Ravi Mehta,Sondes Ben-Aissa,Kyungae Yang,Elena Chekmeneva,Maria Valdivia-Garcia,Lynn Maslen,Trevor Ferris,Kamil Skirlo,Ewurabena Mills,Vincenzo Sgro,Shiranee Sriskandan,Anthony E. G. Cass
{"title":"Aptamer-Based Fluorescent Assays for Detection of the Host-Response Viral Biomarker 3′-Deoxy-3′,4′-Didehydro-Cytidine","authors":"Ravi Mehta,Sondes Ben-Aissa,Kyungae Yang,Elena Chekmeneva,Maria Valdivia-Garcia,Lynn Maslen,Trevor Ferris,Kamil Skirlo,Ewurabena Mills,Vincenzo Sgro,Shiranee Sriskandan,Anthony E. G. Cass","doi":"10.1021/acs.analchem.6c04805","DOIUrl":null,"url":null,"abstract":"Abstract Improved viral diagnostics are urgently needed to strengthen pandemic preparedness and combat antimicrobial resistance, highlighting the importance of 3′-deoxy-3′,4′-didehydro-cytidine (ddhC), a host-derived, pan-viral biomarker that addresses key limitations of PCR-based diagnostics. Current methods for ddhC measurement rely on liquid chromatography-mass spectrometry (LC−MS) or nuclear magnetic resonance spectroscopy, which are accurate but costly and impractical for rapid or point-of-care testing. Here, we report the development of aptamer-based fluorescent assays for selective ddhC detection. Low-micromolar-affinity DNA aptamers were isolated using capture-systematic evolution of ligands by exponential enrichment (SELEX) and characterised by isothermal titration calorimetry. Using a common core aptamer sequence, three fluorescence assay formats−strand displacement, molecular beacon, and dye displacement−were developed and evaluated. Independent LC−MS analysis demonstrated a strong correlation between creatinine-normalised urinary and serum ddhC concentrations in inpatient samples (R = 0.98, p <0.0001), supporting urine as a non-invasive matrix for ddhC detection. Among the three aptamer-based formats tested, the dye displacement assay exhibited the lowest functional Kd but was limited in urine by inner filter effects, whereas a Cy5-labelled strand displacement assay overcame this limitation and detected ddhC in patient urine with moderate correlation to LC−MS (R = 0.76, p = 0.001). Together, these results establish aptamer-based sensing approaches for ddhC and demonstrate their feasibility in clinical urine samples, providing a foundation for further optimisation toward accessible, non-invasive, and rapid detection of acute viral infection.","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":"160 1","pages":""},"PeriodicalIF":7.3000,"publicationDate":"2026-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acs.analchem.6c04805","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Abstract Improved viral diagnostics are urgently needed to strengthen pandemic preparedness and combat antimicrobial resistance, highlighting the importance of 3′-deoxy-3′,4′-didehydro-cytidine (ddhC), a host-derived, pan-viral biomarker that addresses key limitations of PCR-based diagnostics. Current methods for ddhC measurement rely on liquid chromatography-mass spectrometry (LC−MS) or nuclear magnetic resonance spectroscopy, which are accurate but costly and impractical for rapid or point-of-care testing. Here, we report the development of aptamer-based fluorescent assays for selective ddhC detection. Low-micromolar-affinity DNA aptamers were isolated using capture-systematic evolution of ligands by exponential enrichment (SELEX) and characterised by isothermal titration calorimetry. Using a common core aptamer sequence, three fluorescence assay formats−strand displacement, molecular beacon, and dye displacement−were developed and evaluated. Independent LC−MS analysis demonstrated a strong correlation between creatinine-normalised urinary and serum ddhC concentrations in inpatient samples (R = 0.98, p <0.0001), supporting urine as a non-invasive matrix for ddhC detection. Among the three aptamer-based formats tested, the dye displacement assay exhibited the lowest functional Kd but was limited in urine by inner filter effects, whereas a Cy5-labelled strand displacement assay overcame this limitation and detected ddhC in patient urine with moderate correlation to LC−MS (R = 0.76, p = 0.001). Together, these results establish aptamer-based sensing approaches for ddhC and demonstrate their feasibility in clinical urine samples, providing a foundation for further optimisation toward accessible, non-invasive, and rapid detection of acute viral infection.
期刊介绍:
Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.