Yao Huang;Huifang Liu;Ahmadreza Argha;Branko G. Celler;Andrey V. Savkin;Gongchang Yu;Rong Song;Bin Shi;Steven Weidong Su
{"title":"Practical Multiple Model Switching sEMG Decoders for Motion Intention Description in Rehabilitation Robot Control","authors":"Yao Huang;Huifang Liu;Ahmadreza Argha;Branko G. Celler;Andrey V. Savkin;Gongchang Yu;Rong Song;Bin Shi;Steven Weidong Su","doi":"10.1109/TMRB.2026.3682646","DOIUrl":null,"url":null,"abstract":"Accurate decoding of human motion intention from surface electromyography (sEMG) is crucial for smooth and responsive rehabilitation robot control. This study develops a multiple-model sEMG decoder incorporating a practical bumpless switching strategy that enables seamless transitions among submodels for complex multi-joint movements. The method identifies a minimal common state representation across submodels with different dimensions, ensuring stable and continuous output without abrupt changes during task transitions. Several state-resetting schemes are proposed and experimentally compared in both numerical simulations and real-time human–robot cooperative arm motion tasks. Results demonstrate that the proposed decoder maintains smooth force estimation and robust performance across diverse movement conditions, supporting its applicability to real-time rehabilitation control. Due to safety constraints regarding potential abrupt switching in human-in-the-loop trials, a limited cohort was used; consequently, these findings should be interpreted as exploratory.","PeriodicalId":73318,"journal":{"name":"IEEE transactions on medical robotics and bionics","volume":"8 2","pages":"785-797"},"PeriodicalIF":4.3000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on medical robotics and bionics","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11478496/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/4/9 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Accurate decoding of human motion intention from surface electromyography (sEMG) is crucial for smooth and responsive rehabilitation robot control. This study develops a multiple-model sEMG decoder incorporating a practical bumpless switching strategy that enables seamless transitions among submodels for complex multi-joint movements. The method identifies a minimal common state representation across submodels with different dimensions, ensuring stable and continuous output without abrupt changes during task transitions. Several state-resetting schemes are proposed and experimentally compared in both numerical simulations and real-time human–robot cooperative arm motion tasks. Results demonstrate that the proposed decoder maintains smooth force estimation and robust performance across diverse movement conditions, supporting its applicability to real-time rehabilitation control. Due to safety constraints regarding potential abrupt switching in human-in-the-loop trials, a limited cohort was used; consequently, these findings should be interpreted as exploratory.