Portable RGB-D stabilometry for unsupervised postural assessment in Antarctic field conditions.

IF 2.4 4区 医学 Q3 ENGINEERING, BIOMEDICAL
Petr Volf, Marek Sokol, Lýdie Leová, Jan Hejda, Patrik Kutílek
{"title":"Portable RGB-D stabilometry for unsupervised postural assessment in Antarctic field conditions.","authors":"Petr Volf, Marek Sokol, Lýdie Leová, Jan Hejda, Patrik Kutílek","doi":"10.1088/1873-4030/aea621","DOIUrl":null,"url":null,"abstract":"<p><p>Portable quantification of postural sway remains challenging in remote and resource-limited environments where laboratory force platforms and motion-capture systems are impractical. We evaluated an autonomous RGB-D stabilometry workflow during an Antarctic expedition by comparing camera-derived center-of-mass (CoM) sway with a portable center-of-pressure (CoP) reference and testing leave-one-subject-out calibration. Thirteen participants performed modified Romberg trials while an Intel RealSense D455 camera and a Wii Balance Board (WBB) recorded postural data. Full-body CoM trajectories were reconstructed from three-dimensional landmarks; facial-landmark head tracking was evaluated as a secondary fallback modality. In total, 192 quality-controlled WBB-camera pairs were analyzed. Temporal-alignment diagnostics showed strong anteroposterior signal overlap with the CoP reference (median post-lag Pearson= 0.847-0.929 for full-body tracking;= 0.825-0.905 for head tracking). Raw full-body metrics underestimated root-mean-square anteroposterior sway (bias =5.62 mm) and overestimated mean velocity (bias = 8.67 mm s). Passing-Bablok calibration reduced RMS AP bias relative to the WBB reference to 0.01 mm and narrowed the width of the limits of agreement from 12.15 to 7.15 mm. After empirical mapping, the inter-method reliability of Rambling RMS AP sway relative to the WBB reference was excellent (ICC(2,1) = 0.956), whereas mediolateral outcomes were less reliable and should be interpreted as exploratory in this camera configuration, likely reflecting lower ML amplitude and three-quarter camera geometry. Clock-based fixed windows yielded lower correlations, whereas a single global acquisition-latency correction applied identically to all trials, without per-trial window optimization, recovered correlations close to those of the optimized analysis. All estimates are relative to the portable WBB field reference rather than a laboratory-grade standard, and the calibration is a task- and setup-specific empirical mapping, not a universal biomechanical transformation.</p>","PeriodicalId":49836,"journal":{"name":"Medical Engineering & Physics","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2026-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Engineering & Physics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1873-4030/aea621","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Portable quantification of postural sway remains challenging in remote and resource-limited environments where laboratory force platforms and motion-capture systems are impractical. We evaluated an autonomous RGB-D stabilometry workflow during an Antarctic expedition by comparing camera-derived center-of-mass (CoM) sway with a portable center-of-pressure (CoP) reference and testing leave-one-subject-out calibration. Thirteen participants performed modified Romberg trials while an Intel RealSense D455 camera and a Wii Balance Board (WBB) recorded postural data. Full-body CoM trajectories were reconstructed from three-dimensional landmarks; facial-landmark head tracking was evaluated as a secondary fallback modality. In total, 192 quality-controlled WBB-camera pairs were analyzed. Temporal-alignment diagnostics showed strong anteroposterior signal overlap with the CoP reference (median post-lag Pearson= 0.847-0.929 for full-body tracking;= 0.825-0.905 for head tracking). Raw full-body metrics underestimated root-mean-square anteroposterior sway (bias =5.62 mm) and overestimated mean velocity (bias = 8.67 mm s). Passing-Bablok calibration reduced RMS AP bias relative to the WBB reference to 0.01 mm and narrowed the width of the limits of agreement from 12.15 to 7.15 mm. After empirical mapping, the inter-method reliability of Rambling RMS AP sway relative to the WBB reference was excellent (ICC(2,1) = 0.956), whereas mediolateral outcomes were less reliable and should be interpreted as exploratory in this camera configuration, likely reflecting lower ML amplitude and three-quarter camera geometry. Clock-based fixed windows yielded lower correlations, whereas a single global acquisition-latency correction applied identically to all trials, without per-trial window optimization, recovered correlations close to those of the optimized analysis. All estimates are relative to the portable WBB field reference rather than a laboratory-grade standard, and the calibration is a task- and setup-specific empirical mapping, not a universal biomechanical transformation.

用于南极野外条件下无监督姿势评估的便携式RGB-D稳定测量仪。
在偏远和资源有限的环境中,实验室力平台和动作捕捉系统不切实际,便携式姿势摇摆量化仍然具有挑战性。在南极考察期间,我们通过比较相机导出的质心(CoM)摆动与便携式压力中心(CoP)参考和测试留一个主体校准,评估了自主RGB-D稳定测量工作流程。13名参与者进行了改进的Romberg试验,同时使用英特尔RealSense D455相机和Wii平衡板(WBB)记录姿势数据。由三维地标重建全身CoM轨迹;面部地标头部跟踪被评估为次要的后备模式。总共分析了192对质量控制的WBB-camera对。时间对准诊断显示与CoP参考有很强的前后信号重叠(全身跟踪的滞后后Pearson中位数r = 0.847-0.929,头部跟踪的r = 0.825-0.905)。原始的全身指标低估了均方根前后摇摆(偏差= -5.62 mm)和高估了平均速度(偏差= 8.67 mm/s)。pass - bablok校准将相对于WBB参考的RMS AP偏差降低到0.01 mm,并将一致性限制的宽度从12.15 mm缩小到7.15 mm。经过经验映射,Rambling RMS AP摆动相对于WBB参考的方法间可靠性非常好(ICC(2,1) = 0.956),而中外侧结果不太可靠,应该解释为探索性的,在这种相机配置中,可能反映了较低的ML振幅和四分之三相机几何形状。基于时钟的固定窗口产生较低的相关性,而对所有试验应用相同的单一全局获取延迟校正,而不进行每次试验窗口优化,恢复的相关性接近优化分析的相关性。所有估计都是相对于便携式WBB现场参考,而不是实验室级标准,校准是特定任务和设置的经验映射,而不是通用的生物力学转换。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical Engineering & Physics
Medical Engineering & Physics 工程技术-工程:生物医学
CiteScore
4.30
自引率
4.50%
发文量
172
审稿时长
3.0 months
期刊介绍: Medical Engineering & Physics provides a forum for the publication of the latest developments in biomedical engineering, and reflects the essential multidisciplinary nature of the subject. The journal publishes in-depth critical reviews, scientific papers and technical notes. Our focus encompasses the application of the basic principles of physics and engineering to the development of medical devices and technology, with the ultimate aim of producing improvements in the quality of health care.Topics covered include biomechanics, biomaterials, mechanobiology, rehabilitation engineering, biomedical signal processing and medical device development. Medical Engineering & Physics aims to keep both engineers and clinicians abreast of the latest applications of technology to health care.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书