Image-enhanced autonomous navigation in intestinal robotics: a threshold-triggered approach combining dark-area localization and morphological contour guidance short title: enhancing visibility and navigation precision in confined spaces.
{"title":"Image-enhanced autonomous navigation in intestinal robotics: a threshold-triggered approach combining dark-area localization and morphological contour guidance short title: enhancing visibility and navigation precision in confined spaces.","authors":"Shiwei Wang, Junying Yuan, Haoran Deng, Hanyu Deng, Xiuquan Yue, Tianshi Zhang, Shenjin Chen, Haishan Chen","doi":"10.1088/1873-4030/aeaba4","DOIUrl":null,"url":null,"abstract":"<p><p>Robotic endoscopy offers a potential route to autonomous gastrointestinal navigation. However, autonomous intestinal navigation is hindered by non-rigid lumen deformation and visual degradation from specular reflections, which compromise accurate perception and stable control. We propose a threshold-triggered, vision-driven framework incorporating Navier-Stokes-based highlight suppression. Algorithmically, the system is governed by a threshold-triggered mechanism that acts as a conditional perception gate, dynamically alternating between a lightweight 'dark-area guidance' algorithm for approximately centered navigation and a more detailed 'contour-based guidance' pipeline for corrective steering. The switching policy avoids executing highlight suppression and morphological contour processing in every frame. In phantom-based trials, the system achieved an average speed of 3.10 cm s<sup>-1</sup>on the triangular path. Highlight suppression increased the proportion of frames with normalized center error below 0.1 from 65% to 71%, below 0.2 from 95% to 97%, and below 0.3 from 98% to 100%. The adaptive mechanism decreased runtime by approximately 2% compared to continuous contour processing. Although this absolute reduction was modest, it recovered approximately 89% of the runtime difference between the contour-only and dark-area-only baselines. These phantom-based results support conditional perception allocation while keeping average processing time close to that of lightweight navigation.</p>","PeriodicalId":49836,"journal":{"name":"Medical Engineering & Physics","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2026-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Engineering & Physics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1873-4030/aeaba4","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Robotic endoscopy offers a potential route to autonomous gastrointestinal navigation. However, autonomous intestinal navigation is hindered by non-rigid lumen deformation and visual degradation from specular reflections, which compromise accurate perception and stable control. We propose a threshold-triggered, vision-driven framework incorporating Navier-Stokes-based highlight suppression. Algorithmically, the system is governed by a threshold-triggered mechanism that acts as a conditional perception gate, dynamically alternating between a lightweight 'dark-area guidance' algorithm for approximately centered navigation and a more detailed 'contour-based guidance' pipeline for corrective steering. The switching policy avoids executing highlight suppression and morphological contour processing in every frame. In phantom-based trials, the system achieved an average speed of 3.10 cm s-1on the triangular path. Highlight suppression increased the proportion of frames with normalized center error below 0.1 from 65% to 71%, below 0.2 from 95% to 97%, and below 0.3 from 98% to 100%. The adaptive mechanism decreased runtime by approximately 2% compared to continuous contour processing. Although this absolute reduction was modest, it recovered approximately 89% of the runtime difference between the contour-only and dark-area-only baselines. These phantom-based results support conditional perception allocation while keeping average processing time close to that of lightweight navigation.
期刊介绍:
Medical Engineering & Physics provides a forum for the publication of the latest developments in biomedical engineering, and reflects the essential multidisciplinary nature of the subject. The journal publishes in-depth critical reviews, scientific papers and technical notes. Our focus encompasses the application of the basic principles of physics and engineering to the development of medical devices and technology, with the ultimate aim of producing improvements in the quality of health care.Topics covered include biomechanics, biomaterials, mechanobiology, rehabilitation engineering, biomedical signal processing and medical device development. Medical Engineering & Physics aims to keep both engineers and clinicians abreast of the latest applications of technology to health care.