A comparative evaluation of analytical methods for the detection of titanium dioxide in chewing gum.

IF 2.2
Ivana Bianchi, Robert Brogioli, Hind El-Hadri, Otmar Geiss, Hans-Ulrich Scheele, Silvio Arpagaus, Josefa Barrero
{"title":"A comparative evaluation of analytical methods for the detection of titanium dioxide in chewing gum.","authors":"Ivana Bianchi, Robert Brogioli, Hind El-Hadri, Otmar Geiss, Hans-Ulrich Scheele, Silvio Arpagaus, Josefa Barrero","doi":"10.1080/19440049.2026.2681204","DOIUrl":null,"url":null,"abstract":"<p><p>The EU ban on the use of titanium dioxide (TiO<sub>2</sub>) as a food additive (E 171) has highlighted the need for harmonised and robust analytical methods to ensure uniform regulatory compliance and safeguard consumer health. This study compares three instrumental methods, namely portable X-ray fluorescence (pXRF), macro-Raman spectroscopy (applied to both intact and digested samples), and inductively coupled plasma mass spectrometry (ICP-MS), for detecting and quantifying titanium (Ti) or titanium dioxide (TiO<sub>2</sub>) in 35 chewing-gum samples of different shapes and colours, outlining their specific advantages and limitations. The results show that two items contained E 171, in agreement with the label declarations, and demonstrate, for the specific case of chewing gums where TiO<sub>2</sub> is added to the coating, high concordance among the four applied analytical approaches. pXRF and Macro-Raman spectroscopy, when applied to intact samples, enable safe and rapid screening on the presence of Ti and TiO<sub>2</sub> respectively in the sample's surface while a mild acidic digestion step followed by Raman analysis provides a confirmatory step for complex or interfered spectra. ICP-MS, despite relying on careful and laborious sample preparation, allows accurate quantitative results of Ti to estimate TiO<sub>2</sub>. Thanks to its sensitivity and elemental specificity, low Ti levels can be determined which however may not necessarily indicate intentional E 171 addition.</p>","PeriodicalId":520628,"journal":{"name":"Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment","volume":" ","pages":"1063-1070"},"PeriodicalIF":2.2000,"publicationDate":"2026-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/19440049.2026.2681204","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/6/5 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The EU ban on the use of titanium dioxide (TiO2) as a food additive (E 171) has highlighted the need for harmonised and robust analytical methods to ensure uniform regulatory compliance and safeguard consumer health. This study compares three instrumental methods, namely portable X-ray fluorescence (pXRF), macro-Raman spectroscopy (applied to both intact and digested samples), and inductively coupled plasma mass spectrometry (ICP-MS), for detecting and quantifying titanium (Ti) or titanium dioxide (TiO2) in 35 chewing-gum samples of different shapes and colours, outlining their specific advantages and limitations. The results show that two items contained E 171, in agreement with the label declarations, and demonstrate, for the specific case of chewing gums where TiO2 is added to the coating, high concordance among the four applied analytical approaches. pXRF and Macro-Raman spectroscopy, when applied to intact samples, enable safe and rapid screening on the presence of Ti and TiO2 respectively in the sample's surface while a mild acidic digestion step followed by Raman analysis provides a confirmatory step for complex or interfered spectra. ICP-MS, despite relying on careful and laborious sample preparation, allows accurate quantitative results of Ti to estimate TiO2. Thanks to its sensitivity and elemental specificity, low Ti levels can be determined which however may not necessarily indicate intentional E 171 addition.

口香糖中二氧化钛检测方法的比较评价。
欧盟禁止使用二氧化钛(TiO2)作为食品添加剂(e171),强调需要统一和强大的分析方法,以确保统一的法规遵从性和保护消费者健康。本研究比较了便携式x射线荧光(pXRF)、宏观拉曼光谱(适用于完整样品和消化样品)和电感耦合等离子体质谱(ICP-MS)三种仪器方法对35种不同形状和颜色口香糖样品中钛(Ti)或二氧化钛(TiO2)的检测和定量,并概述了它们的具体优点和局限性。结果表明,两个项目中含有e171,与标签声明一致,并证明,在口香糖中添加TiO2的具体情况下,四种应用的分析方法之间的一致性很高。pXRF和宏观拉曼光谱,当应用于完整样品时,可以安全快速地筛选样品表面Ti和TiO2的存在,而温和的酸性消化步骤,然后拉曼分析,为复杂或干扰光谱提供了验证步骤。ICP-MS,尽管依赖于仔细和费力的样品制备,允许准确的定量结果,以估计TiO2。由于其敏感性和元素特异性,可以确定低Ti水平,但不一定表明有意添加e171。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书