Biomechanical evaluation of the temporomandibular joint following multi-directional orthognathic surgery: a finite element analysis.

IF 2.4 4区 医学 Q3 ENGINEERING, BIOMEDICAL
Sema Dutar Çomurlu, Ümit Ertaş, İrfan Kaymaz, Osman Yavuz
{"title":"Biomechanical evaluation of the temporomandibular joint following multi-directional orthognathic surgery: a finite element analysis.","authors":"Sema Dutar Çomurlu, Ümit Ertaş, İrfan Kaymaz, Osman Yavuz","doi":"10.1088/1873-4030/aea225","DOIUrl":null,"url":null,"abstract":"<p><p>This study investigated the biomechanical effects of multidirectional maxillary repositioning combined with mandibular advancement and rotation on temporomandibular joint (TMJ) components using patient-specific finite element analysis. Patient-specific three-dimensional models, reconstructed from the preoperative computed tomography (CT) data of six distinct patients presenting with varying dentofacial deformities, were used to generate the six virtual orthognathic surgery configurations, including isolated mandibular advancement, bimaxillary repositioning, vertical maxillary movements, and asymmetric rotational components. Under identical loading and boundary conditions, stress distributions in the condyle, articular disc, and glenoid fossa were evaluated. The results showed that isolated mandibular advancement produced higher and more asymmetric stress concentrations, whereas bimaxillary configurations resulted in lower and more homogeneous stress distribution. Vertical maxillary repositioning and rotational asymmetry increased unilateral and unbalanced joint loading. These findings suggest that bimaxillary surgical approaches may provide a more favorable biomechanical environment for the TMJ, while large mandibular advancements and rotational components should be planned cautiously because of their potential to increase postoperative joint loading.</p>","PeriodicalId":49836,"journal":{"name":"Medical Engineering & Physics","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2026-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Engineering & Physics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1873-4030/aea225","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This study investigated the biomechanical effects of multidirectional maxillary repositioning combined with mandibular advancement and rotation on temporomandibular joint (TMJ) components using patient-specific finite element analysis. Patient-specific three-dimensional models, reconstructed from the preoperative computed tomography (CT) data of six distinct patients presenting with varying dentofacial deformities, were used to generate the six virtual orthognathic surgery configurations, including isolated mandibular advancement, bimaxillary repositioning, vertical maxillary movements, and asymmetric rotational components. Under identical loading and boundary conditions, stress distributions in the condyle, articular disc, and glenoid fossa were evaluated. The results showed that isolated mandibular advancement produced higher and more asymmetric stress concentrations, whereas bimaxillary configurations resulted in lower and more homogeneous stress distribution. Vertical maxillary repositioning and rotational asymmetry increased unilateral and unbalanced joint loading. These findings suggest that bimaxillary surgical approaches may provide a more favorable biomechanical environment for the TMJ, while large mandibular advancements and rotational components should be planned cautiously because of their potential to increase postoperative joint loading.

多方向正颌手术后颞下颌关节的生物力学评价:有限元分析。
本研究采用患者特异性有限元分析,探讨上颌多向移位联合下颌前移和旋转对颞下颌关节(TMJ)构件的生物力学影响。根据6例具有不同牙面畸形的不同患者的术前计算机断层扫描(CT)数据重建的患者特异性三维模型,用于生成六种虚拟正颌手术配置,包括分离的下颌前移、双颌重新定位、上颌垂直运动和不对称旋转部件。 ;在相同的载荷和边界条件下,髁突应力分布,评估关节盘和关节盂窝。结果表明,单独的下颌骨进动会产生更高且更不对称的应力集中,而双颌进动会产生更低且更均匀的应力分布。上颌垂直重新定位和旋转不对称增加单边和不平衡关节负荷。这些发现表明,双颌手术入路可能为TMJ提供更有利的生物力学环境,而大的下颌推进和旋转部件应谨慎规划,因为它们可能增加术后关节负荷。 。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical Engineering & Physics
Medical Engineering & Physics 工程技术-工程:生物医学
CiteScore
4.30
自引率
4.50%
发文量
172
审稿时长
3.0 months
期刊介绍: Medical Engineering & Physics provides a forum for the publication of the latest developments in biomedical engineering, and reflects the essential multidisciplinary nature of the subject. The journal publishes in-depth critical reviews, scientific papers and technical notes. Our focus encompasses the application of the basic principles of physics and engineering to the development of medical devices and technology, with the ultimate aim of producing improvements in the quality of health care.Topics covered include biomechanics, biomaterials, mechanobiology, rehabilitation engineering, biomedical signal processing and medical device development. Medical Engineering & Physics aims to keep both engineers and clinicians abreast of the latest applications of technology to health care.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书