{"title":"A Label-Free Optical Biosensor Based on Ordered Porous Layer Interferometry for IgG Quantification in Milk.","authors":"Yuxin Zhai, Lu Wang, Dongmin Zhao, Huili Wang, Xiaojun Liu, Zhiping Lin, Weiping Qian","doi":"10.1093/jaoacint/qsag022","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Immunoglobulin G (IgG) levels in milk are critical indicators of dairy quality. Conventional measurement methods require labeling and complex sample pretreatment, limiting their practical use for real-time monitoring.</p><p><strong>Objective: </strong>This study aimed to develop a label-free optical biosensor based on ordered porous layer interferometry (OPLI) for the rapid quantification of IgG in milk at different processing stages.</p><p><strong>Methods: </strong>Test portions were directly applied to the flow tank, where protein A from Staphylococcus aureus was immobilized as a functional ligand via chemical conjugation. Conditions for ligand immobilization, flow rate, contact time, and sensor regeneration were optimized to minimize nonspecific binding and enhance accuracy.</p><p><strong>Results: </strong>The OPLI biosensor demonstrated a linear quantification range of 0.44 μg/mL to 5 mg/mL, with a limit of quantification of 0.44 μg/mL. This dynamic range effectively covers the IgG content from raw milk to finished milk. The method showed high reproducibility, with an instrumental response relative standard deviation (RSD) of 0.05% and an average RSD of 12.1% across batches. The biosensor was successfully applied throughout raw milk and final milk production, facilitating IgG calibration for consumer milk.</p><p><strong>Conclusion: </strong>The OPLI-based biosensor offers a sensitive, real-time and wide-range analytical method for IgG analysis, enabling effective quality control in dairy production.</p><p><strong>Highlights: </strong>The study developed a label-free biosensor for IgG detection in milk, with a linear quantification range of 0.44 μg/mL to 5 mg/mL and high reproducibility. The biosensor is applicable across all stages of dairy production for IgG quality assessment.</p>","PeriodicalId":94064,"journal":{"name":"Journal of AOAC International","volume":" ","pages":"813-818"},"PeriodicalIF":1.7000,"publicationDate":"2026-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of AOAC International","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jaoacint/qsag022","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Immunoglobulin G (IgG) levels in milk are critical indicators of dairy quality. Conventional measurement methods require labeling and complex sample pretreatment, limiting their practical use for real-time monitoring.

Objective: This study aimed to develop a label-free optical biosensor based on ordered porous layer interferometry (OPLI) for the rapid quantification of IgG in milk at different processing stages.

Methods: Test portions were directly applied to the flow tank, where protein A from Staphylococcus aureus was immobilized as a functional ligand via chemical conjugation. Conditions for ligand immobilization, flow rate, contact time, and sensor regeneration were optimized to minimize nonspecific binding and enhance accuracy.

Results: The OPLI biosensor demonstrated a linear quantification range of 0.44 μg/mL to 5 mg/mL, with a limit of quantification of 0.44 μg/mL. This dynamic range effectively covers the IgG content from raw milk to finished milk. The method showed high reproducibility, with an instrumental response relative standard deviation (RSD) of 0.05% and an average RSD of 12.1% across batches. The biosensor was successfully applied throughout raw milk and final milk production, facilitating IgG calibration for consumer milk.

Conclusion: The OPLI-based biosensor offers a sensitive, real-time and wide-range analytical method for IgG analysis, enabling effective quality control in dairy production.

Highlights: The study developed a label-free biosensor for IgG detection in milk, with a linear quantification range of 0.44 μg/mL to 5 mg/mL and high reproducibility. The biosensor is applicable across all stages of dairy production for IgG quality assessment.

基于有序多孔层干涉法的无标记光学生物传感器用于牛奶中IgG的定量。
背景:乳中免疫球蛋白G (IgG)水平是乳品质量的重要指标。传统的测量方法需要标记和复杂的样品预处理,限制了它们在实时监测中的实际应用。目的:建立一种基于有序多孔层干涉法(OPLI)的无标记光学生物传感器,用于牛奶中不同加工阶段IgG的快速定量。方法:将测试部分直接放入流动池中,通过化学偶联将金黄色葡萄球菌蛋白A固定为功能配体。优化了配体固定、流速、接触时间和传感器再生的条件,以最大限度地减少非特异性结合并提高准确性。结果:OPLI生物传感器的定量范围为0.44 μg/mL ~ 5 mg/mL,定量限为0.44 μg/mL。这个动态范围有效地涵盖了从原料奶到成品奶的IgG含量。该方法重现性好,仪器响应相对标准偏差(RSD)为0.05%,批间平均RSD为12.1%。该生物传感器成功应用于原料奶和最终奶的生产过程,促进了消费者奶IgG的校准。结论:基于opli的生物传感器为IgG分析提供了一种灵敏、实时、大范围的分析方法,能够有效地控制乳制品生产中的质量。重点:建立了牛奶中IgG无标记生物传感器,线性定量范围为0.44 μg/mL ~ 5 mg/mL,重现性高。该生物传感器适用于乳制品生产的所有阶段,用于IgG质量评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
文献相关原料
原料信息
原料厂家
1
silicone pads and microslides
2
peristaltic pump
3
inverted light microscope
4
Disodium hydrogen phosphate dodecahydrate
5
sodium dihydrogen phosphate dihydrate
6
N-hydroxysulfosuccinimide
7
bovine IgG
8
Lyophilized protein A
9
1-ethyl-3-(3-dimethylaminopropyl)carbodiimide
1892-57-5
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书