Low-Frequency Operation of Switching Vacuum Arcs

IF 1.6 4区 物理与天体物理 Q3 PHYSICS, FLUIDS & PLASMAS
IEEE Transactions on Plasma Science Pub Date : 2026-10-01 Epub Date: 2026-09-03 DOI:10.1109/TPS.2026.3718945
Dietmar Gentsch;Andreas Lawall;Sergey Gortschakow
{"title":"Low-Frequency Operation of Switching Vacuum Arcs","authors":"Dietmar Gentsch;Andreas Lawall;Sergey Gortschakow","doi":"10.1109/TPS.2026.3718945","DOIUrl":null,"url":null,"abstract":"Conventional applications of vacuum interrupters cover a broad operating frequency range from 60 Hz down to 16.7 Hz, as typically found in power networks and railway electrical systems. With the increasing integration of alternative power sources and the growing complexity of decentralized power networks, new requirements are emerging for vacuum interrupters. Under these evolving grid conditions, fault events may occur at significantly lower frequencies than in traditional systems. Such low-frequency operation can lead to extended arcing times, higher transferred charge, and increased thermal stress on the interrupting contacts. To address these challenges, the present work investigates the arc behavior at frequencies between 2 and 4 Hz and current levels ranging from 70 to 2000 A, using a combination of optical diagnostics and electrical measurements. In addition to high-current experiments, several synthetic test series incorporating transient recovery voltages (TRVs) were conducted to evaluate interruption performance under realistic fault conditions. Furthermore, key aspects of current interruption, such as transferred charge, thermal loading, and contact erosion, were analyzed through numerical simulations and compared with established data obtained at conventional power frequencies. Both the experimental results and the simulation studies demonstrate that vacuum switching arcs exhibit excellent stability and interruption characteristics, confirming that vacuum remains a highly suitable medium for low-frequency current interruption in future power system applications.","PeriodicalId":450,"journal":{"name":"IEEE Transactions on Plasma Science","volume":"54 10","pages":"5220-5226"},"PeriodicalIF":1.6000,"publicationDate":"2026-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Plasma Science","FirstCategoryId":"101","ListUrlMain":"https://ieeexplore.ieee.org/document/11677279/","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/9/3 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PHYSICS, FLUIDS & PLASMAS","Score":null,"Total":0}
引用次数: 0

Abstract

Conventional applications of vacuum interrupters cover a broad operating frequency range from 60 Hz down to 16.7 Hz, as typically found in power networks and railway electrical systems. With the increasing integration of alternative power sources and the growing complexity of decentralized power networks, new requirements are emerging for vacuum interrupters. Under these evolving grid conditions, fault events may occur at significantly lower frequencies than in traditional systems. Such low-frequency operation can lead to extended arcing times, higher transferred charge, and increased thermal stress on the interrupting contacts. To address these challenges, the present work investigates the arc behavior at frequencies between 2 and 4 Hz and current levels ranging from 70 to 2000 A, using a combination of optical diagnostics and electrical measurements. In addition to high-current experiments, several synthetic test series incorporating transient recovery voltages (TRVs) were conducted to evaluate interruption performance under realistic fault conditions. Furthermore, key aspects of current interruption, such as transferred charge, thermal loading, and contact erosion, were analyzed through numerical simulations and compared with established data obtained at conventional power frequencies. Both the experimental results and the simulation studies demonstrate that vacuum switching arcs exhibit excellent stability and interruption characteristics, confirming that vacuum remains a highly suitable medium for low-frequency current interruption in future power system applications.
开关真空电弧的低频运行
真空断路器的传统应用涵盖了从60 Hz到16.7 Hz的广泛工作频率范围,通常用于电网和铁路电气系统。随着替代电源集成度的提高和分散式电网的日益复杂,对真空断路器提出了新的要求。在这些不断变化的电网条件下,故障事件发生的频率可能比传统系统低得多。这种低频操作可能导致电弧时间延长,转移电荷增加,并增加中断触点上的热应力。为了解决这些挑战,目前的研究工作使用光学诊断和电气测量相结合的方法,研究了频率在2到4 Hz之间,电流水平在70到2000 A之间的电弧行为。除了大电流实验外,还进行了几个包含瞬态恢复电压(TRVs)的综合测试系列,以评估实际故障条件下的中断性能。此外,通过数值模拟分析了电流中断的关键方面,如转移电荷、热负荷和接触侵蚀,并与常规功率频率下获得的既定数据进行了比较。实验结果和仿真研究都表明,真空开关电弧具有优异的稳定性和中断特性,证实了真空在未来电力系统中仍然是一种非常适合低频电流中断的介质。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Plasma Science
IEEE Transactions on Plasma Science 物理-物理:流体与等离子体
CiteScore
3.00
自引率
20.00%
发文量
538
审稿时长
3.8 months
期刊介绍: The scope covers all aspects of the theory and application of plasma science. It includes the following areas: magnetohydrodynamics; thermionics and plasma diodes; basic plasma phenomena; gaseous electronics; microwave/plasma interaction; electron, ion, and plasma sources; space plasmas; intense electron and ion beams; laser-plasma interactions; plasma diagnostics; plasma chemistry and processing; solid-state plasmas; plasma heating; plasma for controlled fusion research; high energy density plasmas; industrial/commercial applications of plasma physics; plasma waves and instabilities; and high power microwave and submillimeter wave generation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书