Chen Wang,Yifei Zhang,Zhuoyin Liu,Qiang Zeng,Hui Yu,Xinping Guan,Yuting Yang
{"title":"Lock-in Biosensing beyond the Analog Ensemble Detection Limits","authors":"Chen Wang,Yifei Zhang,Zhuoyin Liu,Qiang Zeng,Hui Yu,Xinping Guan,Yuting Yang","doi":"10.1021/acs.analchem.6c04649","DOIUrl":null,"url":null,"abstract":"Abstract Clinical assessment of biomarkers via “analog” ensemble detection of molecular signals is fundamentally limited by the background noise from a detector and nonspecific binding. Although digital assays have emerged as a solution, their clinical translation remains challenging due to their reliance on sophisticated single-molecule sensing technologies. Here, we demonstrate that these analog limitations can be overcome using lock-in detection of ensemble signals. By modulating endpoint molecular binding events into periodic optical fluctuations, our approach amplifies weak molecular signals above the background noise floor. Experimental validation demonstrates a three-fold increase in the limit of sensitivity for single-stranded DNA and a one-order-of-magnitude increase for interleukin-6 (IL-6), achieving a limit of detection at the femtomolar level. Compatible with existing assay platforms, this ensemble lock-in biosensing strategy offers a simple yet effective route for the clinical detection of low-abundance biomarkers.","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":"51 1","pages":""},"PeriodicalIF":7.3000,"publicationDate":"2026-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acs.analchem.6c04649","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Abstract Clinical assessment of biomarkers via “analog” ensemble detection of molecular signals is fundamentally limited by the background noise from a detector and nonspecific binding. Although digital assays have emerged as a solution, their clinical translation remains challenging due to their reliance on sophisticated single-molecule sensing technologies. Here, we demonstrate that these analog limitations can be overcome using lock-in detection of ensemble signals. By modulating endpoint molecular binding events into periodic optical fluctuations, our approach amplifies weak molecular signals above the background noise floor. Experimental validation demonstrates a three-fold increase in the limit of sensitivity for single-stranded DNA and a one-order-of-magnitude increase for interleukin-6 (IL-6), achieving a limit of detection at the femtomolar level. Compatible with existing assay platforms, this ensemble lock-in biosensing strategy offers a simple yet effective route for the clinical detection of low-abundance biomarkers.
期刊介绍:
Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.