Determination of cadmium, lead and mercury in cannabis flowers by microwave plasma atomic emission spectrometry.

IF 1.7
Mónica Pereira, Ignacio Machado, Florencia Tissot
{"title":"Determination of cadmium, lead and mercury in cannabis flowers by microwave plasma atomic emission spectrometry.","authors":"Mónica Pereira, Ignacio Machado, Florencia Tissot","doi":"10.1093/jaoacint/qsag088","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The rapid expansion of legal medicinal and recreational cannabis markets has increased the need for quality control strategies and regulatory monitoring of contaminants in cannabis products. Toxic elements are of particular concern because cannabis plants can accumulate trace metals from environmental and cultivation sources.</p><p><strong>Objective: </strong>To evaluate microwave plasma atomic emission spectrometry (MP AES) as a cost-effective alternative to conventional argon plasma-based techniques for the determination of cadmium (Cd), lead (Pb), and mercury (Hg) in cannabis flowers.</p><p><strong>Methods: </strong>Samples were prepared by microwave-assisted acid digestion using nitric acid. Cd and Pb were determined sequentially by MP AES, while Hg was quantified using a dedicated cold vapor generation coupled to MP AES (CV-MP AES). The analytical methodologies were optimized and validated according to Eurachem guidelines.</p><p><strong>Results: </strong>Limits of quantification were 0.40 µg/g for Cd, 0.18 µg/g for Pb, and 0.015 µg/g for Hg. Accuracy was evaluated using reference materials and spiked samples, with recoveries of 95-101% and 81-90%, respectively, and relative standard deviations below 15%. Good linearity was achieved (R² > 0.999). The methodologies were applied to 30 commercial cannabis flower samples, where Cd and Hg were not detected, and Pb was quantified at 2.12 ± 0.13 µg/g.</p><p><strong>Conclusions: </strong>MP AES and CV-MP AES provide adequate accuracy and precision for the determination of Cd, Pb, and Hg in cannabis flowers. The proposed methodologies represent a practical, cost-effective, and sustainable alternative to argon-based plasma techniques for routine quality control and compliance testing of cannabis products.</p>","PeriodicalId":94064,"journal":{"name":"Journal of AOAC International","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2026-09-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of AOAC International","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jaoacint/qsag088","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The rapid expansion of legal medicinal and recreational cannabis markets has increased the need for quality control strategies and regulatory monitoring of contaminants in cannabis products. Toxic elements are of particular concern because cannabis plants can accumulate trace metals from environmental and cultivation sources.

Objective: To evaluate microwave plasma atomic emission spectrometry (MP AES) as a cost-effective alternative to conventional argon plasma-based techniques for the determination of cadmium (Cd), lead (Pb), and mercury (Hg) in cannabis flowers.

Methods: Samples were prepared by microwave-assisted acid digestion using nitric acid. Cd and Pb were determined sequentially by MP AES, while Hg was quantified using a dedicated cold vapor generation coupled to MP AES (CV-MP AES). The analytical methodologies were optimized and validated according to Eurachem guidelines.

Results: Limits of quantification were 0.40 µg/g for Cd, 0.18 µg/g for Pb, and 0.015 µg/g for Hg. Accuracy was evaluated using reference materials and spiked samples, with recoveries of 95-101% and 81-90%, respectively, and relative standard deviations below 15%. Good linearity was achieved (R² > 0.999). The methodologies were applied to 30 commercial cannabis flower samples, where Cd and Hg were not detected, and Pb was quantified at 2.12 ± 0.13 µg/g.

Conclusions: MP AES and CV-MP AES provide adequate accuracy and precision for the determination of Cd, Pb, and Hg in cannabis flowers. The proposed methodologies represent a practical, cost-effective, and sustainable alternative to argon-based plasma techniques for routine quality control and compliance testing of cannabis products.

微波等离子体原子发射光谱法测定大麻花中的镉、铅和汞。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书