Mechanical evaluation of 3D-printed above-knee prosthetic sockets using a biofidelic hyperelastic silicone limb surrogate.

IF 2.4 4区 医学 Q3 ENGINEERING, BIOMEDICAL
Pimpet Sratong-On, Onanong Sukjai, Sawanya Suwannawong, Hui Lin Foo, Kaylen Lim, Chuen Kum Lee, Kazuhiko Sasaki
{"title":"Mechanical evaluation of 3D-printed above-knee prosthetic sockets using a biofidelic hyperelastic silicone limb surrogate.","authors":"Pimpet Sratong-On, Onanong Sukjai, Sawanya Suwannawong, Hui Lin Foo, Kaylen Lim, Chuen Kum Lee, Kazuhiko Sasaki","doi":"10.1088/1873-4030/aeaba3","DOIUrl":null,"url":null,"abstract":"<p><p>Rigid limb surrogates transfer full mechanical loads directly to the prosthetic socket during structural testing, causing premature distal failure and underestimating of actual load capacity. In contrast, soft-compliant surrogates buffer applied loads and enables realistic structural deformation. This study investigates: (i) the influence of rigid Plaster of Paris (PoP) versus biofidelic hyperelastic silicone surrogates on the structural load capacity of 3D-printed transfemoral prosthetic sockets; and (ii) orientation-dependent structural deformation and failure behaviors arising from asymmetric transfemoral anatomy. Sockets encapsulated with PoP and silicone surrogates were evaluated under ((ISO 10328:2016) 2016 Prosthetics-Structural testing of lower-limb prostheses-Requirements and test methods (International Organization for Standardization)) static loading (Condition II) at two loading alignments: toe-off and toe-towards-lateral (90° laterally rotated) configurations. Initial testing with 3D-printed bespoke commercial (BC) connectors induced premature distal connector failure; however, under toe-towards-lateral loading, socket/silicone assemblies exhibited a 4.47-fold greater displacement and a 72.46% higher ultimate force than socket/PoP assemblies. Sockets with an enlarged BC connector encapsulated in the silicone surrogate showed distinct force-displacement hysteresis loops under toe-towards-lateral loading, indicating energy dissipation. Crucially, enlarging the BC connector shifted the failure site from interlayer delamination at the distal end under toe-off to trans-layer fracture across the lateral socket wall. Conversely, socket/PoP assemblies consistently failed at the enlarged BC distal connector regardless of loading orientation. Finite element analysis confirmed non-compliant, uniform contact pressure in socket/PoP assemblies, whereas the silicone surrogate produced compliant pressure gradients. Loading orientation significantly affected the structural deformation (<i>p</i>< 0.05) of socket/silicone assemblies: toe-towards-lateral loading induced two-fold greater deformation and an 18.95% higher ultimate force than under toe-off loading due to the thicker lateral silicone resulting from asymmetric limb geometry. These findings demonstrate that a biofidelic hyperelastic surrogate buffers stress and redistributes contact pressure similar to biological soft tissue, establishing a more accurate pre-clinical framework for evaluating 3D-printed prosthetic socket strength.</p>","PeriodicalId":49836,"journal":{"name":"Medical Engineering & Physics","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2026-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Engineering & Physics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1873-4030/aeaba3","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Rigid limb surrogates transfer full mechanical loads directly to the prosthetic socket during structural testing, causing premature distal failure and underestimating of actual load capacity. In contrast, soft-compliant surrogates buffer applied loads and enables realistic structural deformation. This study investigates: (i) the influence of rigid Plaster of Paris (PoP) versus biofidelic hyperelastic silicone surrogates on the structural load capacity of 3D-printed transfemoral prosthetic sockets; and (ii) orientation-dependent structural deformation and failure behaviors arising from asymmetric transfemoral anatomy. Sockets encapsulated with PoP and silicone surrogates were evaluated under ((ISO 10328:2016) 2016 Prosthetics-Structural testing of lower-limb prostheses-Requirements and test methods (International Organization for Standardization)) static loading (Condition II) at two loading alignments: toe-off and toe-towards-lateral (90° laterally rotated) configurations. Initial testing with 3D-printed bespoke commercial (BC) connectors induced premature distal connector failure; however, under toe-towards-lateral loading, socket/silicone assemblies exhibited a 4.47-fold greater displacement and a 72.46% higher ultimate force than socket/PoP assemblies. Sockets with an enlarged BC connector encapsulated in the silicone surrogate showed distinct force-displacement hysteresis loops under toe-towards-lateral loading, indicating energy dissipation. Crucially, enlarging the BC connector shifted the failure site from interlayer delamination at the distal end under toe-off to trans-layer fracture across the lateral socket wall. Conversely, socket/PoP assemblies consistently failed at the enlarged BC distal connector regardless of loading orientation. Finite element analysis confirmed non-compliant, uniform contact pressure in socket/PoP assemblies, whereas the silicone surrogate produced compliant pressure gradients. Loading orientation significantly affected the structural deformation (p< 0.05) of socket/silicone assemblies: toe-towards-lateral loading induced two-fold greater deformation and an 18.95% higher ultimate force than under toe-off loading due to the thicker lateral silicone resulting from asymmetric limb geometry. These findings demonstrate that a biofidelic hyperelastic surrogate buffers stress and redistributes contact pressure similar to biological soft tissue, establishing a more accurate pre-clinical framework for evaluating 3D-printed prosthetic socket strength.

使用仿生超弹性硅胶假肢替代物对3d打印膝上假体进行力学评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical Engineering & Physics
Medical Engineering & Physics 工程技术-工程:生物医学
CiteScore
4.30
自引率
4.50%
发文量
172
审稿时长
3.0 months
期刊介绍: Medical Engineering & Physics provides a forum for the publication of the latest developments in biomedical engineering, and reflects the essential multidisciplinary nature of the subject. The journal publishes in-depth critical reviews, scientific papers and technical notes. Our focus encompasses the application of the basic principles of physics and engineering to the development of medical devices and technology, with the ultimate aim of producing improvements in the quality of health care.Topics covered include biomechanics, biomaterials, mechanobiology, rehabilitation engineering, biomedical signal processing and medical device development. Medical Engineering & Physics aims to keep both engineers and clinicians abreast of the latest applications of technology to health care.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书