A Dual-Arm Robotic System With Virtual Fixture-Guided Light Tracking for Fundus Surgery

IF 4.3 Q2 ENGINEERING, BIOMEDICAL
Zhaodong Wang;Chenhan Guang;Yu Zheng;Hao Li;Yang Yang;Chuang Lin
{"title":"A Dual-Arm Robotic System With Virtual Fixture-Guided Light Tracking for Fundus Surgery","authors":"Zhaodong Wang;Chenhan Guang;Yu Zheng;Hao Li;Yang Yang;Chuang Lin","doi":"10.1109/TMRB.2026.3680967","DOIUrl":null,"url":null,"abstract":"Retinal surgery demands submillimeter precision in constrained intraocular spaces, with subretinal injections requiring accurate bimanual coordination between surgical tools and illumination devices. This paper presents the Dual-Arm Robotic System for Subretinal Injection (DASSI), featuring a motion-decoupled Remote Center of Motion (RCM) mechanism and an initial placement strategy to optimize dual-arm workspace overlap. An Automatic Light Pipe Tracking algorithm with Guided Virtual Fixtures (ATLP-GVF) is developed to eliminate redundant light pipe motion when illumination needs are met. Integrated with its hardware design (motion-decoupled RCM mechanism) and ATLP-GVF, DASSI achieves precise performance: orientation tracking error (<inline-formula> <tex-math>$0.65^{\\circ } \\pm ~0.28^{\\circ }$ </tex-math></inline-formula>), depth error (1.86 mm <inline-formula> <tex-math>$\\pm ~0.93$ </tex-math></inline-formula> mm), and stable illumination (tracking offset ratio 26% <inline-formula> <tex-math>$\\pm ~14$ </tex-math></inline-formula>%). Notably, in the ex-vivo experiment, ATLP-GVF reduces light pipe movement duration to less than 10% of that with continuous tracking methods, representing a reduction of more than 90%. DASSI demonstrates potential to address bimanual coordination challenges in retinal microsurgery, offering a precise platform for complex procedures such as subretinal gene-therapy delivery.","PeriodicalId":73318,"journal":{"name":"IEEE transactions on medical robotics and bionics","volume":"8 2","pages":"642-653"},"PeriodicalIF":4.3000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on medical robotics and bionics","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11475147/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/4/6 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Retinal surgery demands submillimeter precision in constrained intraocular spaces, with subretinal injections requiring accurate bimanual coordination between surgical tools and illumination devices. This paper presents the Dual-Arm Robotic System for Subretinal Injection (DASSI), featuring a motion-decoupled Remote Center of Motion (RCM) mechanism and an initial placement strategy to optimize dual-arm workspace overlap. An Automatic Light Pipe Tracking algorithm with Guided Virtual Fixtures (ATLP-GVF) is developed to eliminate redundant light pipe motion when illumination needs are met. Integrated with its hardware design (motion-decoupled RCM mechanism) and ATLP-GVF, DASSI achieves precise performance: orientation tracking error ( $0.65^{\circ } \pm ~0.28^{\circ }$ ), depth error (1.86 mm $\pm ~0.93$ mm), and stable illumination (tracking offset ratio 26% $\pm ~14$ %). Notably, in the ex-vivo experiment, ATLP-GVF reduces light pipe movement duration to less than 10% of that with continuous tracking methods, representing a reduction of more than 90%. DASSI demonstrates potential to address bimanual coordination challenges in retinal microsurgery, offering a precise platform for complex procedures such as subretinal gene-therapy delivery.
用于眼底手术的虚拟夹具引导光跟踪双臂机器人系统
视网膜手术需要在受限的眼内空间内达到亚毫米级的精度,视网膜下注射需要在手术工具和照明设备之间进行精确的双手协调。本文提出了一种用于视网膜下注射的双臂机器人系统(DASSI),该系统具有运动解耦的远程运动中心(RCM)机构和优化双臂工作空间重叠的初始放置策略。为了在满足照明需求的情况下消除光管的冗余运动,提出了一种带引导虚拟夹具的光管自动跟踪算法。结合其硬件设计(运动解耦RCM机制)和ATLP-GVF, DASSI实现了精确的性能:方向跟踪误差($0.65^{\circ} \pm ~0.28^{\circ}$)、深度误差($ 1.86 mm $\pm ~0.93$ mm)和稳定的照明(跟踪偏移比26% $\pm ~14$ %)。值得注意的是,在离体实验中,ATLP-GVF将光管运动时间减少到连续跟踪方法的10%以下,减少了90%以上。DASSI展示了解决视网膜显微手术中双手协调挑战的潜力,为视网膜下基因治疗递送等复杂程序提供了精确的平台。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.80
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书