Design of a high-precision 3D measurement system via multi-source fusion and structural optimization of a Multi-Target Spatial Pose Determination Device (MSPD)

IF 6.1 2区 工程技术 Q1 ENGINEERING, MULTIDISCIPLINARY
Measurement Pub Date : 2026-05-05 Epub Date: 2026-03-06 DOI:10.1016/j.measurement.2026.121050
Han Wang , Xuejian Zhang , Zheyuan Zhang , Xiaobing Hu , Zhipeng Du
{"title":"Design of a high-precision 3D measurement system via multi-source fusion and structural optimization of a Multi-Target Spatial Pose Determination Device (MSPD)","authors":"Han Wang ,&nbsp;Xuejian Zhang ,&nbsp;Zheyuan Zhang ,&nbsp;Xiaobing Hu ,&nbsp;Zhipeng Du","doi":"10.1016/j.measurement.2026.121050","DOIUrl":null,"url":null,"abstract":"<div><div>To address the trade-off between measurement accuracy, field of view, and efficiency in large-scale dimensional metrology, this paper proposes a high-precision three-dimensional measurement method integrating a laser tracker and a binocular vision system. A Multi-Target Spatial Pose Determination Device (MSPD) is designed to establish a unified global reference frame and a stable pose linkage among heterogeneous measurement data, thereby reducing error accumulation and operational overhead in multi-station measurements. A multi-physics, multi-objective optimization model is formulated for the spatial layout of MSPD targets by incorporating geometric visibility, pose solvability, and structural constraints. The target configuration is optimized using a non-dominated sorting genetic algorithm (NSGA-II) to improve omnidirectional visibility and pose determination robustness. Experimental results show that the optimized MSPD achieves approximately 90% visibility coverage and maintains reliable target identification under varying observation poses. Calibration validation experiments yield a mean reprojection error of 0.1331 mm, confirming the accuracy and repeatability of the coordinate transformation and pose prediction models. Comparative multi-station experiments further demonstrate that, with only one initial calibration, the proposed MSPD-based tracking integration strategy achieves an average point position error of 0.3336 mm and a closed-loop consistency error of 0.2363 mm, while limiting additional operation time per station to 1–2 min. In contrast, station-by-station repeated calibration requires 15–20 min per station, and feature-based alignment exhibits significant error accumulation. These results indicate that the proposed fusion measurement framework provides an effective balance between accuracy, robustness, and operational efficiency, making it suitable for engineering-scale measurement of large and complex components and high-precision robotic calibration.</div></div>","PeriodicalId":18349,"journal":{"name":"Measurement","volume":"272 ","pages":"Article 121050"},"PeriodicalIF":6.1000,"publicationDate":"2026-05-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measurement","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0263224126007591","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2026/3/6 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

To address the trade-off between measurement accuracy, field of view, and efficiency in large-scale dimensional metrology, this paper proposes a high-precision three-dimensional measurement method integrating a laser tracker and a binocular vision system. A Multi-Target Spatial Pose Determination Device (MSPD) is designed to establish a unified global reference frame and a stable pose linkage among heterogeneous measurement data, thereby reducing error accumulation and operational overhead in multi-station measurements. A multi-physics, multi-objective optimization model is formulated for the spatial layout of MSPD targets by incorporating geometric visibility, pose solvability, and structural constraints. The target configuration is optimized using a non-dominated sorting genetic algorithm (NSGA-II) to improve omnidirectional visibility and pose determination robustness. Experimental results show that the optimized MSPD achieves approximately 90% visibility coverage and maintains reliable target identification under varying observation poses. Calibration validation experiments yield a mean reprojection error of 0.1331 mm, confirming the accuracy and repeatability of the coordinate transformation and pose prediction models. Comparative multi-station experiments further demonstrate that, with only one initial calibration, the proposed MSPD-based tracking integration strategy achieves an average point position error of 0.3336 mm and a closed-loop consistency error of 0.2363 mm, while limiting additional operation time per station to 1–2 min. In contrast, station-by-station repeated calibration requires 15–20 min per station, and feature-based alignment exhibits significant error accumulation. These results indicate that the proposed fusion measurement framework provides an effective balance between accuracy, robustness, and operational efficiency, making it suitable for engineering-scale measurement of large and complex components and high-precision robotic calibration.
基于多源融合和结构优化的多目标空间姿态确定装置(MSPD)高精度三维测量系统设计
为了解决大尺寸测量中测量精度、视场和效率之间的权衡问题,本文提出了一种激光跟踪仪与双目视觉系统相结合的高精度三维测量方法。设计了一种多目标空间位姿确定装置(MSPD),在异构测量数据之间建立统一的全局参考框架和稳定的位姿链接,从而减少多站测量中的误差积累和操作开销。结合几何可见性、姿态可解性和结构约束,建立了MSPD目标空间布局的多物理场、多目标优化模型。采用非支配排序遗传算法(NSGA-II)对目标构型进行优化,提高了目标的全向可见性和姿态确定的鲁棒性。实验结果表明,优化后的MSPD在不同的观测姿态下均能实现约90%的可见覆盖率,并保持可靠的目标识别。标定验证实验的平均重投影误差为0.1331 mm,验证了坐标变换和位姿预测模型的准确性和可重复性。多站对比实验进一步表明,在初始标定1次的情况下,基于mspd的跟踪集成策略的平均点位误差为0.3336 mm,闭环一致性误差为0.2363 mm,同时将每站的额外操作时间限制在1 ~ 2 min。相比之下,逐站重复校准每个站点需要15-20分钟,并且基于特征的校准具有显着的误差积累。结果表明,所提出的融合测量框架在精度、鲁棒性和运行效率之间取得了有效的平衡,适用于大型复杂部件的工程尺度测量和高精度机器人标定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Measurement
Measurement 工程技术-工程:综合
CiteScore
10.20
自引率
12.50%
发文量
1589
审稿时长
12.1 months
期刊介绍: Contributions are invited on novel achievements in all fields of measurement and instrumentation science and technology. Authors are encouraged to submit novel material, whose ultimate goal is an advancement in the state of the art of: measurement and metrology fundamentals, sensors, measurement instruments, measurement and estimation techniques, measurement data processing and fusion algorithms, evaluation procedures and methodologies for plants and industrial processes, performance analysis of systems, processes and algorithms, mathematical models for measurement-oriented purposes, distributed measurement systems in a connected world.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书