{"title":"Development of a terbium-based coordination polymer nanoprobe for determination of clonazepam in exhaled breath condensate.","authors":"Zahra Najafzadeh, Tahir Suleymanov, Maryam Khoubnasabjafari, Vahid Jouyban-Gharamaleki, Jalal Hanaee, Elaheh Rahimpour, Abolghasem Jouyban","doi":"10.34172/bi.33423","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Clonazepam is a long-acting benzodiazepine utilized for conditions such as seizures, panic disorder, and other neurological/psychiatric disorders. It functions by increasing GABA effects, which leads to reduced neural activity. Careful dosage titration and monitoring are necessary due to potential side effects, including drowsiness, impaired motor coordination, memory loss, and dependence.</p><p><strong>Methods: </strong>In this work, an optical probe based on a terbium (Tb) coordination polymer was developed for the quantification of clonazepam in the exhaled breath condensate (EBC). The principle of the probe was based on the interaction of clonazepam with pyridine-2,6-dicarboxylic acid -Tb coordination polymer nanoparticles, which dynamically quenches the Tb³⁺ luminescence through a collisional mechanism, as confirmed by the linear Stern-Volmer plot and the increased quenching efficiency at higher temperatures. As the increase in response intensity is proportional to clonazepam concentration, a method was offered for its determination in EBC samples.</p><p><strong>Results: </strong>This method presented a linear relationship with clonazepam concentration in the range of 0.001-1.5 µg.mL<sup>-1</sup> with a limit of detection of 0.0002 µg.mL<sup>-1</sup> and the intra-day and inter-day relative standard deviation of 1.8%, and 2.7%, respectively. The validated method was used for clonazepam analysis in patients receiving this medication. The recovery values, ranged from 90% to 104%, served as an indicator of the method's accuracy, and confirmed that the measured signal was attributable specifically to clonazepam with high reliability.</p><p><strong>Conclusion: </strong>By being faster, simpler, and cost-effective than traditional techniques, this method presented a valuable tool for therapeutic drug monitoring.</p>","PeriodicalId":48614,"journal":{"name":"Bioimpacts","volume":"16 ","pages":"33423"},"PeriodicalIF":2.5000,"publicationDate":"2026-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13310246/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioimpacts","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.34172/bi.33423","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Clonazepam is a long-acting benzodiazepine utilized for conditions such as seizures, panic disorder, and other neurological/psychiatric disorders. It functions by increasing GABA effects, which leads to reduced neural activity. Careful dosage titration and monitoring are necessary due to potential side effects, including drowsiness, impaired motor coordination, memory loss, and dependence.
Methods: In this work, an optical probe based on a terbium (Tb) coordination polymer was developed for the quantification of clonazepam in the exhaled breath condensate (EBC). The principle of the probe was based on the interaction of clonazepam with pyridine-2,6-dicarboxylic acid -Tb coordination polymer nanoparticles, which dynamically quenches the Tb³⁺ luminescence through a collisional mechanism, as confirmed by the linear Stern-Volmer plot and the increased quenching efficiency at higher temperatures. As the increase in response intensity is proportional to clonazepam concentration, a method was offered for its determination in EBC samples.
Results: This method presented a linear relationship with clonazepam concentration in the range of 0.001-1.5 µg.mL-1 with a limit of detection of 0.0002 µg.mL-1 and the intra-day and inter-day relative standard deviation of 1.8%, and 2.7%, respectively. The validated method was used for clonazepam analysis in patients receiving this medication. The recovery values, ranged from 90% to 104%, served as an indicator of the method's accuracy, and confirmed that the measured signal was attributable specifically to clonazepam with high reliability.
Conclusion: By being faster, simpler, and cost-effective than traditional techniques, this method presented a valuable tool for therapeutic drug monitoring.
BioimpactsPharmacology, Toxicology and Pharmaceutics-Pharmaceutical Science
CiteScore
4.80
自引率
7.70%
发文量
36
审稿时长
5 weeks
期刊介绍:
BioImpacts (BI) is a peer-reviewed multidisciplinary international journal, covering original research articles, reviews, commentaries, hypotheses, methodologies, and visions/reflections dealing with all aspects of biological and biomedical researches at molecular, cellular, functional and translational dimensions.