Incidence and Outcomes of Flow Diverter Braid Deformation following Treatment with Non-DFT Wire Devices.

IF 1.6 4区 医学 Q2 CLINICAL NEUROLOGY
Neurologia medico-chirurgica Pub Date : 2026-07-15 Epub Date: 2026-05-27 DOI:10.2176/jns-nmc.2025-0435
Shoko Fujii, Sakyo Hirai, Kyohei Fujita, Hikaru Wakabayashi, Hirotaka Sagawa, Satoru Takahashi, Kazutaka Sumita
{"title":"Incidence and Outcomes of Flow Diverter Braid Deformation following Treatment with Non-DFT Wire Devices.","authors":"Shoko Fujii, Sakyo Hirai, Kyohei Fujita, Hikaru Wakabayashi, Hirotaka Sagawa, Satoru Takahashi, Kazutaka Sumita","doi":"10.2176/jns-nmc.2025-0435","DOIUrl":null,"url":null,"abstract":"<p><p>Flow diverter braid deformation is occasionally observed after flow diverter placement. However, the frequency and clinical significance of flow diverter braid deformation in non-drawn filled tube wire devices remain unclear. This retrospective, single-center study analyzed 139 consecutive patients (median age, 60 years; 82.7% women) who underwent flow diverter placement for intracranial aneurysms between 2017 and 2024. Follow-up angiography and cone-beam computed tomography images were compared with those obtained immediately after flow diverter deployment to identify flow diverter-related morphologic changes. The identified morphologic changes were classified into 4 major patterns (fish mouthing, bump, collapse, and shortening) as flow diverter braid deformation and 2 variants (distal tapering and edge flare) as minor morphologic changes. Cases with fish mouthing or collapse were classified as a high-risk flow diverter braid deformation category because of their association with thromboembolic complications. Flow diverter-related morphologic changes were detected in 31 patients (22.3%), including flow diverter braid deformation in 24 patients (17.3%), at the first angiographic follow-up, and no progression was detected during subsequent observations. The most common pattern was shortening (12.9%), followed by distal tapering (5.0%), and high-risk flow diverter braid deformation was rare (fish mouthing, 1.4%; collapse, 1.4%). Neointimal hyperplasia was more frequent in the flow diverter braid deformation group, whereas the rates of in-stent stenosis, aneurysm occlusion (O'Kelly-Marotta grades C-D), retreatment, and favorable functional outcomes (modified Rankin Scale, 0-2) did not differ significantly between the groups. Younger age and proximal stent oversizing were independent predictors of flow diverter braid deformation. Given the rarity of the high-risk category and the absence of adverse outcomes, flow diverter braid deformation represents a benign and stable morphological change in non-drawn filled tube wire flow diverters.</p>","PeriodicalId":19225,"journal":{"name":"Neurologia medico-chirurgica","volume":" ","pages":"456-465"},"PeriodicalIF":1.6000,"publicationDate":"2026-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC13441518/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Neurologia medico-chirurgica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2176/jns-nmc.2025-0435","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/5/27 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Flow diverter braid deformation is occasionally observed after flow diverter placement. However, the frequency and clinical significance of flow diverter braid deformation in non-drawn filled tube wire devices remain unclear. This retrospective, single-center study analyzed 139 consecutive patients (median age, 60 years; 82.7% women) who underwent flow diverter placement for intracranial aneurysms between 2017 and 2024. Follow-up angiography and cone-beam computed tomography images were compared with those obtained immediately after flow diverter deployment to identify flow diverter-related morphologic changes. The identified morphologic changes were classified into 4 major patterns (fish mouthing, bump, collapse, and shortening) as flow diverter braid deformation and 2 variants (distal tapering and edge flare) as minor morphologic changes. Cases with fish mouthing or collapse were classified as a high-risk flow diverter braid deformation category because of their association with thromboembolic complications. Flow diverter-related morphologic changes were detected in 31 patients (22.3%), including flow diverter braid deformation in 24 patients (17.3%), at the first angiographic follow-up, and no progression was detected during subsequent observations. The most common pattern was shortening (12.9%), followed by distal tapering (5.0%), and high-risk flow diverter braid deformation was rare (fish mouthing, 1.4%; collapse, 1.4%). Neointimal hyperplasia was more frequent in the flow diverter braid deformation group, whereas the rates of in-stent stenosis, aneurysm occlusion (O'Kelly-Marotta grades C-D), retreatment, and favorable functional outcomes (modified Rankin Scale, 0-2) did not differ significantly between the groups. Younger age and proximal stent oversizing were independent predictors of flow diverter braid deformation. Given the rarity of the high-risk category and the absence of adverse outcomes, flow diverter braid deformation represents a benign and stable morphological change in non-drawn filled tube wire flow diverters.

非dft金属丝装置治疗后分流器编织变形的发生率和结果。
导流器放置后,偶尔会观察到导流器编织变形。然而,在非拉伸填充管丝装置中,分流器编织变形的频率和临床意义尚不清楚。这项回顾性的单中心研究分析了2017年至2024年间接受颅内动脉瘤分流器放置的139例连续患者(中位年龄60岁,82.7%为女性)。随访血管造影和锥形束计算机断层扫描图像在分流器部署后进行比较,以确定与分流器相关的形态学变化。所识别的形态变化分为4种主要形态(鱼嘴状、凹凸、塌陷和缩短)为分流辫状变形,2种变体(远端变细和边缘闪光)为次要形态变化。由于与血栓栓塞并发症相关,出现鱼嘴或塌陷的病例被归类为高危分流器编织变形类别。在第一次血管造影随访中,31例(22.3%)患者检测到血流分流器相关的形态学改变,其中24例(17.3%)患者检测到血流分流器编织变形,在随后的观察中未发现进展。最常见的是缩短(12.9%),其次是末端变细(5.0%),高危分流器编织变形罕见(鱼嘴状,1.4%;塌陷,1.4%)。血管内膜增生在分流器编织变形组更为常见,而支架内狭窄、动脉瘤闭塞(O'Kelly-Marotta分级C-D)、再治疗和良好的功能结局(改良Rankin量表,0-2)的发生率在两组之间没有显著差异。年龄较小和近端支架尺寸过大是血流分流器编织变形的独立预测因素。考虑到高风险类别的罕见性和没有不良后果,分流器编织变形代表了非拉伸填充管丝分流器良性和稳定的形态学变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Neurologia medico-chirurgica
Neurologia medico-chirurgica 医学-临床神经学
CiteScore
3.70
自引率
10.50%
发文量
63
审稿时长
3-8 weeks
期刊介绍: Information not localized
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书