Chi-Jen Wen;Tee Lin;Omid Ali Zargar;Chi-Huan Hsieh;Shih-Cheng Hu;Yang-Cheng Shih;Graham Leggett
{"title":"Effectiveness of a High-Velocity-Type Laminar Air Curtain Device for Moisture Isolation Under EFEM Airflow Deflection During FOUP Door Opening","authors":"Chi-Jen Wen;Tee Lin;Omid Ali Zargar;Chi-Huan Hsieh;Shih-Cheng Hu;Yang-Cheng Shih;Graham Leggett","doi":"10.1109/TSM.2026.3665224","DOIUrl":null,"url":null,"abstract":"As semiconductor manufacturing advances toward the 3 nm node and beyond, wafer sensitivity to particulate and moisture contamination becomes increasingly critical. During front opening unified pod (FOUP) door opening, airflow disturbances and deflection from the equipment front-end module (EFEM) can lead to the intrusion of external moisture and airborne molecular contaminants (AMC), potentially degrading wafer surface integrity and process yield. To address this, a high-velocity-type laminar air curtain device (HV-LAC) was developed using a low-pressure-drop PTFE filter combined with an airflow deflector and perforated plate. This design overcomes deformation and particle-shedding issues seen in conventional ultra-high molecular weight polyethylene (UPE) panels under high flow rates, while improving flow uniformity and barrier stability. The HV-LAC achieved a maximum outlet velocity of 0.54 m/s, maintained velocity non-uniformity around 10% across all flow conditions, and met ISO Class 1 cleanliness. Performance evaluation was conducted under combinations of EFEM background velocities (0.3, 0.4, 0.5 m/s), airflow deflection angles (0°, 15°, 30°), and curtain velocities (0.35, 0.41, 0.54 m/s), with FOUP purge flow at 130 LPM. Experimental results confirmed that the HV-LAC effectively suppressed moisture intrusion, with FOUP internal relative humidity (RH) maintained below 5% in all conditions. The best isolation was observed when curtain velocity matched EFEM airflow, demonstrating that velocity matching is critical to maintaining barrier integrity. This study offers a quantitative design reference for enhancing FOUP micro-environmental control in advanced semiconductor processes.","PeriodicalId":451,"journal":{"name":"IEEE Transactions on Semiconductor Manufacturing","volume":"39 2","pages":"310-319"},"PeriodicalIF":2.5000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Semiconductor Manufacturing","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/11397396/","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/2/16 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0
Abstract
As semiconductor manufacturing advances toward the 3 nm node and beyond, wafer sensitivity to particulate and moisture contamination becomes increasingly critical. During front opening unified pod (FOUP) door opening, airflow disturbances and deflection from the equipment front-end module (EFEM) can lead to the intrusion of external moisture and airborne molecular contaminants (AMC), potentially degrading wafer surface integrity and process yield. To address this, a high-velocity-type laminar air curtain device (HV-LAC) was developed using a low-pressure-drop PTFE filter combined with an airflow deflector and perforated plate. This design overcomes deformation and particle-shedding issues seen in conventional ultra-high molecular weight polyethylene (UPE) panels under high flow rates, while improving flow uniformity and barrier stability. The HV-LAC achieved a maximum outlet velocity of 0.54 m/s, maintained velocity non-uniformity around 10% across all flow conditions, and met ISO Class 1 cleanliness. Performance evaluation was conducted under combinations of EFEM background velocities (0.3, 0.4, 0.5 m/s), airflow deflection angles (0°, 15°, 30°), and curtain velocities (0.35, 0.41, 0.54 m/s), with FOUP purge flow at 130 LPM. Experimental results confirmed that the HV-LAC effectively suppressed moisture intrusion, with FOUP internal relative humidity (RH) maintained below 5% in all conditions. The best isolation was observed when curtain velocity matched EFEM airflow, demonstrating that velocity matching is critical to maintaining barrier integrity. This study offers a quantitative design reference for enhancing FOUP micro-environmental control in advanced semiconductor processes.
期刊介绍:
The IEEE Transactions on Semiconductor Manufacturing addresses the challenging problems of manufacturing complex microelectronic components, especially very large scale integrated circuits (VLSI). Manufacturing these products requires precision micropatterning, precise control of materials properties, ultraclean work environments, and complex interactions of chemical, physical, electrical and mechanical processes.