Development and experimental characterization of a cadaveric stance simulator for residual limb biomechanics.

IF 2.4 4区 医学 Q3 ENGINEERING, BIOMEDICAL
David V Herlihy, John M Chomack, David N Paglia, Charlene Wetterstrand, J Patrick O'Connor, Susan E D'Andrea, Jason T Maikos
{"title":"Development and experimental characterization of a cadaveric stance simulator for residual limb biomechanics.","authors":"David V Herlihy, John M Chomack, David N Paglia, Charlene Wetterstrand, J Patrick O'Connor, Susan E D'Andrea, Jason T Maikos","doi":"10.1088/1873-4030/ae8544","DOIUrl":null,"url":null,"abstract":"<p><p>Understanding the biomechanical interaction between residual limbs and prosthetic sockets is essential for optimizing prosthesis design and minimizing tissue injury. Existing cadaveric stance simulators have not been specifically designed to examine socket-residual limb biomechanics. This study designed, constructed, and evaluated a cadaveric stance simulator capable of applying physiologically representative compressive forces through residual limbs. The long-term objective is to utilize dynamic stereo x-ray (DSX) to quantify 3D skin strain at the socket-residual limb interface, for which this simulator serves as a critical foundational step. The simulator combined passive spring compression with active stepper motor control to generate characteristic double-peaked vertical ground reaction force (vGRF) profiles of stance phase. Primary validation was performed under idealized conditions using a rigid prosthesis configuration, with cadaveric testing as a secondary feasibility assessment on two residual limbs with direct force plate measurement. Validation metrics included peak vGRF, peak-to-valley (P2V) ratio, first-to-second peak symmetry (P2P), and loading and unloading rates, with target parameters derived from five participants with transtibial limb loss. Non-parametric analyses compared simulator outputs with control data. Spring-based force estimates were validated against force plate measurements using root mean square (RMS) error and Bland-Altman analyses. Idealized trials showed no significant differences across validation metrics, indicating the simulator closely matched selected physiological loading metrics. Exploratory cadaveric comparisons demonstrated lower peak vGRF, P2V ratio, and unloading rates relative to control participants, attributable to intentional force reductions to preserve tissue integrity. Spring-based force estimates demonstrated preliminary agreement with force plate measurements, supported by RMS error and Bland-Altman analysis. The stance simulator provided a repeatable, adaptable platform for physiologically representative residual limb loading. Its compatibility with DSX imaging establishes a foundation for quantifying 3D skin strain at the socket-residual limb interface, supporting improved socket design and outcomes for individuals with lower limb loss.</p>","PeriodicalId":49836,"journal":{"name":"Medical Engineering & Physics","volume":" ","pages":""},"PeriodicalIF":2.4000,"publicationDate":"2026-07-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Engineering & Physics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1873-4030/ae8544","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Understanding the biomechanical interaction between residual limbs and prosthetic sockets is essential for optimizing prosthesis design and minimizing tissue injury. Existing cadaveric stance simulators have not been specifically designed to examine socket-residual limb biomechanics. This study designed, constructed, and evaluated a cadaveric stance simulator capable of applying physiologically representative compressive forces through residual limbs. The long-term objective is to utilize dynamic stereo x-ray (DSX) to quantify 3D skin strain at the socket-residual limb interface, for which this simulator serves as a critical foundational step. The simulator combined passive spring compression with active stepper motor control to generate characteristic double-peaked vertical ground reaction force (vGRF) profiles of stance phase. Primary validation was performed under idealized conditions using a rigid prosthesis configuration, with cadaveric testing as a secondary feasibility assessment on two residual limbs with direct force plate measurement. Validation metrics included peak vGRF, peak-to-valley (P2V) ratio, first-to-second peak symmetry (P2P), and loading and unloading rates, with target parameters derived from five participants with transtibial limb loss. Non-parametric analyses compared simulator outputs with control data. Spring-based force estimates were validated against force plate measurements using root mean square (RMS) error and Bland-Altman analyses. Idealized trials showed no significant differences across validation metrics, indicating the simulator closely matched selected physiological loading metrics. Exploratory cadaveric comparisons demonstrated lower peak vGRF, P2V ratio, and unloading rates relative to control participants, attributable to intentional force reductions to preserve tissue integrity. Spring-based force estimates demonstrated preliminary agreement with force plate measurements, supported by RMS error and Bland-Altman analysis. The stance simulator provided a repeatable, adaptable platform for physiologically representative residual limb loading. Its compatibility with DSX imaging establishes a foundation for quantifying 3D skin strain at the socket-residual limb interface, supporting improved socket design and outcomes for individuals with lower limb loss.

残肢生物力学人体姿态模拟器的研制与实验表征。
背景:了解残肢与义肢窝之间的生物力学相互作用对于优化义肢设计和减少组织损伤至关重要。现有的尸体姿态模拟器还没有专门设计用于检查关节-残肢生物力学。本研究设计、构建并评估了一种能够对残肢施加具有生理代表性的压缩力的尸体姿态模拟器。长期目标是利用动态立体x射线(DSX)来量化插座-残肢界面的三维皮肤应变,该模拟器是关键的基础步骤。方法:将被动弹簧压缩与主动步进电机控制相结合,生成姿态相位特征双峰垂直地面反力(vGRF)曲线。在理想条件下使用刚性假体结构进行初步验证,并通过直接力板测量对两个残肢进行尸体试验作为二次可行性评估。验证指标包括峰值vGRF、峰谷比(P2V)、第一到第二峰对称(P2P)和加载和卸载速率,目标参数来自5名胫骨肢体丧失的参与者。非参数分析将模拟器输出与对照数据进行比较(α = 0.05)。基于弹簧压缩的力估计通过均方根误差分析与力板测量结果进行验证。结果:理想化的试验再现了生理vGRF剖面,在验证指标之间没有显著差异,证实了准确的姿态相位加载再现是主要结果。探索性尸体比较显示,与对照组相比,vGRF峰值、P2V比和卸载率较低,这可归因于有意减少力以保持组织完整性。基于弹簧的力估计与力板测量值非常接近。结论:该姿态模拟器为具有生理代表性的残肢加载提供了一个可重复、适应性强的平台。它与DSX成像的兼容性为量化支架-残肢界面的3D皮肤应变奠定了基础,支持改进的支架设计和下肢丧失患者的预后。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical Engineering & Physics
Medical Engineering & Physics 工程技术-工程:生物医学
CiteScore
4.30
自引率
4.50%
发文量
172
审稿时长
3.0 months
期刊介绍: Medical Engineering & Physics provides a forum for the publication of the latest developments in biomedical engineering, and reflects the essential multidisciplinary nature of the subject. The journal publishes in-depth critical reviews, scientific papers and technical notes. Our focus encompasses the application of the basic principles of physics and engineering to the development of medical devices and technology, with the ultimate aim of producing improvements in the quality of health care.Topics covered include biomechanics, biomaterials, mechanobiology, rehabilitation engineering, biomedical signal processing and medical device development. Medical Engineering & Physics aims to keep both engineers and clinicians abreast of the latest applications of technology to health care.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书