Zhaodong Wang;Chenhan Guang;Yu Zheng;Hao Li;Yang Yang;Chuang Lin
{"title":"A Dual-Arm Robotic System With Virtual Fixture-Guided Light Tracking for Fundus Surgery","authors":"Zhaodong Wang;Chenhan Guang;Yu Zheng;Hao Li;Yang Yang;Chuang Lin","doi":"10.1109/TMRB.2026.3680967","DOIUrl":null,"url":null,"abstract":"Retinal surgery demands submillimeter precision in constrained intraocular spaces, with subretinal injections requiring accurate bimanual coordination between surgical tools and illumination devices. This paper presents the Dual-Arm Robotic System for Subretinal Injection (DASSI), featuring a motion-decoupled Remote Center of Motion (RCM) mechanism and an initial placement strategy to optimize dual-arm workspace overlap. An Automatic Light Pipe Tracking algorithm with Guided Virtual Fixtures (ATLP-GVF) is developed to eliminate redundant light pipe motion when illumination needs are met. Integrated with its hardware design (motion-decoupled RCM mechanism) and ATLP-GVF, DASSI achieves precise performance: orientation tracking error (<inline-formula> <tex-math>$0.65^{\\circ } \\pm ~0.28^{\\circ }$ </tex-math></inline-formula>), depth error (1.86 mm <inline-formula> <tex-math>$\\pm ~0.93$ </tex-math></inline-formula> mm), and stable illumination (tracking offset ratio 26% <inline-formula> <tex-math>$\\pm ~14$ </tex-math></inline-formula>%). Notably, in the ex-vivo experiment, ATLP-GVF reduces light pipe movement duration to less than 10% of that with continuous tracking methods, representing a reduction of more than 90%. DASSI demonstrates potential to address bimanual coordination challenges in retinal microsurgery, offering a precise platform for complex procedures such as subretinal gene-therapy delivery.","PeriodicalId":73318,"journal":{"name":"IEEE transactions on medical robotics and bionics","volume":"8 2","pages":"642-653"},"PeriodicalIF":4.3000,"publicationDate":"2026-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on medical robotics and bionics","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11475147/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/4/6 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Retinal surgery demands submillimeter precision in constrained intraocular spaces, with subretinal injections requiring accurate bimanual coordination between surgical tools and illumination devices. This paper presents the Dual-Arm Robotic System for Subretinal Injection (DASSI), featuring a motion-decoupled Remote Center of Motion (RCM) mechanism and an initial placement strategy to optimize dual-arm workspace overlap. An Automatic Light Pipe Tracking algorithm with Guided Virtual Fixtures (ATLP-GVF) is developed to eliminate redundant light pipe motion when illumination needs are met. Integrated with its hardware design (motion-decoupled RCM mechanism) and ATLP-GVF, DASSI achieves precise performance: orientation tracking error ($0.65^{\circ } \pm ~0.28^{\circ }$ ), depth error (1.86 mm $\pm ~0.93$ mm), and stable illumination (tracking offset ratio 26% $\pm ~14$ %). Notably, in the ex-vivo experiment, ATLP-GVF reduces light pipe movement duration to less than 10% of that with continuous tracking methods, representing a reduction of more than 90%. DASSI demonstrates potential to address bimanual coordination challenges in retinal microsurgery, offering a precise platform for complex procedures such as subretinal gene-therapy delivery.