Membrane Sensorization for Acoustic Coupling Optimization in a Robotic HIFU Platform

IF 4.3 Q2 ENGINEERING, BIOMEDICAL
Silvia Buratti;Daniele Moglia;Francesca Parrotta;Selene Tognarelli;Andrea Cafarelli;Mariangela Filosa;Calogero Maria Oddo;Arianna Menciassi
{"title":"Membrane Sensorization for Acoustic Coupling Optimization in a Robotic HIFU Platform","authors":"Silvia Buratti;Daniele Moglia;Francesca Parrotta;Selene Tognarelli;Andrea Cafarelli;Mariangela Filosa;Calogero Maria Oddo;Arianna Menciassi","doi":"10.1109/TMRB.2025.3617983","DOIUrl":null,"url":null,"abstract":"High-Intensity Focused Ultrasound (HIFU) surgery is a non-invasive therapeutic technology that allows for precise energy delivery for ablating tumors and treating neurological disorders. Maintaining optimal acoustic coupling between the HIFU transducer and the patient’s skin is essential for treatment efficiency, but the coupling is often compromised by anatomical constraints, patient movements and wrong positioning. Monitoring pressure throughout the membrane would enable acoustic coupling optimization. In this framework, the objective of this study is to develop and validate a novel, acoustically transparent sensorized membrane as a foundational component for acoustic coupling optimization. Various sensors were tested acoustically for ultrasound transparency, with Fiber Bragg Grating (FBG) sensors demonstrating minimal wave reflection. A custom silicone membrane (<inline-formula> <tex-math>$700~\\mu $ </tex-math></inline-formula>m in thickness) was fabricated and acoustically and mechanically characterized. Ex vivo HIFU sonication validated the transparency of sensorized membrane, showing no statistically significant impact on lesion formation. Finally, the actual capability of the FBGs optical fiber to sense the contact across all the membrane was validated through indentation tests. By successfully demonstrating the feasibility and performance of this core component, this work establishes a foundation for real-time acoustic coupling optimization systems, paving the way for enhanced HIFU treatment safety and efficacy.","PeriodicalId":73318,"journal":{"name":"IEEE transactions on medical robotics and bionics","volume":"8 1","pages":"30-40"},"PeriodicalIF":4.3000,"publicationDate":"2026-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=11193694","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on medical robotics and bionics","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/11193694/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/10/6 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

High-Intensity Focused Ultrasound (HIFU) surgery is a non-invasive therapeutic technology that allows for precise energy delivery for ablating tumors and treating neurological disorders. Maintaining optimal acoustic coupling between the HIFU transducer and the patient’s skin is essential for treatment efficiency, but the coupling is often compromised by anatomical constraints, patient movements and wrong positioning. Monitoring pressure throughout the membrane would enable acoustic coupling optimization. In this framework, the objective of this study is to develop and validate a novel, acoustically transparent sensorized membrane as a foundational component for acoustic coupling optimization. Various sensors were tested acoustically for ultrasound transparency, with Fiber Bragg Grating (FBG) sensors demonstrating minimal wave reflection. A custom silicone membrane ( $700~\mu $ m in thickness) was fabricated and acoustically and mechanically characterized. Ex vivo HIFU sonication validated the transparency of sensorized membrane, showing no statistically significant impact on lesion formation. Finally, the actual capability of the FBGs optical fiber to sense the contact across all the membrane was validated through indentation tests. By successfully demonstrating the feasibility and performance of this core component, this work establishes a foundation for real-time acoustic coupling optimization systems, paving the way for enhanced HIFU treatment safety and efficacy.
基于膜传感器的机器人HIFU平台声耦合优化
高强度聚焦超声(HIFU)手术是一种非侵入性的治疗技术,允许精确的能量输送用于消融肿瘤和治疗神经系统疾病。维持HIFU换能器与患者皮肤之间的最佳声学耦合对于提高治疗效率至关重要,但这种耦合常常受到解剖学限制、患者运动和错误定位的影响。监测整个膜的压力可以优化声耦合。在这个框架下,本研究的目的是开发和验证一种新型的、声透明的传感膜,作为声耦合优化的基础组件。对各种传感器的超声透明度进行了声学测试,光纤布拉格光栅(FBG)传感器显示出最小的波反射。制作了厚度为700~ $ μ $ m的定制硅胶膜,并对其进行了声学和机械表征。体外HIFU超声验证了传感膜的透明度,对病变形成无统计学意义的影响。最后,通过压痕测试验证了光纤光栅光纤感知所有薄膜接触的实际能力。通过成功展示该核心组件的可行性和性能,本工作为实时声耦合优化系统奠定了基础,为提高HIFU治疗的安全性和有效性铺平了道路。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.80
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书