Conceptual design of the electron-optics of the magnetic electron recoil gamma-ray spectrometer.

IF 1.6 4区 工程技术 Q3 INSTRUMENTS & INSTRUMENTATION
J H Kunimune, S Huber, S Mackie, E Panontin, N Fensterheim, M Dessena, E Gallo, F Montanari, E Quadrivi, S Vanellone, M Zamboni, J E Rice, R A Tinguely
{"title":"Conceptual design of the electron-optics of the magnetic electron recoil gamma-ray spectrometer.","authors":"J H Kunimune, S Huber, S Mackie, E Panontin, N Fensterheim, M Dessena, E Gallo, F Montanari, E Quadrivi, S Vanellone, M Zamboni, J E Rice, R A Tinguely","doi":"10.1063/5.0350449","DOIUrl":null,"url":null,"abstract":"<p><p>In nuclear fusion reactors, deuterium and tritium are fused together. Most reactions produce a 4He ion and a 14 MeV neutron, while about 2 × 10-5 of them produce a 5He ion and a gamma photon. One of the most important measurements from a fusion reactor is the total fusion power, which can be measured using the 14 MeV neutrons or the gamma-rays. Using both provides two independent measurements, which is valuable for researchers and regulators. Facilities such as JET use scintillators such as LaBr3 to measure gamma-ray emission, but such detectors could struggle with background on high-power reactors such as SPARC and ITER. We propose that a magnetic electron recoil gamma-ray spectrometer (MERGS) can make gamma-ray measurements in these high-background environments. MERGS will consist of a foil that converts photons to electrons via Compton scattering, a magnetic electron-optic system that focuses and disperses the electron beam, and a detector array that counts the electrons and uses their positions to infer their energy. A conceptual design framework of MERGS is presented, along with three numerically optimized electron-optic geometries for three different resolution requirements. Simulations are presented showing that each presented design can meet its requirements. This shows that MERGS can measure the gamma-ray emission spectrum more effectively than scintillators for a variety of price points, enabling improved measurements of fusion power as well as the study of fast ion physics via other nuclear reactions.</p>","PeriodicalId":21111,"journal":{"name":"Review of Scientific Instruments","volume":"97 10","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Review of Scientific Instruments","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0350449","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

Abstract

In nuclear fusion reactors, deuterium and tritium are fused together. Most reactions produce a 4He ion and a 14 MeV neutron, while about 2 × 10-5 of them produce a 5He ion and a gamma photon. One of the most important measurements from a fusion reactor is the total fusion power, which can be measured using the 14 MeV neutrons or the gamma-rays. Using both provides two independent measurements, which is valuable for researchers and regulators. Facilities such as JET use scintillators such as LaBr3 to measure gamma-ray emission, but such detectors could struggle with background on high-power reactors such as SPARC and ITER. We propose that a magnetic electron recoil gamma-ray spectrometer (MERGS) can make gamma-ray measurements in these high-background environments. MERGS will consist of a foil that converts photons to electrons via Compton scattering, a magnetic electron-optic system that focuses and disperses the electron beam, and a detector array that counts the electrons and uses their positions to infer their energy. A conceptual design framework of MERGS is presented, along with three numerically optimized electron-optic geometries for three different resolution requirements. Simulations are presented showing that each presented design can meet its requirements. This shows that MERGS can measure the gamma-ray emission spectrum more effectively than scintillators for a variety of price points, enabling improved measurements of fusion power as well as the study of fast ion physics via other nuclear reactions.

磁电子反冲伽马射线谱仪的电子光学概念设计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Review of Scientific Instruments
Review of Scientific Instruments 工程技术-物理:应用
CiteScore
3.00
自引率
12.50%
发文量
758
审稿时长
2.6 months
期刊介绍: Review of Scientific Instruments, is committed to the publication of advances in scientific instruments, apparatuses, and techniques. RSI seeks to meet the needs of engineers and scientists in physics, chemistry, and the life sciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书