang,Jun Luo","doi":"10.1021/acs.analchem.6c03524","DOIUrl":null,"url":null,"abstract":"Abstract The widespread occurrence of antiviral drugs in aquatic systems has raised concerns on their potential ecological risks, necessitating reliable monitoring techniques. This study introduces the first application of the diffusive gradients in thin-films (DGT) technique for the in situ measurement of 11 commonly used antiviral drugs from six therapeutic categories. Two complementary DGT configurations were developed, employing graphitized carbon black (ENVI-CARB) and a mixed-mode resin (MCX + HLB at a 6:4 mass ratio) embedded in agarose as the binding phases. Diffusion coefficients of all target compounds in the diffusive gel were determined for the first time using a diffusion cell, and stable elution efficiencies were obtained with acetonitrile/formic acid for ENVI-CARB and acetonitrile/ammonia for MCX + HLB. Both DGT devices performed robustly across wide environmental gradients: pH 3.16−9.74, ionic strength 0.1−500 mmol L−1 and dissolved organic matter up to 20 mg L−1. The total binding capacities exceeded 230 μg per disc, supporting deployments over several months in natural waters. Laboratory evaluations of diffusive layer thickness (0.515−2.015 mm), deployment time (10−168 h), storage stability (≥148 days) and competitive adsorption confirmed the reliability of the method. Field deployments at five river sites in Nanjing, China, during a 14 day period detected ribavirin (9−29 ng L−1) and lamivudine (12−29 ng L−1) as the predominant antivirals. The DGT-derived time-weighted average concentrations closely matched those from repeated grab sampling while effectively capturing episodic pollution events that individual grab samples missed. The developed DGT samplers thus provide a robust, cost-effective and sensitive tool for source tracking and long-term monitoring of antiviral drugs, overcoming the inherent limitations of conventional grab sampling in dynamic aquatic environments.","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":"292 1","pages":""},"PeriodicalIF":7.3000,"publicationDate":"2026-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acs.analchem.6c03524","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract The widespread occurrence of antiviral drugs in aquatic systems has raised concerns on their potential ecological risks, necessitating reliable monitoring techniques. This study introduces the first application of the diffusive gradients in thin-films (DGT) technique for the in situ measurement of 11 commonly used antiviral drugs from six therapeutic categories. Two complementary DGT configurations were developed, employing graphitized carbon black (ENVI-CARB) and a mixed-mode resin (MCX + HLB at a 6:4 mass ratio) embedded in agarose as the binding phases. Diffusion coefficients of all target compounds in the diffusive gel were determined for the first time using a diffusion cell, and stable elution efficiencies were obtained with acetonitrile/formic acid for ENVI-CARB and acetonitrile/ammonia for MCX + HLB. Both DGT devices performed robustly across wide environmental gradients: pH 3.16−9.74, ionic strength 0.1−500 mmol L−1 and dissolved organic matter up to 20 mg L−1. The total binding capacities exceeded 230 μg per disc, supporting deployments over several months in natural waters. Laboratory evaluations of diffusive layer thickness (0.515−2.015 mm), deployment time (10−168 h), storage stability (≥148 days) and competitive adsorption confirmed the reliability of the method. Field deployments at five river sites in Nanjing, China, during a 14 day period detected ribavirin (9−29 ng L−1) and lamivudine (12−29 ng L−1) as the predominant antivirals. The DGT-derived time-weighted average concentrations closely matched those from repeated grab sampling while effectively capturing episodic pollution events that individual grab samples missed. The developed DGT samplers thus provide a robust, cost-effective and sensitive tool for source tracking and long-term monitoring of antiviral drugs, overcoming the inherent limitations of conventional grab sampling in dynamic aquatic environments.
利用石墨化炭黑薄膜和混合模式树脂结合凝胶的扩散梯度对天然水体中11种抗病毒药物的原位时间加权平均监测
水生系统中抗病毒药物的广泛存在引起了人们对其潜在生态风险的关注,需要可靠的监测技术。本研究首次将薄膜扩散梯度(DGT)技术应用于6个治疗类别的11种常用抗病毒药物的原位测量。开发了两种互补的DGT结构,采用石墨化炭黑(ENVI-CARB)和混合模式树脂(MCX + HLB,质量比为6:4)嵌入琼脂糖作为结合相。首次使用扩散池测定了所有目标化合物在扩散凝胶中的扩散系数,并获得了稳定的乙腈/甲酸和乙腈/氨对ENVI-CARB和MCX + HLB的洗脱效率。这两种DGT器件在广泛的环境梯度中表现良好:pH为3.16 ~ 9.74,离子强度为0.1 ~ 500 mmol L−1,溶解有机物高达20 mg L−1。总绑定能力超过每盘230 μg,支持在自然水域部署数月。实验室对扩散层厚度(0.515 ~ 2.015 mm)、展开时间(10 ~ 168 h)、储存稳定性(≥148天)和竞争吸附的评价证实了该方法的可靠性。在中国南京的5个河流站点进行了为期14天的现场部署,检测到利巴韦林(9 ~ 29 ng L−1)和拉米夫定(12 ~ 29 ng L−1)是主要的抗病毒药物。dgt导出的时间加权平均浓度与重复抓取采样的浓度密切匹配,同时有效地捕获了单个抓取样本错过的偶发性污染事件。因此,开发的DGT采样器为抗病毒药物的来源跟踪和长期监测提供了一种强大、经济、敏感的工具,克服了动态水生环境中传统抓取采样的固有局限性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Chemistry
Analytical Chemistry 化学-分析化学
CiteScore
12.10
自引率
12.20%
发文量
1949
审稿时长
1.4 months
期刊介绍: Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书