Improvement of dynamic pupillary function after cataract surgery in eyes with pseudoexfoliation syndrome: a six-month longitudinal pupillometry study.

IF 2 4区 医学 Q2 OPHTHALMOLOGY
Goksu Alacamlı, Omer Ozer, Murat Kasıkcı
{"title":"Improvement of dynamic pupillary function after cataract surgery in eyes with pseudoexfoliation syndrome: a six-month longitudinal pupillometry study.","authors":"Goksu Alacamlı, Omer Ozer, Murat Kasıkcı","doi":"10.1007/s10633-026-10121-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Impaired pupillary dynamics are a well-recognized feature of pseudoexfoliation syndrome (PXF), yet little is known about how cataract surgery influences postoperative iris function in these eyes. This study aimed to determine the longitudinal effects of cataract surgery on static pupil diameters and dilation velocity in eyes with pseudoexfoliation syndrome compared with age-matched controls.</p><p><strong>Methods: </strong>This longitudinal study included 166 eyes of 166 patients undergoing cataract surgery, comprising 91 eyes with pseudoexfoliation syndrome and 75 control eyes without pseudoexfoliation. Pupillary parameters were measured preoperatively and at six months postoperatively using automated pupillometry. Static pupil diameters were assessed under scotopic (0.04 lx), mesopic (4 lx), and photopic (40 lx) illumination conditions. Dynamic pupillary function was evaluated by measuring dilation velocity (DVel, mm/s) following a standardized light stimulus. Postoperative changes (Δ) were calculated as the difference between preoperative and postoperative measurements.</p><p><strong>Results: </strong>Static pupil diameters remained stable in the PXF group across all illumination conditions (p > 0.05). In contrast, the control group demonstrated a significant reduction in scotopic pupil diameter after surgery (p = 0.008), while mesopic and photopic diameters remained unchanged. The most notable finding was observed in pupillary kinetics: dilation velocity significantly increased in the PXF group from 0.13 ± 0.04 mm/s to 0.17 ± 0.05 mm/s (p < 0.001), whereas no significant change was detected in the control group. Between-group comparison showed a significantly greater improvement in dilation velocity in PXF eyes (p < 0.001). Cataract morphology was not associated with postoperative pupillary changes.</p><p><strong>Conclusion: </strong>These findings suggest that cataract surgery may be associated with measurable changes in dynamic pupillary behavior in PXF eyes, particularly in dilation velocity, while static pupil diameter remains largely unchanged.</p>","PeriodicalId":11207,"journal":{"name":"Documenta Ophthalmologica","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2026-06-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Documenta Ophthalmologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10633-026-10121-x","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Impaired pupillary dynamics are a well-recognized feature of pseudoexfoliation syndrome (PXF), yet little is known about how cataract surgery influences postoperative iris function in these eyes. This study aimed to determine the longitudinal effects of cataract surgery on static pupil diameters and dilation velocity in eyes with pseudoexfoliation syndrome compared with age-matched controls.

Methods: This longitudinal study included 166 eyes of 166 patients undergoing cataract surgery, comprising 91 eyes with pseudoexfoliation syndrome and 75 control eyes without pseudoexfoliation. Pupillary parameters were measured preoperatively and at six months postoperatively using automated pupillometry. Static pupil diameters were assessed under scotopic (0.04 lx), mesopic (4 lx), and photopic (40 lx) illumination conditions. Dynamic pupillary function was evaluated by measuring dilation velocity (DVel, mm/s) following a standardized light stimulus. Postoperative changes (Δ) were calculated as the difference between preoperative and postoperative measurements.

Results: Static pupil diameters remained stable in the PXF group across all illumination conditions (p > 0.05). In contrast, the control group demonstrated a significant reduction in scotopic pupil diameter after surgery (p = 0.008), while mesopic and photopic diameters remained unchanged. The most notable finding was observed in pupillary kinetics: dilation velocity significantly increased in the PXF group from 0.13 ± 0.04 mm/s to 0.17 ± 0.05 mm/s (p < 0.001), whereas no significant change was detected in the control group. Between-group comparison showed a significantly greater improvement in dilation velocity in PXF eyes (p < 0.001). Cataract morphology was not associated with postoperative pupillary changes.

Conclusion: These findings suggest that cataract surgery may be associated with measurable changes in dynamic pupillary behavior in PXF eyes, particularly in dilation velocity, while static pupil diameter remains largely unchanged.

假性角膜脱落综合征白内障术后动态瞳孔功能的改善:一项为期六个月的纵向瞳孔测量研究。
目的:瞳孔动力学受损是假性脱落综合征(PXF)的一个众所周知的特征,但对于白内障手术如何影响这些眼睛的术后虹膜功能知之甚少。本研究旨在确定白内障手术对假脱落综合征患者静态瞳孔直径和扩张速度的纵向影响,并与年龄匹配的对照组进行比较。方法:对166例白内障手术患者166只眼进行纵向研究,其中91只眼存在假性角膜脱落综合征,75只眼没有假性角膜脱落。术前和术后6个月用自动瞳孔测量仪测量瞳孔参数。在暗聚光(0.04 lx)、中聚光(4 lx)和光聚光(40 lx)照明条件下评估静态瞳孔直径。通过测量标准化光刺激后的扩张速度(DVel, mm/s)来评估动态瞳孔功能。术后变化(Δ)计算为术前和术后测量值的差异。结果:在所有光照条件下,PXF组静态瞳孔直径保持稳定(p > 0.05)。相比之下,对照组术后暗视瞳孔直径明显减小(p = 0.008),而中视和光视直径保持不变。最显著的发现是瞳孔动力学:PXF组的瞳孔扩张速度从0.13±0.04 mm/s显著增加到0.17±0.05 mm/s (p)。结论:这些发现表明白内障手术可能与PXF眼瞳孔动态行为的可测量变化有关,尤其是扩张速度,而静态瞳孔直径基本保持不变。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Documenta Ophthalmologica
Documenta Ophthalmologica 医学-眼科学
CiteScore
3.50
自引率
21.40%
发文量
46
审稿时长
>12 weeks
期刊介绍: Documenta Ophthalmologica is an official publication of the International Society for Clinical Electrophysiology of Vision. The purpose of the journal is to promote the understanding and application of clinical electrophysiology of vision. Documenta Ophthalmologica will publish reviews, research articles, technical notes, brief reports and case studies which inform the readers about basic and clinical sciences related to visual electrodiagnosis and means to improve diagnosis and clinical management of patients using visual electrophysiology. Studies may involve animals or humans. In either case appropriate care must be taken to follow the Declaration of Helsinki for human subject or appropriate humane standards of animal care (e.g., the ARVO standards on Animal Care and Use).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书