Evaluating Substitution of Hazardous Solvents in USP Monograph HPLC Methods.

IF 1.7
Weidong Zhao, Koushik Mondal, Praveen Thakur, David Mande, Nagaraju Katepally, Parise Naga Malleswari, Lakshmi Kanth Juluru, Suresh Kumar Sheik, Yvs Veerendra, Arunima Pola, Greg Winter, Paolo Lecchi, Mrunal A Jaywant, Michael Ambrose
{"title":"Evaluating Substitution of Hazardous Solvents in USP Monograph HPLC Methods.","authors":"Weidong Zhao, Koushik Mondal, Praveen Thakur, David Mande, Nagaraju Katepally, Parise Naga Malleswari, Lakshmi Kanth Juluru, Suresh Kumar Sheik, Yvs Veerendra, Arunima Pola, Greg Winter, Paolo Lecchi, Mrunal A Jaywant, Michael Ambrose","doi":"10.1093/jaoacint/qsag071","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Hazardous solvents, such as dichloromethane (DCM), n-hexane, and acetonitrile (ACN), are widely used in HPLC methods, posing significant health and environmental risks.</p><p><strong>Objective: </strong>To evaluate the feasibility and impact of substituting hazardous solvents with greener alternatives in USP monograph methods.</p><p><strong>Methods: </strong>Six high-impact solvents were identified from USP-NF monographs. Two representative monographs per solvent were selected. Substitution strategies were assessed, and performance was compared using system suitability and sample acceptance criteria. Greenness improvement was evaluated using the Analytical GREEnness (AGREE) metric.</p><p><strong>Results: </strong>Performance remained equivalent across all twelve substitution cases. In almost every instance, only the mobile phase required modification, either by direct substitution or by adjusting the solvent-to-buffer ratio, except for one case that required a minor adjustment in column temperature. The AGREE Greenness metric increased by 18-65% in ten out of twelve cases; for n-hexane, improvements were modest at just 6% when replaced with n-heptane but exceeded 40% when substituted with supercritical CO₂.</p><p><strong>Conclusions: </strong>Greener solvents are highly likely to replace hazardous solvents used in compendial chromatography methods without loss of performance.</p><p><strong>Highlights: </strong>Demonstrated performance equivalency for greener solvent substitutions; Quantified greenness improvements using AGREE; Discussed strategies to implement greener solvents in USP monograph methods.</p>","PeriodicalId":94064,"journal":{"name":"Journal of AOAC International","volume":" ","pages":""},"PeriodicalIF":1.7000,"publicationDate":"2026-09-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of AOAC International","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jaoacint/qsag071","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Hazardous solvents, such as dichloromethane (DCM), n-hexane, and acetonitrile (ACN), are widely used in HPLC methods, posing significant health and environmental risks.

Objective: To evaluate the feasibility and impact of substituting hazardous solvents with greener alternatives in USP monograph methods.

Methods: Six high-impact solvents were identified from USP-NF monographs. Two representative monographs per solvent were selected. Substitution strategies were assessed, and performance was compared using system suitability and sample acceptance criteria. Greenness improvement was evaluated using the Analytical GREEnness (AGREE) metric.

Results: Performance remained equivalent across all twelve substitution cases. In almost every instance, only the mobile phase required modification, either by direct substitution or by adjusting the solvent-to-buffer ratio, except for one case that required a minor adjustment in column temperature. The AGREE Greenness metric increased by 18-65% in ten out of twelve cases; for n-hexane, improvements were modest at just 6% when replaced with n-heptane but exceeded 40% when substituted with supercritical CO₂.

Conclusions: Greener solvents are highly likely to replace hazardous solvents used in compendial chromatography methods without loss of performance.

Highlights: Demonstrated performance equivalency for greener solvent substitutions; Quantified greenness improvements using AGREE; Discussed strategies to implement greener solvents in USP monograph methods.

评价USP各论高效液相色谱法中有害溶剂的替代。
背景:二氯甲烷(DCM)、正己烷和乙腈(ACN)等有害溶剂在高效液相色谱法中被广泛使用,对健康和环境构成重大风险。目的:评价在USP各论法中以绿色溶剂替代有害溶剂的可行性及影响。方法:从USP-NF各论中鉴定出6种高影响溶剂。每种溶剂选出两本具有代表性的专著。评估了替代策略,并使用系统适用性和样本接受标准对其性能进行了比较。使用分析绿色度(AGREE)度量来评估绿色改善。结果:在所有12个替换病例中,性能保持相同。在几乎每一种情况下,只有流动相需要修改,通过直接替代或通过调整溶剂与缓冲液的比例,除了一个情况,需要在柱温进行轻微的调整。在12个案例中,有10个案例的AGREE绿色指标提高了18-65%;对于正己烷,当被正庚烷取代时,改善幅度不大,仅为6%,但当被超临界二氧化碳取代时,改善幅度超过40%。结论:绿色溶剂极有可能取代药典色谱法中使用的有害溶剂而不损失性能。亮点:证明了绿色溶剂替代的性能等效;使用AGREE量化环保改善;讨论了在USP各论方法中实施绿色溶剂的策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书