Experimental Testing and Dynamic Simulation of Walking Gait for Transfemoral Prostheses

IF 4.3 Q2 ENGINEERING, BIOMEDICAL
Kuang Nie;Yifei Dong;Xinyu Wu;Sheng Xu;Fei Gao
{"title":"Experimental Testing and Dynamic Simulation of Walking Gait for Transfemoral Prostheses","authors":"Kuang Nie;Yifei Dong;Xinyu Wu;Sheng Xu;Fei Gao","doi":"10.1109/TMRB.2026.3681031","DOIUrl":null,"url":null,"abstract":"As prosthetic leg technology advances, accurate and efficient <italic>methods</i> for testing and evaluating prosthetic components are essential for further development. This work focused on developing a testing platform and performing a simulation model that can streamline prosthetic development and improve testing efficiency. Specifically, a gait simulator consisting of a six-degree-of-freedom (6-DOF) robotic arm integrated with a treadmill was developed to test transfemoral prostheses. The prostheses were fixed to the end of the robotic arm, which was controlled to track the trajectory and posture of the amputee’s residual thigh. In this case, the interactions between the residual limb and the prostheses were considered in this testing, as the motion of the residual limb has a great effect on the motion of the prostheses. Besides, the simulation model of the prostheses was developed to dynamically simulate the gait of the prostheses during walking. The parameters of the prostheses were tested by our platform. The gait of an above-knee amputee during walking was measured, and three prosthetic knees—Ottobock 3R80, Ottobock C-Leg, and a Liangkang Four-bar Linkage were tested here. Results show clear differences between amputee and healthy-subject thigh motion, highlighting the need for amputee-based testing. The gait simulator consistently achieved higher fidelity in reproducing knee kinematics, with average RMSE values of 4.06° vs. 5.64° (C-Leg), 4.70° vs. 8.40° (3R80), and 10.03° vs. 29.0° (Four-bar Linkage), along with higher correlation coefficients in all cases.","PeriodicalId":73318,"journal":{"name":"IEEE transactions on medical robotics and bionics","volume":"8 2","pages":"844-855"},"PeriodicalIF":4.3000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on medical robotics and bionics","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11475188/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/4/6 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

As prosthetic leg technology advances, accurate and efficient methods for testing and evaluating prosthetic components are essential for further development. This work focused on developing a testing platform and performing a simulation model that can streamline prosthetic development and improve testing efficiency. Specifically, a gait simulator consisting of a six-degree-of-freedom (6-DOF) robotic arm integrated with a treadmill was developed to test transfemoral prostheses. The prostheses were fixed to the end of the robotic arm, which was controlled to track the trajectory and posture of the amputee’s residual thigh. In this case, the interactions between the residual limb and the prostheses were considered in this testing, as the motion of the residual limb has a great effect on the motion of the prostheses. Besides, the simulation model of the prostheses was developed to dynamically simulate the gait of the prostheses during walking. The parameters of the prostheses were tested by our platform. The gait of an above-knee amputee during walking was measured, and three prosthetic knees—Ottobock 3R80, Ottobock C-Leg, and a Liangkang Four-bar Linkage were tested here. Results show clear differences between amputee and healthy-subject thigh motion, highlighting the need for amputee-based testing. The gait simulator consistently achieved higher fidelity in reproducing knee kinematics, with average RMSE values of 4.06° vs. 5.64° (C-Leg), 4.70° vs. 8.40° (3R80), and 10.03° vs. 29.0° (Four-bar Linkage), along with higher correlation coefficients in all cases.
经股假体行走步态的实验测试与动态模拟
随着假肢技术的进步,准确、高效的测试和评估假肢部件的方法对假肢的进一步发展至关重要。这项工作的重点是开发一个测试平台,并执行一个仿真模型,可以简化假肢的开发和提高测试效率。具体来说,我们开发了一个由六自由度机械臂和跑步机组成的步态模拟器来测试经股假体。假肢被固定在机器人手臂的末端,机器人手臂被控制来跟踪截肢者剩余大腿的轨迹和姿势。在这种情况下,由于残肢的运动对假体的运动有很大的影响,因此在本次测试中考虑了残肢与假体之间的相互作用。此外,还建立了假肢的仿真模型,对假肢在行走过程中的步态进行动态仿真。利用该平台对修复体的各项参数进行了测试。对膝上截肢者行走时的步态进行了测量,并对三种假肢膝关节——Ottobock 3R80、Ottobock C-Leg和梁康四杆连杆机构进行了测试。结果显示截肢者和健康受试者的大腿运动之间存在明显差异,强调了对截肢者进行测试的必要性。步态模拟器在再现膝关节运动学方面始终保持较高的保真度,平均RMSE值为4.06°vs. 5.64°(C-Leg), 4.70°vs. 8.40°(3R80), 10.03°vs. 29.0°(四杆机构),所有情况下均具有较高的相关系数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.80
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书