Admittance-spectrum-based dual-resonance feature prediction and target-oriented design of annular piezoelectric ceramics for conducted EMI suppression

IF 6.1 2区 工程技术 Q1 ENGINEERING, MULTIDISCIPLINARY
Jiahao Wen, Mengxia Zhou, Wei Yan, Hanqing Duan, Xinyi Liu, Shuo Dong, Yu Wang
{"title":"Admittance-spectrum-based dual-resonance feature prediction and target-oriented design of annular piezoelectric ceramics for conducted EMI suppression","authors":"Jiahao Wen,&nbsp;Mengxia Zhou,&nbsp;Wei Yan,&nbsp;Hanqing Duan,&nbsp;Xinyi Liu,&nbsp;Shuo Dong,&nbsp;Yu Wang","doi":"10.1016/j.measurement.2026.123214","DOIUrl":null,"url":null,"abstract":"<div><div>The capacitance of Y capacitors is limited by leakage-current requirements, whereas high-inductance common-mode chokes (CMCs) increase filter mass and volume. This study develops a measurement-informed closed-loop framework linking measured conducted electromagnetic interference (EMI) targets to dual-resonance prediction, inverse geometry design, commercial-size mapping, and experimental validation of annular lead zirconate titanate (PZT) ceramics. A full-factorial finite-element method (FEM) dataset of 1232 geometries was used to model the first two resonance frequencies and peak admittances using six surrogates under strict nested fivefold cross-validation. An output-specific ensemble of least-squares boosting (LSBoost) and a multilayer perceptron (MLP) achieved pooled mean absolute percentage errors of 0.161%, 0.464%, 0.326%, and 1.292% for <em>f</em><sub>1</sub>, <em>Y</em><sub>1</sub>, <em>f</em><sub>2</sub>, and <em>Y</em><sub>2</sub>, respectively. For measured targets at 162 and 486 kHz, particle swarm optimization identified an inverse-design solution that was mapped to a commercial PZT ring of 4.50/1.50/2.00 mm (outer radius/inner radius/thickness). Independent FEM and admittance measurements yielded resonance-frequency errors of 0.28% and 0.29%, with peak-admittance discrepancies of 12.76% and 9.65%. Without an external CMC, the PZT ring provided 1.45 and 1.35 dB greater attenuation than a 680-pF Y capacitor at the target frequencies; two additional nominally identical rings showed the same advantage. In complete-filter tests, the 2.2-mH CMC–PZT configuration provided 2.81 and 5.14 dB greater attenuation than the 20-mH CMC–Y-capacitor reference. Because the CMC values differed, these are configuration-level results; for the implemented passive-component sets, the PZT-assisted set was 73.6% lighter and had a 61.8% smaller estimated volume.</div></div>","PeriodicalId":18349,"journal":{"name":"Measurement","volume":"291 ","pages":"Article 123214"},"PeriodicalIF":6.1000,"publicationDate":"2026-09-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measurement","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0263224126029246","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

The capacitance of Y capacitors is limited by leakage-current requirements, whereas high-inductance common-mode chokes (CMCs) increase filter mass and volume. This study develops a measurement-informed closed-loop framework linking measured conducted electromagnetic interference (EMI) targets to dual-resonance prediction, inverse geometry design, commercial-size mapping, and experimental validation of annular lead zirconate titanate (PZT) ceramics. A full-factorial finite-element method (FEM) dataset of 1232 geometries was used to model the first two resonance frequencies and peak admittances using six surrogates under strict nested fivefold cross-validation. An output-specific ensemble of least-squares boosting (LSBoost) and a multilayer perceptron (MLP) achieved pooled mean absolute percentage errors of 0.161%, 0.464%, 0.326%, and 1.292% for f1, Y1, f2, and Y2, respectively. For measured targets at 162 and 486 kHz, particle swarm optimization identified an inverse-design solution that was mapped to a commercial PZT ring of 4.50/1.50/2.00 mm (outer radius/inner radius/thickness). Independent FEM and admittance measurements yielded resonance-frequency errors of 0.28% and 0.29%, with peak-admittance discrepancies of 12.76% and 9.65%. Without an external CMC, the PZT ring provided 1.45 and 1.35 dB greater attenuation than a 680-pF Y capacitor at the target frequencies; two additional nominally identical rings showed the same advantage. In complete-filter tests, the 2.2-mH CMC–PZT configuration provided 2.81 and 5.14 dB greater attenuation than the 20-mH CMC–Y-capacitor reference. Because the CMC values differed, these are configuration-level results; for the implemented passive-component sets, the PZT-assisted set was 73.6% lighter and had a 61.8% smaller estimated volume.
基于导纳-频谱的环形压电陶瓷传导电磁干扰双共振特征预测与目标导向设计
Y型电容器的电容受到漏电流要求的限制,而高电感共模扼流圈(cmc)增加了滤波器的质量和体积。本研究开发了一个测量信息闭环框架,将测量的传导电磁干扰(EMI)目标与双共振预测、逆几何设计、商业尺寸测绘和环形锆钛酸铅(PZT)陶瓷的实验验证联系起来。利用1232个几何图形的全因子有限元方法(FEM)数据集,在严格嵌套的五重交叉验证下,使用6个替代因子对前两个共振频率和峰值导纳进行了建模。对于f1、Y1、f2和Y2,最小二乘增强(LSBoost)和多层感知器(MLP)的输出特定集成分别实现了0.161%、0.464%、0.326%和1.292%的汇总平均绝对百分比误差。对于162和486 kHz的测量目标,粒子群优化确定了一个反设计方案,该方案被映射到4.50/1.50/2.00 mm(外半径/内半径/厚度)的商业PZT环。独立有限元和导纳测量的共振频率误差分别为0.28%和0.29%,峰值导纳误差分别为12.76%和9.65%。在没有外部CMC的情况下,PZT环在目标频率上的衰减比680-pF Y电容器高1.45和1.35 dB;另外两个名义上相同的环显示出同样的优势。在全滤波器测试中,2.2 mh CMC-PZT配置的衰减比20 mh cmc - y电容器参考值高2.81和5.14 dB。由于CMC值不同,这些是配置级结果;对于已实施的被动组件组,pzt辅助组的重量减轻了73.6%,估计体积减小了61.8%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Measurement
Measurement 工程技术-工程:综合
CiteScore
10.20
自引率
12.50%
发文量
1589
审稿时长
12.1 months
期刊介绍: Contributions are invited on novel achievements in all fields of measurement and instrumentation science and technology. Authors are encouraged to submit novel material, whose ultimate goal is an advancement in the state of the art of: measurement and metrology fundamentals, sensors, measurement instruments, measurement and estimation techniques, measurement data processing and fusion algorithms, evaluation procedures and methodologies for plants and industrial processes, performance analysis of systems, processes and algorithms, mathematical models for measurement-oriented purposes, distributed measurement systems in a connected world.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书